Cali-GrafCali-Graf
Solar panelSilfab Solar

Silfab Solar SIL-330BL

126 half-cut cells, PERC. Power classes 290–345 W in the CEC list; datasheet covers 320–320 W.

CEC listed · Sep 3, 2019UL 6173025-yr product + 30-yr performance warrantyPVEL Top Performer 2021PERCInstalled in 1 SoCal permit
Power class
  • Power (STC)330 WCEC nameplate
  • Efficiency≈19.4%calculated from area
  • %/°C Pmax−0.38CEC test: −0.369
  • Output at year 3082.6%performance warranty

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · Silfab Solar datasheet · 12 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
SIL290BL290 W37.629.7232.528.90≈17.1%259 WSep 3, 2019
SIL295BL295 W38.159.7632.758.99≈17.4%263 WSep 3, 2019
SIL300BL300 W38.699.8132.999.08≈17.6%268 WSep 3, 2019
SIL305BL305 W41.749.6933.819.04≈17.9%284 WSep 3, 2019
SIL-310BL310 W41.849.7234.009.13≈18.2%290 WSep 3, 2019
SIL-315BL315 W41.949.7534.189.23≈18.5%295 WSep 3, 2019
SIL-320BL320 W42.049.7834.369.32≥18.8%300 WSep 3, 2019
SIL-325BL325 W42.139.8134.539.42≈19.1%304 WSep 3, 2019
SIL-330BL330 W42.239.8434.729.52≈19.4%309 WSep 3, 2019
SIL-335BL335 W42.329.8734.899.61≈19.7%314 WJan 13, 2020
SIL-340BL340 W42.429.9035.089.71≈20.0%319 WJul 21, 2020
SIL-345BL345 W42.529.9335.269.80≈20.3%324 WJul 21, 2020
≈ efficiency = Pmax ÷ panel area 1.7 m² (datasheet size) for classes outside the datasheet.

Build & dimensions

Silfab Solar datasheet · Cali-Graf calculation · CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

Silfab Solar datasheet · CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
DatasheetCEC listing test
Pmax coefficient γ−0.38 %/°C−0.369 %/°C
Voc coefficient β−0.28 %/°C−0.266 %/°C
Isc coefficient α+0.05 %/°C+0.018 %/°C
Vmp coefficient≈ −0.42 %/°C—
Operating cell temperatureNMOT 43.5 °CNOCT 42.7 °C
Vmp coefficient ≈ γ − α (datasheet); used only for the hot-roof voltage estimate.

At normal operating conditions (NOCT, 800 W/m²) — datasheet

ClassPmax, WVoc, VIsc, AVmp, VImp, A
320 W239.439.507.8832.187.44

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
290 W192.6 W27.7 V × 6.95 A53.1 W92%
295 W195.8 W27.9 V × 7.02 A54 W92%
300 W199.2 W28.1 V × 7.09 A54.9 W92%
305 W225.6 W31.32 V × 7.2 A58.6 W96%
310 W220.2 W31.17 V × 7.06 A59.4 W96%
315 W223.7 W31.34 V × 7.14 A60.3 W96%
320 W227.2 W31.5 V × 7.21 A61.3 W96%
325 W230.7 W31.66 V × 7.29 A62.2 W96%
330 W234.3 W31.83 V × 7.36 A63.2 W96%
335 W237.8 W32 V × 7.43 A64.2 W96%
340 W241.4 W32.16 V × 7.51 A65.1 W96%
345 W245 W32.33 V × 7.58 A66.1 W96%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Electrical & strength ratings

Silfab Solar datasheet
Packaging: 26 per pallet

Certifications

CEC PV Module List (Oct 7, 2026) · Silfab Solar datasheet
UL 61730UL 1703IEC 61215IEC 61730IEC 62804ISO 9001

Warranty & degradation

Silfab Solar datasheet

Independent reliability testing

Kiwa PVEL Scorecard · RETC PV Module Index
2021
PVEL Top Performer
this series
3
Tests passed as Top Performer
DH, PID, TC
7
PVEL Scorecards
Silfab Solar named Top Performer, 2017–2025
4
RETC PV Module Index
Silfab Solar recognized 2023–2026

PVEL Top Performer tests

YearProductTests
2021SIL-xxxBLDHPIDTC

RETC PV Module Index — Silfab Solar

YearRecognition
2023High Achievement in Performance (Ptc-to-stc ratio, LeTID RESISTANCE, Module efficiency)
2024High Achievement in Performance
2025Performance High Achiever
2026Performance discipline high achiever (Lid); Quality discipline high achiever (BOM verification); Reliability discipline high achiever (Pid, Sdml); Test Category High Achiever

