144 half-cut cells, bifacial. Power classes 430–465 W in the CEC list.
| Model | Pmax | Voc, V | Isc, A | Vmp, V | Imp, A | Efficiency | PTC | CEC listed |
|---|---|---|---|---|---|---|---|---|
| SMB60HM10-430 | 430 W | 41.33 | 13.18 | 34.23 | 12.57 | ≈19.8% | 400 W | Oct 2, 2023 |
| SMB60HM10-435 | 435 W | 41.50 | 13.26 | 34.40 | 12.65 | ≈20.0% | 405 W | Oct 2, 2023 |
| SMB60HM10-440 | 440 W | 41.67 | 13.34 | 34.57 | 12.73 | ≈20.3% | 410 W | Oct 2, 2023 |
| SMB60HM10-445 | 445 W | 41.84 | 13.43 | 34.74 | 12.81 | ≈20.5% | 414 W | Oct 2, 2023 |
| SMB60HM10-450 | 450 W | 41.99 | 13.52 | 34.89 | 12.90 | ≈20.7% | 419 W | Oct 2, 2023 |
| SMB60HM10-455 | 455 W | 42.16 | 13.60 | 35.06 | 12.98 | ≈21.0% | 424 W | Oct 2, 2023 |
| SMB60HM10-460 | 460 W | 42.31 | 13.69 | 35.21 | 13.07 | ≈21.2% | 429 W | Oct 2, 2023 |
| SMB60HM10-465 | 465 W | 42.44 | 13.78 | 35.34 | 13.16 | ≈21.4% | 434 W | Oct 2, 2023 |
| CEC listing test | |
|---|---|
| Pmax coefficient γ | −0.305 %/°C |
| Voc coefficient β | −0.228 %/°C |
| Isc coefficient α | +0.017 %/°C |
| Operating cell temperature | NOCT 48.5 °C |
| Class | Pmax at NOCT | Vmp × Imp at NOCT | Pmax at 200 W/m² | Low-light efficiency vs STC |
|---|---|---|---|---|
| 430 W | 326.4 W | 32.2 V × 10.14 A | 88.1 W | 102% |
| 435 W | 330.1 W | 32.36 V × 10.2 A | 89.1 W | 102% |
| 440 W | 333.8 W | 32.52 V × 10.27 A | 90.1 W | 102% |
| 445 W | 337.6 W | 32.68 V × 10.33 A | 91.2 W | 102% |
| 450 W | 341.4 W | 32.82 V × 10.4 A | 92.2 W | 102% |
| 455 W | 345.2 W | 32.98 V × 10.47 A | 93.2 W | 102% |
| 460 W | 349.1 W | 33.12 V × 10.54 A | 94.3 W | 102% |
| 465 W | 352.8 W | 33.24 V × 10.61 A | 95.3 W | 102% |
| Inverter | Max DC input | MPPT | Window source | Panels per string |
|---|---|---|---|---|
| Tesla 1538000-xx-y | 600 V | 60–480 V | datasheet | 3–13 |
| Solis (Ginlong) S6-EH1P10K-H-US | 600 V | 80–520 V | datasheet | 3–13 |
| Solis (Ginlong) Solis-1P7.6K-4G-US | 600 V | 100–500 V | datasheet | 4–13 |
| Qcells Q.VOLT H7.6SX | 498 V | 234–498 V | CEC test window | 9–11 |
| Microinverter | Recommended module power | Max DC input | MPPT | Voc cold / Vmp hot | Check | DC/AC |
|---|---|---|---|---|---|---|
| Enphase IQ8X-80-M-US | 320–540 W | 79.5 V | 43–60 V | 44 / 29.2 V | ✗ Not a match: module voltage below MPPT range | 1.17 |
| APsystems (Alt Power System) DS3-L | 265–570 W | 60 V | 28–45 V | 44 / 29.2 V | ✓ Within range | 0.57 |
| Enphase IQ8M-72-2-US | 260–460 W | 60 V | 30–45 V | 44 / 29.2 V | ⚠ Works; below MPPT at peak heat | 1.37 |
| Enphase IQ8A-72-2-US | 295–500 W | 60 V | 32–45 V | 44 / 29.2 V | ⚠ Works; below MPPT at peak heat | 1.28 |
| City | kWh / kW / yr | kWh / panel / yr | kWh / system / yr | Sun, kWh/m²/day |
|---|---|---|---|---|
| Los Angeles | 1,676 | 746 | 11,933 | 6.08 |
| Palmdale | 1,835 | 817 | 13,065 | 6.69 |
| Chula Vista | 1,696 | 755 | 12,076 | 6.11 |
| Huntington Beach | 1,643 | 731 | 11,698 | 5.89 |
| Riverside | 1,696 | 755 | 12,076 | 6.21 |
| Santa Clarita | 1,724 | 767 | 12,275 | 6.28 |
| Panel | Pmax | Efficiency | γ Pmax (CEC) | Voc, V | Isc, A | Warranty | PVEL (product / brand) | SoCal permits (series) |
|---|---|---|---|---|---|---|---|---|
| SOLEX ENERGY SMB60HM10 445 | 445 W | ≈20.5% | −0.305 | 41.84 | 13.43 | — | brand 1× | — |
| Qcells Q.TRON BLK M-G2+ 445 | 445 W | ≈22.8% | −0.276 | 40.16 | 13.98 | 25 / 25 yr | brand 11× (2016–2026) | 40 |
| Silfab Solar SIL-440QD | 440 W | ≈22.6% | −0.294 | 38.97 | 14.25 | 25 / 30 yr | brand 7× (2017–2025) | 39 |
| Hyundai Energy Solutions HiN-T445NF(BK) | 445 W | ≈22.9% | −0.298 | 39 | 14.46 | 25 / 30 yr | brand 5× (2017–2025) | 37 |
Calculated from the panel area (2.17 m²): about 20.5% for the 445 W class. 445 W over 2.17 m² equals about 205 W per square meter.
PVWatts v8 with typical-year weather gives about 746 kWh per year per 445 W panel in Los Angeles and about 817 kWh in Palmdale (20° roof, facing south, 14% system losses).
With γ = −0.305 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 15.8% below the STC rating.
With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–13 panels per string (Voc at 2 °C = 44 V, Vmp at 74 °C cell = 29.2 V). Final design must follow the inverter manual and NEC 690.7.
Voltage check against the APsystems (Alt Power System) datasheet: Voc when cold 44 V vs max input 60 V; Vmp when hot 29.2 V vs MPPT low 28 V; recommended module power 265–570 W. Confirm on the microinverter maker’s compatibility list.
Yes. Rear gain depends on mounting height and ground reflectance.
This exact series is not in published PVEL Top Performer tables; SOLEX ENERGY was named a Top Performer in 1 Scorecard (2026).