144 half-cut cells. Power classes 520–560 W in the CEC list.
| Model | Pmax | Voc, V | Isc, A | Vmp, V | Imp, A | Efficiency | PTC | CEC listed |
|---|---|---|---|---|---|---|---|---|
| SMF72HM10-520 | 520 W | 49.19 | 13.27 | 41.28 | 12.60 | ≈20.2% | 487 W | Jul 21, 2023 |
| SMF72HM10-525 | 525 W | 49.32 | 13.35 | 41.41 | 12.68 | ≈20.3% | 491 W | Jul 21, 2023 |
| SMF72HM10-530 | 530 W | 49.45 | 13.43 | 41.54 | 12.76 | ≈20.5% | 496 W | Jul 21, 2023 |
| SMF72HM10-535 | 535 W | 49.58 | 13.51 | 41.67 | 12.84 | ≈20.7% | 501 W | Jul 21, 2023 |
| SMF72HM10-540 | 540 W | 49.71 | 13.59 | 41.80 | 12.92 | ≈20.9% | 506 W | Jul 21, 2023 |
| SMF72HM10-545 | 545 W | 49.84 | 13.67 | 41.93 | 13.00 | ≈21.1% | 511 W | Jul 21, 2023 |
| SMF72HM10-550 | 550 W | 49.97 | 13.75 | 42.06 | 13.08 | ≈21.3% | 515 W | Jul 21, 2023 |
| SMF72HM10-555 | 555 W | 50.10 | 13.83 | 42.19 | 13.16 | ≈21.5% | 520 W | Jul 21, 2023 |
| SMF72HM10-560 | 560 W | 50.23 | 13.91 | 42.33 | 13.23 | ≈21.7% | 525 W | Jul 21, 2023 |
| CEC listing test | |
|---|---|
| Pmax coefficient γ | −0.315 %/°C |
| Voc coefficient β | −0.234 %/°C |
| Isc coefficient α | +0.028 %/°C |
| Operating cell temperature | NOCT 46.2 °C |
| Class | Pmax at NOCT | Vmp × Imp at NOCT | Pmax at 200 W/m² | Low-light efficiency vs STC |
|---|---|---|---|---|
| 520 W | 383.8 W | 38.4 V × 10 A | 102 W | 98% |
| 525 W | 387.5 W | 38.52 V × 10.06 A | 103 W | 98% |
| 530 W | 391.1 W | 38.64 V × 10.12 A | 104 W | 98% |
| 535 W | 394.8 W | 38.76 V × 10.19 A | 105 W | 98% |
| 540 W | 398.5 W | 38.88 V × 10.25 A | 105.9 W | 98% |
| 545 W | 402.2 W | 39 V × 10.31 A | 106.9 W | 98% |
| 550 W | 406 W | 39.12 V × 10.38 A | 107.9 W | 98% |
| 555 W | 409.7 W | 39.24 V × 10.44 A | 108.9 W | 98% |
| 560 W | 413.3 W | 39.37 V × 10.5 A | 109.9 W | 98% |
| Inverter | Max DC input | MPPT | Window source | Panels per string |
|---|---|---|---|---|
| Tesla 1538000-xx-y | 600 V | 60–480 V | datasheet | 2–11 |
| Solis (Ginlong) S6-EH1P10K-H-US | 600 V | 80–520 V | datasheet | 3–11 |
| Solis (Ginlong) Solis-1P7.6K-4G-US | 600 V | 100–500 V | datasheet | 3–11 |
| Qcells Q.VOLT H7.6SX | 498 V | 234–498 V | CEC test window | 7–9 |
| Microinverter | Recommended module power | Max DC input | MPPT | Voc cold / Vmp hot | Check | DC/AC |
|---|---|---|---|---|---|---|
| Enphase IQ8X-80-M-US | 320–540 W | 79.5 V | 43–60 V | 52.4 / 34.8 V | ✗ Not a match: module voltage below MPPT range | 1.42 |
| APsystems (Alt Power System) DS3-L | 265–570 W | 60 V | 28–45 V | 52.4 / 34.8 V | ✓ Within range | 0.69 |
| City | kWh / kW / yr | kWh / panel / yr | kWh / system / yr | Sun, kWh/m²/day |
|---|---|---|---|---|
| Los Angeles | 1,676 | 905 | 11,766 | 6.08 |
| Palmdale | 1,835 | 991 | 12,882 | 6.69 |
| Chula Vista | 1,696 | 916 | 11,906 | 6.11 |
| Huntington Beach | 1,643 | 887 | 11,534 | 5.89 |
| Riverside | 1,696 | 916 | 11,906 | 6.21 |
| Santa Clarita | 1,724 | 931 | 12,102 | 6.28 |
| Panel | Pmax | Efficiency | γ Pmax (CEC) | Voc, V | Isc, A | PVEL (product / brand) | SoCal permits (series) |
|---|---|---|---|---|---|---|---|
| SOLEX ENERGY SMF72HM10 540 | 540 W | ≈20.9% | −0.315 | 49.71 | 13.59 | brand 1× | — |
| JA Solar JAM72D30-540/MB | 540 W | ≈21.4% | −0.330 | 49.6 | 13.86 | product 2023, 2024 | 3 |
| Canadian Solar CS6W-540MB-AG | 540 W | ≈21% | −0.324 | 49.2 | 13.9 | product 2024 | 1 |
| LONGi LR5-72HBD-540M | 540 W | ≥21.1% | −0.354 | 49.5 | 13.85 | product 2026 | 1 |
Calculated from the panel area (2.58 m²): about 20.9% for the 540 W class. 540 W over 2.58 m² equals about 209 W per square meter.
PVWatts v8 with typical-year weather gives about 905 kWh per year per 540 W panel in Los Angeles and about 991 kWh in Palmdale (20° roof, facing south, 14% system losses).
With γ = −0.315 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 16.3% below the STC rating.
With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–11 panels per string (Voc at 2 °C = 52.4 V, Vmp at 74 °C cell = 34.8 V). Final design must follow the inverter manual and NEC 690.7.
Voltage check against the APsystems (Alt Power System) datasheet: Voc when cold 52.4 V vs max input 60 V; Vmp when hot 34.8 V vs MPPT low 28 V; recommended module power 265–570 W. Confirm on the microinverter maker’s compatibility list.
This exact series is not in published PVEL Top Performer tables; SOLEX ENERGY was named a Top Performer in 1 Scorecard (2026).