Inverter compatibility & string sizing

Silfab Solar datasheet · Cali-Graf calculation · NLR PVWatts v8 · CEC PV Module List (Oct 7, 2026) · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
44.9 V
Voc when cold
per panel
27.5 V
Vmp when hot
per panel
13
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–13
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–13
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–13
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window9–11

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V44.9 / 27.5 V⚠ Works; below MPPT at peak heat1.14
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V44.9 / 27.5 V✗ Not a match: module voltage below MPPT range0.87
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V44.9 / 27.5 V⚠ Works; below MPPT at peak heat0.42
Enphase IQ8M-72-2-US260–460 W60 V30–45 V44.9 / 27.5 V⚠ Works; below MPPT at peak heat1.02
Enphase IQ8A-72-2-US295–500 W60 V32–45 V44.9 / 27.5 V⚠ Works; below MPPT at peak heat0.95
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67655311,6156.08
Palmdale1,83560612,7176.69
Chula Vista1,69656011,7536.11
Huntington Beach1,64354211,3865.89
Riverside1,69656011,7536.21
Santa Clarita1,72456911,9476.28
758Jan759Feb974Mar1,076Apr1,062May1,129Jun1,189Jul1,203Aug1,052Sep928Oct798Nov690DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Who installs SIL-xxxBL panels in SoCal

building permits · CSLB License Master
1
Permits naming this series
Jun 2021
1
Licensed installers
CSLB license on the permit
1
Jurisdictions so far
Los Angeles (1)
Only installer and ZIP level is shown — no homeowner names, street addresses or permit numbers. Counts grow as more permit portals are loaded.

Compare with similar 330 W panels

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · datasheets · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, ASizeWarrantyPVEL (product / brand)SoCal permits (series)
Silfab Solar SIL-330BL330 W≈19.4%−0.36942.239.8466.9 × 39.4 in25 / 30 yrproduct 20211
LONGi LR4-60HPB-335M335 W≈18.5%−0.33739.910.76——product 2021, 2022193
JinkoSolar JKM330M-60HBL330 W≈19.6%−0.40640.610.6166.3 × 39.4 in10 / 25 yrbrand 12× (2014–2026)45
Qcells Q.PEAK DUO-G8+ 330330 W≈18.4%−0.34339.7110.5268.5 × 40.6 in25 / 25 yrproduct 202220
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Documents

manufacturer documents

About Silfab Solar

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · RETC PV Module Index · building permits

Other series by SoCal permits

SIL-xxxQD · 39SIL-xxxHC+ · 28SIL-xxxBK · 10SIL-xxxHC · 9SIL-xxxNX · 6SIL-xxxBG · 5

Questions & answers

How efficient is the Silfab Solar SIL-330BL?

Calculated from the panel area (1.7 m²): about 19.4% for the 330 W class. 330 W over 1.7 m² equals about 194 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 553 kWh per year per 330 W panel in Los Angeles and about 606 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.38 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 19.5% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–13 panels per string (Voc at 2 °C = 44.9 V, Vmp at 74 °C cell = 27.5 V). Final design must follow the inverter manual and NEC 690.7.

What does the warranty cover?

25 years on the product and 30 years on performance: at least 82.6% after 30 years (manufacturer datasheet).

How big and heavy is it?

66.9 × 39.4 × 1.5 in (1,700 × 1,000 × 38 mm), 40.1 lb (18.2 kg).

Has this panel been reliability-tested?

SIL-xxxBL was a PVEL Top Performer in 2021 (DH, PID, TC).

Who installs it in Southern California?

Building permits name this series 1 times (Jun 2021). The most active licensed installers are Semper Solaris.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Silfab Solar — datasheet BC Series SIL-320 BL BAA JUST.
  3. JinkoSolar — datasheet THE MOST DEPENDABLE SOLAR BRAND.
  4. JinkoSolar — manufacturer datasheet “Eagle HC 60M G2 315-335 Watt MONO PERC HALF CELL MODULE”.
  5. Qcells — manufacturer datasheet “Q.PEAK DUO-G8+ 345-360 EN ENDURING HIGH”.
  6. Silfab Solar — document library on the manufacturer’s website (links above).
  7. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2017–2025.
  8. RETC — PV Module Index reports 2023–2026.
  9. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  10. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  11. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  12. Building permits — LADBS, City of Los Angeles (Jun 2021). Equipment matched from permit descriptions by model number.
  13. Contractors State License Board — License Master (contractor names and license status), as of Oct 5, 2026.
  14. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).