Solar panelSolarJuice American

SolarJuice American S4A-US 335

60 cells. Power classes 310–400 W in the CEC list.

CEC listed · Jun 21, 2021UL 61730
Power class
  • Power (STC)335 WCEC nameplate
  • Efficiency≈20.3%calculated from area
  • %/°C Pmax−0.396CEC listing test
  • PTC / STC91.7%PTC 307 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 12 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
S4A-US310310 W40.3010.0432.619.52≈18.8%284 WJun 21, 2021
S4A-US315315 W40.5310.1132.909.58≈19.1%288 WJun 21, 2021
S4A-US320320 W40.7810.1833.189.65≈19.4%293 WJun 21, 2021
S4A-US325325 W41.0410.2533.459.72≈19.7%298 WJun 21, 2021
S4A-US330330 W41.3010.3233.769.78≈20.0%302 WJun 21, 2021
S4A-US335335 W41.5910.3934.079.85≈20.3%307 WJun 21, 2021
S4A-US375375 W48.449.9939.749.45≈19.0%349 WJun 21, 2021
S4A-US380380 W48.7010.0640.029.51≈19.3%354 WJun 21, 2021
S4A-US385385 W48.9710.1240.289.57≈19.5%359 WJun 21, 2021
S4A-US390390 W49.2710.1740.609.62≈19.8%364 WJun 21, 2021
S4A-US395395 W49.5610.2340.899.67≈20.1%368 WJun 21, 2021
S4A-US400400 W49.8610.2941.189.73≈20.3%373 WJun 21, 2021
≈ efficiency = Pmax ÷ CEC-listed area 1.65 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.396 %/°C
Voc coefficient β−0.265 %/°C
Isc coefficient α+0.005 %/°C
Operating cell temperatureNOCT 46.8 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
310 W228.4 W29.88 V × 7.65 A60.4 W97%
315 W231.9 W30.14 V × 7.69 A61.3 W97%
320 W235.6 W30.4 V × 7.75 A62.3 W97%
325 W239.2 W30.65 V × 7.81 A63.2 W97%
330 W242.9 W30.93 V × 7.85 A64.2 W97%
335 W246.9 W31.22 V × 7.91 A65.3 W97%
375 W214.1 W28.49 V × 7.51 A73.6 W98%
380 W217 W28.69 V × 7.56 A74.6 W98%
385 W219.8 W28.88 V × 7.61 A75.6 W98%
390 W222.7 W29.11 V × 7.65 A76.6 W98%
395 W225.4 W29.32 V × 7.69 A77.5 W98%
400 W228.5 W29.53 V × 7.74 A78.6 W98%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
44.1 V
Voc when cold
per panel
27.4 V
Vmp when hot
per panel
13
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–13
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–13
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–13
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window9–11

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V44.1 / 27.4 V⚠ Works; below MPPT at peak heat1.16
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V44.1 / 27.4 V✗ Not a match: module voltage below MPPT range0.88
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V44.1 / 27.4 V⚠ Works; below MPPT at peak heat0.43
Enphase IQ8M-72-2-US260–460 W60 V30–45 V44.1 / 27.4 V⚠ Works; below MPPT at peak heat1.03
Enphase IQ8A-72-2-US295–500 W60 V32–45 V44.1 / 27.4 V⚠ Works; below MPPT at peak heat0.96
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67656111,7916.08
Palmdale1,83561512,9096.69
Chula Vista1,69656811,9316.11
Huntington Beach1,64355011,5595.89
Riverside1,69656811,9316.21
Santa Clarita1,72457812,1286.28
770Jan770Feb988Mar1,092Apr1,078May1,146Jun1,207Jul1,221Aug1,068Sep942Oct810Nov701DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 335 W panels

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · JinkoSolar datasheets · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
SolarJuice American S4A-US 335335 W≈20.3%−0.39641.5910.39——
LONGi LR4-60HPB-335M335 W≈18.5%−0.33739.910.76product 2021, 2022193
JinkoSolar JKM335M-60HBL335 W≈19.9%−0.40640.810.73brand 12× (2014–2026)45
REC Group REC340AA340 W≈20.2%−0.27943.110.09brand 9× (2016–2025)30
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the SolarJuice American S4A-US 335?

Calculated from the panel area (1.81 m²): about 20.3% for the 335 W class. 335 W over 1.81 m² equals about 185 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 561 kWh per year per 335 W panel in Los Angeles and about 615 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.396 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 20.5% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–13 panels per string (Voc at 2 °C = 44.1 V, Vmp at 74 °C cell = 27.4 V). Final design must follow the inverter manual and NEC 690.7.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. JinkoSolar — datasheet THE MOST DEPENDABLE SOLAR BRAND.
  3. JinkoSolar — manufacturer datasheet “Eagle HC 60M G2 315-335 Watt MONO PERC HALF CELL MODULE”.
  4. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
  5. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  6. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  7. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  8. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  9. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).