Cali-GrafCali-Graf
Solar panelSonali Energees

Sonali Energees SS120H-360MB

120 half-cut cells. Power classes 310–455 W in the CEC list.

CEC listed · Aug 21, 2024UL 61730
Power class
  • Power (STC)360 WCEC nameplate
  • Efficiency≈19.8%calculated from area
  • %/°C Pmax−0.375CEC listing test
  • PTC / STC93.4%PTC 336 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 17 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
SS120H-310MB310 W39.809.8733.109.37≈18.3%289 WAug 21, 2024
SS120H-315MB315 W40.109.9533.409.44≈18.6%294 WAug 21, 2024
SS120H-320MB320 W40.4010.0133.609.52≈18.9%298 WAug 21, 2024
SS120H-325MB325 W40.7010.0833.909.59≈19.2%303 WAug 21, 2024
SS120H-330MB330 W41.0010.1634.209.66≈19.5%308 WAug 21, 2024
SS120H-335MB335 W41.2010.3534.409.75≈19.8%313 WAug 21, 2024
SS120H-340MB340 W41.4010.4434.609.82≈20.1%318 WAug 21, 2024
SS120H-355MB355 W41.3011.0833.8010.51≈19.5%331 WAug 21, 2024
SS120H-360MB360 W41.5011.1534.0010.59≈19.8%336 WAug 21, 2024
SS120H-365MB365 W41.7011.2234.2010.68≈20.1%341 WAug 21, 2024
SS120H-370MB370 W41.9011.2934.4010.76≈20.3%346 WAug 21, 2024
SS120H-375MB375 W42.1011.3634.6010.84≈20.6%351 WAug 21, 2024
SS120H-435MB435 W41.0013.6733.6012.96≈20.1%408 WAug 21, 2024
SS120H-440MB440 W41.0013.7333.7013.05≈20.4%412 WAug 21, 2024
SS120H-445MB445 W41.1013.7933.8013.16≈20.6%417 WAug 21, 2024
SS120H-450MB450 W41.2013.8533.9013.27≈20.8%422 WAug 21, 2024
SS120H-455MB455 W41.3013.9334.1013.36≈21.1%427 WAug 21, 2024
≈ efficiency = Pmax ÷ CEC-listed area 1.69 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.375 %/°C
Voc coefficient β−0.282 %/°C
Isc coefficient α+0.067 %/°C
Operating cell temperatureNOCT 43.2 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
310 W234 W31.2 V × 7.5 A58.6 W94%
315 W238.1 W31.5 V × 7.56 A59.4 W94%
320 W241.6 W31.7 V × 7.62 A60.4 W94%
325 W245.8 W32 V × 7.68 A61.3 W94%
330 W249.7 W32.3 V × 7.73 A62.5 W95%
335 W253.8 W32.5 V × 7.81 A63.5 W95%
340 W256.2 W32.6 V × 7.86 A64.2 W94%
355 W269.3 W32.1 V × 8.39 A68.5 W96%
360 W273.3 W32.3 V × 8.46 A69.5 W97%
365 W277.2 W32.5 V × 8.53 A70.3 W96%
370 W280 W32.6 V × 8.59 A71.3 W96%
375 W284 W32.8 V × 8.66 A72.4 W97%
435 W321 W31.2 V × 10.29 A84.1 W97%
440 W323.2 W31.2 V × 10.36 A84.7 W96%
445 W326.8 W31.3 V × 10.44 A85.6 W96%
450 W330.6 W31.4 V × 10.53 A86.8 W96%
455 W335 W31.6 V × 10.6 A87.5 W96%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
44.2 V
Voc when cold
per panel
26.6 V
Vmp when hot
per panel
13
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–13
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet4–13
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–13
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window9–11

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V44.2 / 26.6 V⚠ Works; below MPPT at peak heat1.24
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V44.2 / 26.6 V✗ Not a match: module voltage below MPPT range0.95
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V44.2 / 26.6 V⚠ Works; below MPPT at peak heat0.46
Enphase IQ8M-72-2-US260–460 W60 V30–45 V44.2 / 26.6 V⚠ Works; below MPPT at peak heat1.11
Enphase IQ8A-72-2-US295–500 W60 V32–45 V44.2 / 26.6 V⚠ Works; below MPPT at peak heat1.03
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67660311,4646.08
Palmdale1,83566112,5516.69
Chula Vista1,69661111,6016.11
Huntington Beach1,64359111,2385.89
Riverside1,69661111,6016.21
Santa Clarita1,72462111,7926.28
748Jan749Feb961Mar1,062Apr1,049May1,114Jun1,174Jul1,187Aug1,038Sep916Oct787Nov681DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 360 W panels

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
Sonali Energees SS120H-360MB360 W≈19.8%−0.37541.511.15——
LONGi LR4-60HPB-360M360 W≈20.3%−0.33940.811.33product 2021, 2022193
REC Group REC360AA360 W≈21.4%−0.27944.110.23brand 9× (2016–2025)30
Trina Solar TSM-360DE06X.05(II)360 W≈19.8%−0.33944.810.3product 202223
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the Sonali Energees SS120H-360MB?

Calculated from the panel area (1.82 m²): about 19.8% for the 360 W class. 360 W over 1.82 m² equals about 198 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 603 kWh per year per 360 W panel in Los Angeles and about 661 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.375 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 19.4% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–13 panels per string (Voc at 2 °C = 44.2 V, Vmp at 74 °C cell = 26.6 V). Final design must follow the inverter manual and NEC 690.7.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
  3. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  4. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  5. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  6. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  7. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).