Silfab Solar SIL-370HC

120 half-cut cells, PERC. Power classes 360–385 W in the CEC list.

CEC listed · May 3, 2021UL 6173025-yr product + 30-yr performance warrantyPVEL Top Performer 2023PERCInstalled in 9 SoCal permits
Power class
  • Power (STC)370 WCEC nameplate
  • Efficiency≈20.2%calculated from area
  • %/°C Pmax−0.36CEC test: −0.379
  • Output at year 3082.6%performance warranty

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 6 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
SIL-360HC360 W41.3411.1434.5910.41≈19.7%330 WMay 3, 2021
SIL-365HC365 W41.5411.2034.7610.51≈20.0%335 WMay 3, 2021
SIL-370HC370 W41.7511.2534.9510.60≈20.2%340 WMay 3, 2021
SIL-375HC375 W41.9611.3035.1410.68≈20.5%345 WMay 3, 2021
SIL-380HC380 W42.1711.3635.3210.77≈20.8%349 WMay 3, 2021
SIL-385HC385 W42.3811.4135.5010.86≈21.1%354 WMay 3, 2021
≈ efficiency = Pmax ÷ panel area 1.827 m² (datasheet size).

Build & dimensions

Silfab Solar datasheet · Cali-Graf calculation · CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

Silfab Solar datasheet · CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
DatasheetCEC listing test
Pmax coefficient γ−0.36 %/°C−0.379 %/°C
Voc coefficient β−0.28 %/°C−0.279 %/°C
Isc coefficient α+0.06 %/°C+0.018 %/°C
Vmp coefficient≈ −0.42 %/°C—
Operating cell temperatureNMOT 45 °CNOCT 47.6 °C
Vmp coefficient ≈ γ − α (datasheet); used only for the hot-roof voltage estimate.

At normal operating conditions (NOCT, 800 W/m²) — datasheet

ClassPmax, WVoc, VIsc, AVmp, VImp, A
370 W276.039.169.0732.488.50

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
360 W256.4 W30.64 V × 8.37 A70 W97%
365 W260.1 W30.79 V × 8.45 A71 W97%
370 W263.8 W30.96 V × 8.52 A72 W97%
375 W267.2 W31.13 V × 8.58 A72.9 W97%
380 W270.8 W31.29 V × 8.66 A73.9 W97%
385 W274.5 W31.45 V × 8.73 A74.9 W97%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Electrical & strength ratings

Silfab Solar datasheet
Packaging: 26 per pallet

Certifications

CEC PV Module List (Oct 7, 2026) · Silfab Solar datasheet
UL 61730UL 1703IEC 61215IEC 61701IEC 62716IEC 62790ISO 9001

Warranty & degradation

Silfab Solar datasheet

Independent reliability testing

Kiwa PVEL Scorecard · RETC PV Module Index
2023
PVEL Top Performer
this series
3
Tests passed as Top Performer
LID+LETID, MSS, PID
7
PVEL Scorecards
Silfab Solar named Top Performer, 2017–2025
4
RETC PV Module Index
Silfab Solar recognized 2023–2026

PVEL Top Performer tests

YearProductTests
2023SIL-xxxHC+LID+LETIDMSSPID
2023SIL-xxxHCLID+LETIDMSSPID

Tested bill of materials

Details describe the tested sample, not every module of the series.

RETC PV Module Index — Silfab Solar

YearRecognition
2023High Achievement in Performance (Ptc-to-stc ratio, LeTID RESISTANCE, Module efficiency)
2024High Achievement in Performance
2025Performance High Achiever
2026Performance discipline high achiever (Lid); Quality discipline high achiever (BOM verification); Reliability discipline high achiever (Pid, Sdml); Test Category High Achiever

Inverter compatibility & string sizing

Silfab Solar datasheet · Cali-Graf calculation · NLR PVWatts v8 · CEC PV Module List (Oct 7, 2026) · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
44.4 V
Voc when cold
per panel
27.7 V
Vmp when hot
per panel
13
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–13
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–13
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–13
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window9–11

