Solar panelSKYCELL USA

SKYCELL USA SKY 700-BHDG24-USA

132 half-cut cells, bifacial. Power classes 680–725 W in the CEC list.

CEC listed · Jul 22, 2024UL 61730Bifacial
Power class
  • Power (STC)700 WCEC nameplate
  • Efficiency≈22.5%calculated from area
  • %/°C Pmax−0.249CEC listing test
  • PTC / STC95.3%PTC 667 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 10 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
SKY 680-BHDG24-USA680 W48.9116.9842.4416.05≈21.9%648 WJul 22, 2024
SKY 685-BHDG24-USA685 W48.9717.0642.6316.09≈22.0%652 WJul 22, 2024
SKY 690-BHDG24-USA690 W49.0417.1442.8216.14≈22.2%657 WJul 22, 2024
SKY 695-BHDG24-USA695 W49.1017.2243.0216.18≈22.3%662 WJul 22, 2024
SKY 700-BHDG24-USA700 W49.1717.3143.2116.23≈22.5%667 WJul 22, 2024
SKY 705-BHDG24-USA705 W49.2417.3943.4016.27≈22.7%672 WJul 22, 2024
SKY 710-BHDG24-USA710 W49.3017.4743.5316.34≈22.8%677 WJul 22, 2024
SKY 715-BHDG24-USA715 W50.5917.6142.5416.81≈23.0%682 WJul 22, 2024
SKY 720-BHDG24-USA720 W50.7417.6742.6816.87≈23.2%686 WJul 22, 2024
SKY 725-BHDG24-USA725 W50.8817.7342.8316.93≈23.3%691 WJul 22, 2024
≈ efficiency = Pmax ÷ CEC-listed area 3.11 m².

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.249 %/°C
Voc coefficient β−0.232 %/°C
Isc coefficient α+0.043 %/°C
Operating cell temperatureNOCT 45.6 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
680 W516.2 W39.33 V × 13.12 A133 W98%
685 W519.8 W39.51 V × 13.16 A133.9 W98%
690 W523.7 W39.69 V × 13.2 A135 W98%
695 W527.5 W39.87 V × 13.23 A135.9 W98%
700 W531.5 W40.05 V × 13.27 A136.9 W98%
705 W535.1 W40.22 V × 13.3 A137.9 W98%
710 W539 W40.35 V × 13.36 A138.9 W98%
715 W541.9 W39.43 V × 13.74 A139.6 W98%
720 W545.6 W39.56 V × 13.79 A140.6 W98%
725 W549.5 W39.7 V × 13.84 A141.6 W98%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
51.8 V
Voc when cold
per panel
37 V
Vmp when hot
per panel
11
Max panels / string
max DC 600 V
2
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet2–11
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–11
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet3–11
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window7–9

Microinverters (one per panel)

No microinverter in the reference set lists this power class in its recommended module power range.
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,6761,17311,7326.08
Palmdale1,8351,28412,8456.69
Chula Vista1,6961,18711,8726.11
Huntington Beach1,6431,15011,5015.89
Riverside1,6961,18711,8726.21
Santa Clarita1,7241,20712,0686.28
766Jan766Feb984Mar1,086Apr1,073May1,140Jun1,201Jul1,215Aug1,063Sep937Oct806Nov697DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 700 W panels

CEC PV Module List (Oct 7, 2026) · datasheets · Kiwa PVEL Scorecard
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)
SKYCELL USA SKY 700-BHDG24-USA700 W≈22.5%−0.24949.1717.31—
Canadian Solar CS7N-700TB-AG700 W≈22.5%−0.28547.918.49product 2024
Phono Solar PS700M13GFH-22/WNH700 W≈22.7%−0.29148.618.1brand 9× (2016–2026)
Waaree BiN-03-700700 W≥22.5%−0.30248.1518.32brand 5× (2022–2026)
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the SKYCELL USA SKY 700-BHDG24-USA?

Calculated from the panel area (3.11 m²): about 22.5% for the 700 W class. 700 W over 3.11 m² equals about 225 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 1,173 kWh per year per 700 W panel in Los Angeles and about 1,284 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.249 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 12.9% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–11 panels per string (Voc at 2 °C = 51.8 V, Vmp at 74 °C cell = 37 V). Final design must follow the inverter manual and NEC 690.7.

Is it bifacial?

Yes. Rear gain depends on mounting height and ground reflectance.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Canadian Solar — datasheet New N-type Bifacial Module TOPBiHiKu7 CS7N-725|730|735|740|745|750TB-AG.
  3. Waaree — datasheet ELITE SERIES BiN-03.
  4. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
  5. NLR (formerly NREL) — System Advisor Model CEC module and inverter libraries (version 2026.7.3).
  6. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  7. Inverter datasheets — Solis (Ginlong), Tesla (manufacturer documents).
  8. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).