Cali-GrafCali-Graf
Solar panelShinsung E&G

Shinsung E&G SSV430-144MH-BW

144 half-cut cells. Power classes 375–470 W in the CEC list.

CEC listed · Nov 1, 2021UL 61730
Power class
  • Power (STC)430 WCEC nameplate
  • Efficiency≈19.6%calculated from area
  • %/°C Pmax−0.373CEC listing test
  • PTC / STC92.8%PTC 399 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 16 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
SSV375-144MH-BW375 W47.8010.0039.609.47≈18.8%347 WNov 1, 2021
SSV380-144MH-BW380 W48.1010.0639.909.53≈19.1%352 WNov 1, 2021
SSV385-144MH-BW385 W48.4010.1240.209.59≈19.3%356 WNov 1, 2021
SSV390-144MH-BW390 W48.5010.2240.309.68≈19.6%361 WNov 1, 2021
SSV395-144MH-BW395 W48.7010.3140.509.76≈19.8%366 WNov 1, 2021
SSV400-144MH-BW400 W48.9010.3940.709.83≈20.1%371 WNov 1, 2021
SSV405-144MH-BW405 W49.1010.4840.909.91≈20.4%376 WNov 1, 2021
SSV430-144MH-BW430 W49.2011.1940.6010.60≈19.6%399 WNov 1, 2021
SSV435-144MH-BW435 W49.4011.2640.8010.67≈19.9%404 WNov 1, 2021
SSV440-144MH-BW440 W49.6011.3441.0010.74≈20.1%408 WNov 1, 2021
SSV445-144MH-BW445 W49.8011.4241.2010.81≈20.3%413 WNov 1, 2021
SSV450-144MH-BW450 W50.0011.5041.4010.87≈20.5%418 WNov 1, 2021
SSV455-144MH-BW455 W50.2011.5941.6010.94≈20.8%423 WNov 1, 2021
SSV460-144MH-BW460 W50.4011.6741.8011.01≈21.0%428 WNov 1, 2021
SSV465-144MH-BW465 W50.6011.7442.0011.08≈21.2%432 WNov 1, 2021
SSV470-144MH-BW470 W50.8011.8142.2011.14≈21.5%437 WNov 1, 2021
≈ efficiency = Pmax ÷ CEC-listed area 1.99 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.373 %/°C
Voc coefficient β−0.298 %/°C
Isc coefficient α+0.047 %/°C
Operating cell temperatureNOCT 45 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
375 W278.6 W37.18 V × 7.49 A71.4 W95%
380 W282.5 W37.46 V × 7.54 A72.4 W95%
385 W286.4 W37.75 V × 7.59 A73.4 W95%
390 W289.9 W37.84 V × 7.66 A74.3 W95%
395 W293.7 W38.03 V × 7.72 A75.3 W95%
400 W297.3 W38.22 V × 7.78 A76.2 W95%
405 W301.2 W38.4 V × 7.84 A77.2 W95%
430 W322 W37.95 V × 8.48 A84.8 W99%
435 W325.7 W38.14 V × 8.54 A85.8 W99%
440 W329.4 W38.33 V × 8.6 A86.8 W99%
445 W333.2 W38.51 V × 8.65 A87.7 W99%
450 W336.7 W38.7 V × 8.7 A88.7 W99%
455 W340.5 W38.89 V × 8.76 A89.7 W99%
460 W344.3 W39.07 V × 8.81 A90.7 W99%
465 W348.2 W39.26 V × 8.87 A91.7 W99%
470 W351.7 W39.45 V × 8.92 A92.6 W99%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
52.6 V
Voc when cold
per panel
32.2 V
Vmp when hot
per panel
11
Max panels / string
max DC 600 V
2
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet2–11
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–11
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–11
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window8–9

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V52.6 / 32.2 V✓ Within range1.48
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V52.6 / 32.2 V✗ Not a match: module voltage below MPPT range1.13
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V52.6 / 32.2 V✓ Within range0.55
Enphase IQ8M-72-2-US260–460 W60 V30–45 V52.6 / 32.2 V✓ Within range1.32
Enphase IQ8A-72-2-US295–500 W60 V32–45 V52.6 / 32.2 V✓ Within range1.23
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67672111,5316.08
Palmdale1,83578912,6256.69
Chula Vista1,69672911,6686.11
Huntington Beach1,64370611,3045.89
Riverside1,69672911,6686.21
Santa Clarita1,72474111,8616.28
753Jan753Feb967Mar1,068Apr1,055May1,121Jun1,181Jul1,194Aug1,044Sep921Oct792Nov685DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 430 W panels

CEC PV Module List (Oct 7, 2026) · datasheets · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, AWarrantyPVEL (product / brand)SoCal permits (series)
Shinsung E&G SSV430-144MH-BW430 W≈19.6%−0.37349.211.19———
Canadian Solar CS3N-430MS430 W≈21.8%−0.33245.711.8625 yrproduct 202346
Qcells Q.TRON BLK M-G2+ 430430 W≥22%−0.27639.3213.7425 / 25 yrbrand 11× (2016–2026)40
Silfab Solar SIL-430QD430 W≈22.1%−0.29438.9113.8725 / 30 yrbrand 7× (2017–2025)39
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the Shinsung E&G SSV430-144MH-BW?

Calculated from the panel area (2.19 m²): about 19.6% for the 430 W class. 430 W over 2.19 m² equals about 196 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 721 kWh per year per 430 W panel in Los Angeles and about 789 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.373 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 19.3% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–11 panels per string (Voc at 2 °C = 52.6 V, Vmp at 74 °C cell = 32.2 V). Final design must follow the inverter manual and NEC 690.7.

Does it work with Enphase IQ8PLUS-72-2-US microinverters?

Voltage check against the Enphase datasheet: Voc when cold 52.6 V vs max input 60 V; Vmp when hot 32.2 V vs MPPT low 29 V; recommended module power 235–440 W. Confirm on the microinverter maker’s compatibility list.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Canadian Solar — manufacturer datasheet “HiKu Mono PERC CS3N-400|405|410|415|420|425MS MORE POWER”.
  3. Qcells — manufacturer datasheet “Q.TRON BLK M-G2+ SERIES 415–440 Wp”.
  4. Silfab Solar — datasheet NTC SIL-420 QD CELL TECHNOLOGY.
  5. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
  6. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  7. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  8. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  9. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  10. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).