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V44.4 / 27.7 V⚠ Works; below MPPT at peak heat1.28
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V44.4 / 27.7 V✗ Not a match: module voltage below MPPT range0.97
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V44.4 / 27.7 V⚠ Works; below MPPT at peak heat0.47
Enphase IQ8M-72-2-US260–460 W60 V30–45 V44.4 / 27.7 V⚠ Works; below MPPT at peak heat1.14
Enphase IQ8A-72-2-US295–500 W60 V32–45 V44.4 / 27.7 V⚠ Works; below MPPT at peak heat1.06
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67662011,7826.08
Palmdale1,83567912,9006.69
Chula Vista1,69662811,9236.11
Huntington Beach1,64360811,5505.89
Riverside1,69662811,9236.21
Santa Clarita1,72463812,1206.28
769Jan770Feb988Mar1,091Apr1,078May1,145Jun1,206Jul1,220Aug1,067Sep941Oct809Nov700DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Who installs SIL-xxxHC panels in SoCal

building permits
9
Permits naming this series
Mar 2022 – Apr 2025
2
Jurisdictions so far
LA County (unincorp.) (8), Palmdale (1)

Permits over time

1Q1 ’220Q2 ’223Q3 ’220Q4 ’220Q1 ’231Q2 ’230Q3 ’230Q4 ’232Q1 ’240Q2 ’241Q3 ’240Q4 ’240Q1 ’251Q2 ’25permits per quarter

Power class named in permit

370 W
8
380 W
1

Typical system

median 10.4 kW, 24 panels (n = 5)

Only installer and ZIP level is shown — no homeowner names, street addresses or permit numbers. Permits from LA County (unincorp.) come without a contractor license, so they count toward totals but not toward installers. Counts grow as more permit portals are loaded.

Installed together with

building permits

Microinverters

Enphase IQ8+
3
Enphase IQ7+
2

Inverters

SolarEdge SE…H (HD-Wave)
2

Optimizers

SolarEdge Power Optimizer
2

Batteries

Enphase IQ Battery 5P
2
Number of permits naming both this panel series and the product; 9 of 9 permits list other equipment.

Compare with similar 370 W panels

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · Canadian Solar datasheet · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
Silfab Solar SIL-370HC370 W≈20.2%−0.37941.7511.25product 20239
LONGi LR4-60HPB-370M370 W≈20.9%−0.33941.211.5product 2021, 2022193
Canadian Solar CS3N-375MS {Blk}375 W≈19%−0.34243.511.2product 202346
REC Group REC370AA370 W≈21.9%−0.25844.110.55brand 9× (2016–2025)30
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Documents

manufacturer documents

About Silfab Solar

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · RETC PV Module Index · building permits

Other series by SoCal permits

SIL-xxxQD · 39SIL-xxxHC+ · 28SIL-xxxBK · 10SIL-xxxNX · 6SIL-xxxBG · 5SIL-xxxNL · 2

Questions & answers

How efficient is the Silfab Solar SIL-370HC?

Calculated from the panel area (1.83 m²): about 20.2% for the 370 W class. 370 W over 1.83 m² equals about 203 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 620 kWh per year per 370 W panel in Los Angeles and about 679 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.36 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 18.6% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–13 panels per string (Voc at 2 °C = 44.4 V, Vmp at 74 °C cell = 27.7 V). Final design must follow the inverter manual and NEC 690.7.

What does the warranty cover?

25 years on the product and 30 years on performance: at least 82.6% after 30 years (manufacturer datasheet).

How big and heavy is it?

69.4 × 40.8 × 1.38 in (1,762 × 1,037 × 35 mm), 43 lb (19.5 kg).

Has this panel been reliability-tested?

SIL-xxxHC+ was a PVEL Top Performer in 2023 (LID+LETID, MSS, PID).

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Silfab Solar — datasheet SIL-370 HC DIRECT FROM THE SOURCE. Designed to outperform..
  3. Canadian Solar — manufacturer datasheet “HiKu Mono PERC CS3N-400|405|410|415|420|425MS MORE POWER”.
  4. Silfab Solar — document library on the manufacturer’s website (links above).
  5. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2017–2025.
  6. RETC — PV Module Index reports 2023–2026.
  7. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  8. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  9. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  10. Building permits — Los Angeles County Public Works (EPIC-LA, unincorporated areas) (Mar 2022 – Apr 2025); City of Palmdale (Feb 2024). Equipment matched from permit descriptions by model number.
  11. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).