CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
Model
Pmax
Voc, V
Isc, A
Vmp, V
Imp, A
Efficiency
PTC
CEC listed
SV50-225 E BC2 Kromatix Bronze
225 W
33.61
8.63
27.55
8.20
≈13.7%
204 W
Aug 11, 2023
≈ efficiency = Pmax ÷ CEC-listed area 1.64 m².
Build & dimensions
CEC PV Module List (Oct 7, 2026)
Module area1.64 m² (17.7 ft²)CEC-listed area
Cells50 cells
Back coverBlack backsheet
Heat & cold behaviour
CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ
−0.397 %/°C
Voc coefficient β
−0.290 %/°C
Isc coefficient α
+0.029 %/°C
Operating cell temperature
NOCT 46.6 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.
Away from lab conditions — CEC listing test points
Class
Pmax at NOCT
Vmp × Imp at NOCT
Pmax at 200 W/m²
Low-light efficiency vs STC
225 W
162.9 W
24.61 V × 6.62 A
44.9 W
100%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).
Certifications
CEC PV Module List (Oct 7, 2026)
UL 61730IEC 61215
UL 61730CEC listing
IEC 61215design qualification on file with CEC · Mar 15, 2023
Inverter compatibility & string sizing
CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
35.9 V
Voc when cold
per panel
21.8 V
Vmp when hot
per panel
16
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.
String inverters most named in SoCal permits
Inverter
Max DC input
MPPT
Window source
Panels per string
Tesla 1538000-xx-y
600 V
60–480 V
datasheet
3–16
Solis (Ginlong) S6-EH1P10K-H-US
600 V
80–520 V
datasheet
4–16
Solis (Ginlong) Solis-1P7.6K-4G-US
600 V
100–500 V
datasheet
5–16
Qcells Q.VOLT H7.6SX
498 V
234–498 V
CEC test window
11–13
Microinverters (one per panel)
No microinverter in the reference set lists this power class in its recommended module power range.
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.
Expected production in Southern California
NLR PVWatts v8 · Cali-Graf calculation
City
kWh / kW / yr
kWh / panel / yr
kWh / system / yr
Sun, kWh/m²/day
Los Angeles
1,676
377
11,313
6.08
Palmdale
1,835
413
12,386
6.69
Chula Vista
1,696
382
11,448
6.11
Huntington Beach
1,643
370
11,090
5.89
Riverside
1,696
382
11,448
6.21
Santa Clarita
1,724
388
11,637
6.28
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.
Questions & answers
How efficient is the SOLVIS SV50-225 E BC2 Kromatix Bronze?
Calculated from the panel area (1.64 m²): about 13.7% for the 225 W class. 225 W over 1.64 m² equals about 137 W per square meter.
How much energy does one panel produce in Los Angeles or Palmdale?
PVWatts v8 with typical-year weather gives about 377 kWh per year per 225 W panel in Los Angeles and about 413 kWh in Palmdale (20° roof, facing south, 14% system losses).
How much power does it lose on a hot roof?
With γ = −0.397 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 20.6% below the STC rating.
How many panels fit on one string?
With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–16 panels per string (Voc at 2 °C = 35.9 V, Vmp at 74 °C cell = 21.8 V). Final design must follow the inverter manual and NEC 690.7.
Sources
California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
Inverter datasheets — Solis (Ginlong), Tesla (manufacturer documents).
Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).
Get your free estimate
Three fields, and Cali Energy calls back within 30 minutes during business hours.
Thanks!
We got your request and will call back within 30 minutes during business hours.