Solar panelSolarJuice American

SolarJuice American S4AI-144S-530C

144 half-cut cells. Power classes 435–550 W in the CEC list.

CEC listed · Jun 13, 2022UL 61730
Power class
  • Power (STC)530 WCEC nameplate
  • Efficiency≈20.5%calculated from area
  • %/°C Pmax−0.373CEC listing test
  • PTC / STC92.5%PTC 490 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 9 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
S4AI-144S-435C435 W49.6011.5340.7010.70≈20.0%408 WJun 13, 2022
S4AI-144S-440C440 W49.8011.6040.9010.77≈20.3%413 WJun 13, 2022
S4AI-144S-445C445 W49.9011.7241.0010.86≈20.5%418 WJun 13, 2022
S4AI-144S-450C450 W50.0011.8341.1010.96≈20.7%422 WJun 13, 2022
S4AI-144S-530C530 W49.2013.7641.3512.83≈20.5%490 WJun 13, 2022
S4AI-144S-535C535 W49.3513.8341.5012.90≈20.7%495 WJun 13, 2022
S4AI-144S-540C540 W49.5013.9041.6512.97≈20.9%500 WJun 13, 2022
S4AI-144S-545C545 W49.6513.9541.8013.05≈21.1%505 WJun 13, 2022
S4AI-144S-550C550 W49.8014.0041.9513.12≈21.2%510 WJun 13, 2022
≈ efficiency = Pmax ÷ CEC-listed area 2.17 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.373 %/°C
Voc coefficient β−0.255 %/°C
Isc coefficient α+0.035 %/°C
Operating cell temperatureNOCT 45.9 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
435 W314.9 W39.85 V × 7.9 A81 W93%
440 W318.5 W40.05 V × 7.95 A81.9 W93%
445 W322 W40.15 V × 8.02 A82.8 W93%
450 W325.7 W40.25 V × 8.09 A83.8 W93%
530 W386.1 W38.33 V × 10.07 A99.5 W94%
535 W389.6 W38.47 V × 10.13 A100.4 W94%
540 W393.1 W38.61 V × 10.18 A101.3 W94%
545 W397 W38.75 V × 10.24 A102.3 W94%
550 W400.5 W38.89 V × 10.3 A103.2 W94%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
52.1 V
Voc when cold
per panel
33.1 V
Vmp when hot
per panel
11
Max panels / string
max DC 600 V
2
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet2–11
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–11
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–11
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window8–9

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V52.1 / 33.1 V✗ Not a match: module voltage below MPPT range1.39
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V52.1 / 33.1 V✓ Within range0.68
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67688811,5486.08
Palmdale1,83597312,6436.69
Chula Vista1,69689911,6856.11
Huntington Beach1,64387111,3205.89
Riverside1,69689911,6856.21
Santa Clarita1,72491411,8786.28
754Jan754Feb968Mar1,069Apr1,056May1,122Jun1,182Jul1,196Aug1,046Sep923Oct793Nov686DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 530 W panels

CEC PV Module List (Oct 7, 2026) · datasheets · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
SolarJuice American S4AI-144S-530C530 W≈20.5%−0.37349.213.76——
SEG Solar SEG-525-BTD-BG525 W≈26.9%−0.29041.116.2product 2023, 2024, 2025, 20268
JA Solar JAM72D30-530/MB530 W≈21%−0.33049.313.72product 2023, 20243
Canadian Solar CS6W-530MB-AG530 W≈20.6%−0.32448.813.8product 20241
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the SolarJuice American S4AI-144S-530C?

Calculated from the panel area (2.59 m²): about 20.5% for the 530 W class. 530 W over 2.59 m² equals about 205 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 888 kWh per year per 530 W panel in Los Angeles and about 973 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.373 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 19.3% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–11 panels per string (Voc at 2 °C = 52.1 V, Vmp at 74 °C cell = 33.1 V). Final design must follow the inverter manual and NEC 690.7.

Does it work with APsystems (Alt Power System) DS3-L microinverters?

Voltage check against the APsystems (Alt Power System) datasheet: Voc when cold 52.1 V vs max input 60 V; Vmp when hot 33.1 V vs MPPT low 28 V; recommended module power 265–570 W. Confirm on the microinverter maker’s compatibility list.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. SEG Solar — manufacturer datasheet “XXXTFHTPMBSDPN YUKON/Series )BMG$FMM/5ZQF501$PO”.
  3. Canadian Solar — datasheet BiHiKu6 BIFACIAL MONO PERC CS6W-520|525|530|535|540|545|550MB-AG.
  4. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
  5. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  6. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  7. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  8. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  9. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).