Cali-GrafCali-Graf
Solar panelSolar4America Technology

Solar4America Technology S4A430-108TH10BB

108 half-cut cells. Power classes 425–440 W in the CEC list.

CEC listed · Jul 22, 2024UL 61730
Power class
  • Power (STC)430 WCEC nameplate
  • Efficiency≈22.8%calculated from area
  • %/°C Pmax−0.293CEC listing test
  • PTC / STC95.1%PTC 409 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 4 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
S4A425-108TH10BB425 W37.8714.1931.6613.42≈22.5%404 WJul 22, 2024
S4A430-108TH10BB430 W37.9614.3131.9713.45≈22.8%409 WJul 22, 2024
S4A435-108TH10BB435 W38.2514.4432.2713.48≈23.0%414 WJul 22, 2024
S4A440-108TH10BB440 W38.5714.4932.4113.58≈23.3%419 WJul 22, 2024
≈ efficiency = Pmax ÷ CEC-listed area 1.89 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.293 %/°C
Voc coefficient β−0.230 %/°C
Isc coefficient α+0.042 %/°C
Operating cell temperatureNOCT 43.1 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
425 W320.5 W31.41 V × 10.2 A80.7 W95%
430 W324.3 W31.72 V × 10.22 A81.7 W95%
435 W328.1 W32.02 V × 10.25 A82.7 W95%
440 W332 W32.16 V × 10.32 A83.6 W95%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
40 V
Voc when cold
per panel
26.7 V
Vmp when hot
per panel
15
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–15
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–15
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–15
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window9–12

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V40 / 26.7 V⚠ Works; below MPPT at peak heat1.48
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V40 / 26.7 V✗ Not a match: module voltage below MPPT range1.13
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V40 / 26.7 V⚠ Works; below MPPT at peak heat0.55
Enphase IQ8M-72-2-US260–460 W60 V30–45 V40 / 26.7 V⚠ Works; below MPPT at peak heat1.32
Enphase IQ8A-72-2-US295–500 W60 V32–45 V40 / 26.7 V✗ Not a match: module voltage below MPPT range1.23
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67672111,5316.08
Palmdale1,83578912,6256.69
Chula Vista1,69672911,6686.11
Huntington Beach1,64370611,3045.89
Riverside1,69672911,6686.21
Santa Clarita1,72474111,8616.28
753Jan753Feb967Mar1,068Apr1,055May1,121Jun1,181Jul1,194Aug1,044Sep921Oct792Nov685DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 430 W panels

CEC PV Module List (Oct 7, 2026) · datasheets · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, AWarrantyPVEL (product / brand)SoCal permits (series)
Solar4America Technology S4A430-108TH10BB430 W≈22.8%−0.29337.9614.31———
Canadian Solar CS3N-430MS430 W≈21.8%−0.33245.711.8625 yrproduct 202346
Qcells Q.TRON BLK M-G2+ 430430 W≥22%−0.27639.3213.7425 / 25 yrbrand 11× (2016–2026)40
Silfab Solar SIL-430QD430 W≈22.1%−0.29438.9113.8725 / 30 yrbrand 7× (2017–2025)39
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the Solar4America Technology S4A430-108TH10BB?

Calculated from the panel area (1.89 m²): about 22.8% for the 430 W class. 430 W over 1.89 m² equals about 228 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 721 kWh per year per 430 W panel in Los Angeles and about 789 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.293 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 15.2% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–15 panels per string (Voc at 2 °C = 40 V, Vmp at 74 °C cell = 26.7 V). Final design must follow the inverter manual and NEC 690.7.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Canadian Solar — manufacturer datasheet “HiKu Mono PERC CS3N-400|405|410|415|420|425MS MORE POWER”.
  3. Qcells — manufacturer datasheet “Q.TRON BLK M-G2+ SERIES 415–440 Wp”.
  4. Silfab Solar — datasheet NTC SIL-420 QD CELL TECHNOLOGY.
  5. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
  6. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  7. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  8. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  9. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  10. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).