60 cells. Power classes 270–350 W in the CEC list.

CEC listed · Jul 21, 2020UL 61730
Power class
  • Power (STC)315 WCEC nameplate
  • Efficiency≈16.4%calculated from area
  • %/°C Pmax−0.439CEC listing test
  • PTC / STC91.6%PTC 288 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 17 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
SS 270270 W43.208.0536.007.50≈14.2%233 W—
SS-270270 W38.009.2031.608.55≈16.7%245 WJul 21, 2020
SS-275275 W38.159.2531.808.65≈17.0%250 WJul 21, 2020
SS 280280 W43.928.1536.587.66≈14.7%242 W—
SS-280280 W38.309.3532.008.75≈17.3%254 WJul 21, 2020
SS 290290 W43.928.3036.727.90≈15.2%251 W—
SS 300300 W44.648.4537.587.98≈15.7%274 W—
SS 310310 W45.368.5537.908.17≈16.2%284 W—
SS 315315 W45.728.5938.108.27≈16.4%288 W—
SS 320320 W46.088.6238.308.36≈16.7%293 W—
SS-320320 W46.509.1537.658.50≈16.7%289 WJul 21, 2020
SS-325325 W46.609.2037.808.60≈16.9%293 WJul 21, 2020
SS-330330 W46.709.2537.958.70≈17.2%298 WJul 21, 2020
SS-335335 W46.809.3038.108.80≈17.4%303 WJul 21, 2020
SS-340340 W46.909.3538.258.90≈17.7%310 WJul 21, 2020
SS-345345 W47.009.4038.558.95≈18.0%314 WJul 21, 2020
SS-350350 W47.109.4538.909.00≈18.2%319 WJul 21, 2020
≈ efficiency = Pmax ÷ CEC-listed area 1.91 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.439 %/°C
Voc coefficient β−0.331 %/°C
Isc coefficient α+0.065 %/°C
Vmp coefficient−0.202 %/°C
Operating cell temperatureNOCT 43.7 °C

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
270 W190.7 W30.89 V × 6.18 A52.7 W98%
270 W197.6 W29.01 V × 6.81 A50.2 W93%
275 W201.1 W29.19 V × 6.89 A50.8 W92%
280 W197.9 W31.38 V × 6.31 A54.7 W98%
280 W204.7 W29.37 V × 6.97 A51.8 W92%
290 W204.9 W31.5 V × 6.5 A56.6 W98%
300 W201.7 W33.62 V × 6 A57.8 W96%
310 W208.3 W33.91 V × 6.14 A59.5 W96%
315 W212 W34.09 V × 6.22 A60.6 W96%
320 W215.4 W34.27 V × 6.29 A61.5 W96%
320 W235.6 W34.5 V × 6.83 A59.4 W93%
325 W239.1 W34.6 V × 6.91 A60 W92%
330 W243.3 W34.8 V × 6.99 A61 W92%
335 W246.7 W34.9 V × 7.07 A62 W93%
340 W251 W35.3 V × 7.11 A65.5 W96%
345 W253.8 W35.5 V × 7.15 A66.4 W96%
350 W258.1 W35.9 V × 7.19 A67.4 W96%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
49.2 V
Voc when cold
per panel
34.3 V
Vmp when hot
per panel
12
Max panels / string
max DC 600 V
2
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet2–12
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–12
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet3–12
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window7–10

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V49.2 / 34.3 V✓ Within range1.09
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V49.2 / 34.3 V✓ Within range0.4
Enphase IQ8M-72-2-US260–460 W60 V30–45 V49.2 / 34.3 V✓ Within range0.97
Enphase IQ8A-72-2-US295–500 W60 V32–45 V49.2 / 34.3 V✓ Within range0.9
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67652811,6156.08
Palmdale1,83557812,7176.69
Chula Vista1,69653411,7536.11
Huntington Beach1,64351811,3865.89
Riverside1,69653411,7536.21
Santa Clarita1,72454311,9476.28
758Jan759Feb974Mar1,076Apr1,062May1,129Jun1,189Jul1,203Aug1,052Sep928Oct798Nov690DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 315 W panels

CEC PV Module List (Oct 7, 2026) · datasheets · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, ASizePVEL (product / brand)SoCal permits (series)
Sonali Energees SS 315315 W≈16.4%−0.43945.728.5976.9 in——
JinkoSolar JKM315M-60HBL315 W≈18.7%−0.40740.710.0466.3 × 39.4 inbrand 12× (2014–2026)45
LG Electronics LG320N1C-N5320 W≈18.5%−0.34240.810.5366.9 × 40 inproduct 20215
REC Group REC315NP315 W≈19.4%−0.35140.510.09—brand 9× (2016–2025)4
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the Sonali Energees SS 315?

Calculated from the panel area (1.91 m²): about 16.4% for the 315 W class. 315 W over 1.91 m² equals about 165 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 528 kWh per year per 315 W panel in Los Angeles and about 578 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.439 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 22.7% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–12 panels per string (Voc at 2 °C = 49.2 V, Vmp at 74 °C cell = 34.3 V). Final design must follow the inverter manual and NEC 690.7.

Does it work with Enphase IQ8PLUS-72-2-US microinverters?

Voltage check against the Enphase datasheet: Voc when cold 49.2 V vs max input 60 V; Vmp when hot 34.3 V vs MPPT low 29 V; recommended module power 235–440 W. Confirm on the microinverter maker’s compatibility list.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. JinkoSolar — datasheet THE MOST DEPENDABLE SOLAR BRAND.
  3. JinkoSolar — manufacturer datasheet “Eagle HC 60M G2 315-335 Watt MONO PERC HALF CELL MODULE”.
  4. LG Electronics — datasheet Specification Sheet.
  5. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
  6. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  7. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.