Cali-GrafCali-Graf
Solar panelSonali Energees

Sonali Energees SS120H-340M

120 half-cut cells. Power classes 310–375 W in the CEC list.

CEC listed · Aug 21, 2024UL 61730
Power class
  • Power (STC)340 WCEC nameplate
  • Efficiency≈20.1%calculated from area
  • %/°C Pmax−0.379CEC listing test
  • PTC / STC93.4%PTC 318 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 13 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
SS120H-310M310 W39.809.8733.109.37≈18.3%289 WAug 21, 2024
SS120H-315M315 W40.109.9533.409.44≈18.6%294 WAug 21, 2024
SS120H-320M320 W40.4010.0133.609.52≈18.9%298 WAug 21, 2024
SS120H-325M325 W40.7010.0833.909.59≈19.2%303 WAug 21, 2024
SS120H-330M330 W41.0010.1634.209.66≈19.5%308 WAug 21, 2024
SS120H-335M335 W41.2010.3534.409.75≈19.8%313 WAug 21, 2024
SS120H-340M340 W41.4010.4434.609.82≈20.1%318 WAug 21, 2024
SS120H-350M350 W41.1011.0133.6010.42≈19.2%327 WAug 21, 2024
SS120H-355M355 W41.3011.0833.8010.51≈19.5%331 WAug 21, 2024
SS120H-360M360 W41.5011.1534.0010.59≈19.8%336 WAug 21, 2024
SS120H-365M365 W41.7011.2234.2010.68≈20.1%341 WAug 21, 2024
SS120H-370M370 W41.9011.2934.4010.76≈20.3%346 WAug 21, 2024
SS120H-375M375 W42.1011.3634.6010.84≈20.6%351 WAug 21, 2024
≈ efficiency = Pmax ÷ CEC-listed area 1.69 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.379 %/°C
Voc coefficient β−0.319 %/°C
Isc coefficient α+0.045 %/°C
Operating cell temperatureNOCT 43.1 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
310 W234 W31.2 V × 7.5 A58.6 W94%
315 W238.1 W31.5 V × 7.56 A59.4 W94%
320 W241.6 W31.7 V × 7.62 A60.4 W94%
325 W245.8 W32 V × 7.68 A61.3 W94%
330 W249.7 W32.3 V × 7.73 A62.5 W95%
335 W253.8 W32.5 V × 7.81 A63.5 W95%
340 W256.2 W32.6 V × 7.86 A64.2 W94%
350 W265.4 W31.9 V × 8.32 A67.4 W96%
355 W269.3 W32.1 V × 8.39 A68.5 W96%
360 W273.3 W32.3 V × 8.46 A69.5 W97%
365 W277.2 W32.5 V × 8.53 A70.3 W96%
370 W280 W32.6 V × 8.59 A71.3 W96%
375 W284 W32.8 V × 8.66 A72.4 W97%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
44.4 V
Voc when cold
per panel
27.4 V
Vmp when hot
per panel
13
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–13
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–13
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–13
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window9–11

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V44.4 / 27.4 V⚠ Works; below MPPT at peak heat1.17
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V44.4 / 27.4 V✗ Not a match: module voltage below MPPT range0.89
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V44.4 / 27.4 V⚠ Works; below MPPT at peak heat0.44
Enphase IQ8M-72-2-US260–460 W60 V30–45 V44.4 / 27.4 V⚠ Works; below MPPT at peak heat1.05
Enphase IQ8A-72-2-US295–500 W60 V32–45 V44.4 / 27.4 V⚠ Works; below MPPT at peak heat0.97
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67657011,9676.08
Palmdale1,83562413,1026.69
Chula Vista1,69657712,1096.11
Huntington Beach1,64355911,7315.89
Riverside1,69657712,1096.21
Santa Clarita1,72458612,3096.28
781Jan782Feb1,003Mar1,108Apr1,095May1,163Jun1,225Jul1,240Aug1,084Sep956Oct822Nov711DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 340 W panels

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · JinkoSolar datasheets · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
Sonali Energees SS120H-340M340 W≈20.1%−0.37941.410.44——
LONGi LR4-60HPB-340M340 W≈18.8%−0.33740.110.84product 2021, 2022193
JinkoSolar JKM340M-60HBL340 W≈20.1%−0.4064110.82brand 12× (2014–2026)45
REC Group REC340AA340 W≈20.2%−0.27943.110.09brand 9× (2016–2025)30
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the Sonali Energees SS120H-340M?

Calculated from the panel area (1.69 m²): about 20.1% for the 340 W class. 340 W over 1.69 m² equals about 201 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 570 kWh per year per 340 W panel in Los Angeles and about 624 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.379 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 19.6% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–13 panels per string (Voc at 2 °C = 44.4 V, Vmp at 74 °C cell = 27.4 V). Final design must follow the inverter manual and NEC 690.7.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. JinkoSolar — datasheet THE MOST DEPENDABLE SOLAR BRAND.
  3. JinkoSolar — manufacturer datasheet “Eagle HC 60M G2 315-335 Watt MONO PERC HALF CELL MODULE”.
  4. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
  5. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  6. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  7. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  8. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  9. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).