Cali-GrafCali-Graf
AC solar panelSolaria

Solaria Solaria PowerXT-400R-PM-AC

With a built-in IQ7A-72-2-US microinverter. Power classes 395–420 W in the CEC list.

CEC listed · Jun 1, 2020UL 1741AC module · built-in microinverter
Power class
  • Power (STC)400 WCEC nameplate
  • Efficiency≈20.2%calculated from area
  • %/°C Pmax−0.429CEC listing test
  • PTC / STC91%PTC 364 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 4 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
Solaria PowerXT-395R-PM-AC395 W50.709.7842.139.38≈19.9%359 WJun 1, 2020
Solaria PowerXT-400R-PM-AC400 W51.109.8242.409.41≈20.2%364 WJun 1, 2020
Solaria PowerXT-410R-PM-AC410 W51.709.8743.209.50≈20.7%374 WJun 1, 2020
Solaria PowerXT-420R-PM-AC420 W52.409.9443.809.60≈21.2%383 WJun 1, 2020
≈ efficiency = Pmax ÷ CEC-listed area 1.98 m².

Built-in microinverter

CEC PV Module List (Oct 7, 2026) · NLR SAM inverter library · Cali-Graf calculation
The string calculator does not apply: each panel has its own microinverter, wired as AC branch circuits.

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.429 %/°C
Voc coefficient β−0.327 %/°C
Isc coefficient α+0.052 %/°C
Operating cell temperatureNOCT 46.7 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
395 W280 W38.12 V × 7.35 A79.1 W100%
400 W282.7 W38.36 V × 7.37 A79.9 W100%
410 W290.8 W39.08 V × 7.44 A82.2 W100%
420 W297.9 W39.63 V × 7.52 A84.2 W100%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67667012,0676.08
Palmdale1,83573413,2126.69
Chula Vista1,69667812,2116.11
Huntington Beach1,64365711,8305.89
Riverside1,69667812,2116.21
Santa Clarita1,72469012,4136.28
788Jan788Feb1,012Mar1,117Apr1,104May1,173Jun1,236Jul1,250Aug1,093Sep964Oct829Nov717DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Questions & answers

How efficient is the Solaria Solaria PowerXT-400R-PM-AC?

Calculated from the panel area (1.98 m²): about 20.2% for the 400 W class. 400 W over 1.98 m² equals about 202 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 670 kWh per year per 400 W panel in Los Angeles and about 734 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.429 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 22.2% below the STC rating.

What microinverter is built into the Solaria Solaria PowerXT-400R-PM-AC?

The CEC listing names IQ7A-72-2-US paired with the Solaria PowerXT-395R-PM DC module; the microinverter is rated 290 W AC.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List (snapshot Oct 7, 2026).
  2. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  3. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  4. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  5. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).