This exact series is not listed in published PVEL Top Performer tables. Results below are for the manufacturer.
RETC PV Module Index — Silfab Solar
Year
Recognition
2023
High Achievement in Performance (Ptc-to-stc ratio, LeTID RESISTANCE, Module efficiency)
2024
High Achievement in Performance
2025
Performance High Achiever
2026
Performance discipline high achiever (Lid); Quality discipline high achiever (BOM verification); Reliability discipline high achiever (Pid, Sdml); Test Category High Achiever
Inverter compatibility & string sizing
Silfab Solar datasheet · Cali-Graf calculation · NLR PVWatts v8 · CEC PV Module List (Oct 7, 2026) · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
42.7 V
Voc when cold
per panel
26.7 V
Vmp when hot
per panel
14
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above.
String inverters most named in SoCal permits
Inverter
Max DC input
MPPT
Window source
Panels per string
Tesla 1538000-xx-y
600 V
60–480 V
datasheet
3–14
Solis (Ginlong) S6-EH1P10K-H-US
600 V
80–520 V
datasheet
3–14
Solis (Ginlong) Solis-1P7.6K-4G-US
600 V
100–500 V
datasheet
4–14
Qcells Q.VOLT H7.6SX
498 V
234–498 V
CEC test window
9–11
Microinverters (one per panel)
Microinverter
Recommended module power
Max DC input
MPPT
Voc cold / Vmp hot
Check
DC/AC
Enphase IQ8PLUS-72-2-US
235–440 W
60 V
29–45 V
42.7 / 26.7 V
⚠ Works; below MPPT at peak heat
1.14
Enphase IQ8X-80-M-US
320–540 W
79.5 V
43–60 V
42.7 / 26.7 V
✗ Not a match: module voltage below MPPT range
0.87
APsystems (Alt Power System) DS3-L
265–570 W
60 V
28–45 V
42.7 / 26.7 V
⚠ Works; below MPPT at peak heat
0.42
Enphase IQ8M-72-2-US
260–460 W
60 V
30–45 V
42.7 / 26.7 V
⚠ Works; below MPPT at peak heat
1.02
Enphase IQ8A-72-2-US
295–500 W
60 V
32–45 V
42.7 / 26.7 V
⚠ Works; below MPPT at peak heat
0.95
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.
Expected production in Southern California
NLR PVWatts v8 · Cali-Graf calculation
City
kWh / kW / yr
kWh / panel / yr
kWh / system / yr
Sun, kWh/m²/day
Los Angeles
1,676
553
11,615
6.08
Palmdale
1,835
606
12,717
6.69
Chula Vista
1,696
560
11,753
6.11
Huntington Beach
1,643
542
11,386
5.89
Riverside
1,696
560
11,753
6.21
Santa Clarita
1,724
569
11,947
6.28
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.
Compare with similar 330 W panels
CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · datasheets · building permits
Panel
Pmax
Efficiency
γ Pmax (CEC)
Voc, V
Isc, A
Size
Warranty
PVEL (product / brand)
SoCal permits (series)
Silfab Solar SIL-330HL
330 W
≥19.4%
−0.325
40.1
10.4
66.9 × 39.4 in
25 / 30 yr
brand 7×
1
LONGi LR4-60HPB-335M
335 W
≈18.5%
−0.337
39.9
10.76
—
—
product 2021, 2022
193
JinkoSolar JKM330M-60HBL
330 W
≈19.6%
−0.406
40.6
10.61
66.3 × 39.4 in
10 / 25 yr
brand 12× (2014–2026)
45
Qcells Q.PEAK DUO-G8+ 330
330 W
≈18.4%
−0.343
39.71
10.52
68.5 × 40.6 in
25 / 25 yr
product 2022
20
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.
The Silfab Solar datasheet guarantees at least 19.4% module efficiency for the 330 W class. 330 W over 1.7 m² equals about 194 W per square meter.
How much energy does one panel produce in Los Angeles or Palmdale?
PVWatts v8 with typical-year weather gives about 553 kWh per year per 330 W panel in Los Angeles and about 606 kWh in Palmdale (20° roof, facing south, 14% system losses).
How much power does it lose on a hot roof?
With γ = −0.36 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 18.6% below the STC rating.
How many panels fit on one string?
With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–14 panels per string (Voc at 2 °C = 42.7 V, Vmp at 74 °C cell = 26.7 V). Final design must follow the inverter manual and NEC 690.7.
What does the warranty cover?
25 years on the product and 30 years on performance: at least 82.6% after 30 years (manufacturer datasheet).
NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
Building permits — Los Angeles County Public Works (EPIC-LA, unincorporated areas) (Jul 2021). Equipment matched from permit descriptions by model number.
Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).
Get your free estimate
Three fields, and Cali Energy calls back within 30 minutes during business hours.
Thanks!
We got your request and will call back within 30 minutes during business hours.