CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ
−0.375 %/°C
Voc coefficient β
−0.246 %/°C
Isc coefficient α
+0.006 %/°C
Operating cell temperature
NOCT 48.2 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.
Away from lab conditions — CEC listing test points
Class
Pmax at NOCT
Vmp × Imp at NOCT
Pmax at 200 W/m²
Low-light efficiency vs STC
310 W
226.4 W
30.1 V × 7.52 A
61.6 W
99%
315 W
229.1 W
30.3 V × 7.56 A
62.8 W
100%
320 W
233.2 W
30.6 V × 7.62 A
63.6 W
99%
325 W
236.5 W
30.8 V × 7.68 A
64.5 W
99%
330 W
240.1 W
31.1 V × 7.72 A
65.8 W
100%
335 W
244.3 W
31.4 V × 7.78 A
66.7 W
100%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).
Inverter compatibility & string sizing
CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
44 V
Voc when cold
per panel
27.7 V
Vmp when hot
per panel
13
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.
String inverters most named in SoCal permits
Inverter
Max DC input
MPPT
Window source
Panels per string
Tesla 1538000-xx-y
600 V
60–480 V
datasheet
3–13
Solis (Ginlong) S6-EH1P10K-H-US
600 V
80–520 V
datasheet
3–13
Solis (Ginlong) Solis-1P7.6K-4G-US
600 V
100–500 V
datasheet
4–13
Qcells Q.VOLT H7.6SX
498 V
234–498 V
CEC test window
9–11
Microinverters (one per panel)
Microinverter
Recommended module power
Max DC input
MPPT
Voc cold / Vmp hot
Check
DC/AC
Enphase IQ8PLUS-72-2-US
235–440 W
60 V
29–45 V
44 / 27.7 V
⚠ Works; below MPPT at peak heat
1.16
Enphase IQ8X-80-M-US
320–540 W
79.5 V
43–60 V
44 / 27.7 V
✗ Not a match: module voltage below MPPT range
0.88
APsystems (Alt Power System) DS3-L
265–570 W
60 V
28–45 V
44 / 27.7 V
⚠ Works; below MPPT at peak heat
0.43
Enphase IQ8M-72-2-US
260–460 W
60 V
30–45 V
44 / 27.7 V
⚠ Works; below MPPT at peak heat
1.03
Enphase IQ8A-72-2-US
295–500 W
60 V
32–45 V
44 / 27.7 V
⚠ Works; below MPPT at peak heat
0.96
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.
Expected production in Southern California
NLR PVWatts v8 · Cali-Graf calculation
City
kWh / kW / yr
kWh / panel / yr
kWh / system / yr
Sun, kWh/m²/day
Los Angeles
1,676
561
11,791
6.08
Palmdale
1,835
615
12,909
6.69
Chula Vista
1,696
568
11,931
6.11
Huntington Beach
1,643
550
11,559
5.89
Riverside
1,696
568
11,931
6.21
Santa Clarita
1,724
578
12,128
6.28
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.
Who installs STS-xxxM3B-60 panels in SoCal
building permits
3
Permits naming this series
Aug 2024 – Oct 2024
1
Jurisdictions so far
LA County (unincorp.) (3)
Only installer and ZIP level is shown — no homeowner names, street addresses or permit numbers. Permits from LA County (unincorp.) come without a contractor license, so they count toward totals but not toward installers. Counts grow as more permit portals are loaded.
Installed together with
building permits
Microinverters
Enphase IQ8+
2
Number of permits naming both this panel series and the product; 3 of 3 permits list other equipment.
Compare with similar 335 W panels
CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · JinkoSolar datasheets · building permits
Panel
Pmax
Efficiency
γ Pmax (CEC)
Voc, V
Isc, A
PVEL (product / brand)
SoCal permits (series)
Sinotec USA STS-335M3B-60
335 W
≈20.3%
−0.375
41.6
10.39
—
3
LONGi LR4-60HPB-335M
335 W
≈18.5%
−0.337
39.9
10.76
product 2021, 2022
193
JinkoSolar JKM335M-60HBL
335 W
≈19.9%
−0.406
40.8
10.73
brand 12× (2014–2026)
45
REC Group REC340AA
340 W
≈20.2%
−0.279
43.1
10.09
brand 9× (2016–2025)
30
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.
Questions & answers
How efficient is the Sinotec USA STS-335M3B-60?
Calculated from the panel area (1.65 m²): about 20.3% for the 335 W class. 335 W over 1.65 m² equals about 203 W per square meter.
How much energy does one panel produce in Los Angeles or Palmdale?
PVWatts v8 with typical-year weather gives about 561 kWh per year per 335 W panel in Los Angeles and about 615 kWh in Palmdale (20° roof, facing south, 14% system losses).
How much power does it lose on a hot roof?
With γ = −0.375 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 19.4% below the STC rating.
How many panels fit on one string?
With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–13 panels per string (Voc at 2 °C = 44 V, Vmp at 74 °C cell = 27.7 V). Final design must follow the inverter manual and NEC 690.7.
Sources
California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
JinkoSolar — manufacturer datasheet “Eagle HC 60M G2 315-335 Watt MONO PERC HALF CELL MODULE”.
Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
Building permits — Los Angeles County Public Works (EPIC-LA, unincorporated areas) (Aug 2024 – Oct 2024). Equipment matched from permit descriptions by model number.
Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).
Get your free estimate
Three fields, and Cali Energy calls back within 30 minutes during business hours.
Thanks!
We got your request and will call back within 30 minutes during business hours.