156 half-cut cells, bifacial, white backsheet. Power classes 570–600 W in the CEC list.
| Model | Pmax | Voc, V | Isc, A | Vmp, V | Imp, A | Efficiency | PTC | CEC listed |
|---|---|---|---|---|---|---|---|---|
| HT78-18X-570 | 570 W | 53.19 | 13.68 | 44.68 | 12.76 | ≈20.4% | 527 W | Aug 11, 2021 |
| HT78-18X-570 {Clr} | 570 W | 53.19 | 13.68 | 44.68 | 12.76 | ≈20.4% | 526 W | Aug 11, 2021 |
| HT78-18X-575 | 575 W | 53.34 | 13.75 | 44.83 | 12.83 | ≈20.5% | 532 W | Aug 11, 2021 |
| HT78-18X-575 {Clr} | 575 W | 53.34 | 13.75 | 44.83 | 12.83 | ≈20.5% | 530 W | Aug 11, 2021 |
| HT78-18X-580 | 580 W | 53.49 | 13.82 | 44.98 | 12.90 | ≈20.7% | 537 W | Aug 11, 2021 |
| HT78-18X-580 {Clr} | 580 W | 53.49 | 13.82 | 44.98 | 12.90 | ≈20.7% | 535 W | Aug 11, 2021 |
| HT78-18X-585 | 585 W | 53.64 | 13.89 | 45.13 | 12.97 | ≈20.9% | 542 W | Aug 11, 2021 |
| HT78-18X-585 {Clr} | 585 W | 53.64 | 13.89 | 45.13 | 12.97 | ≈20.9% | 540 W | Aug 11, 2021 |
| HT78-18X-590 | 590 W | 53.79 | 13.96 | 45.28 | 13.04 | ≈21.1% | 546 W | Aug 11, 2021 |
| HT78-18X-590 {Clr} | 590 W | 53.79 | 13.96 | 45.28 | 13.04 | ≈21.1% | 545 W | Aug 11, 2021 |
| HT78-18X-595 | 595 W | 53.94 | 14.03 | 45.43 | 13.11 | ≈21.3% | 551 W | Aug 11, 2021 |
| HT78-18X-595 {Clr} | 595 W | 53.94 | 14.03 | 45.43 | 13.11 | ≈21.3% | 549 W | Aug 11, 2021 |
| HT78-18X-600 | 600 W | 54.09 | 14.10 | 45.58 | 13.17 | ≈22.1% | 565 W | Aug 21, 2024 |
| CEC listing test | |
|---|---|
| Pmax coefficient γ | −0.373 %/°C |
| Voc coefficient β | −0.255 %/°C |
| Isc coefficient α | +0.035 %/°C |
| Operating cell temperature | NOCT 45.9 °C |
| Class | Pmax at NOCT | Vmp × Imp at NOCT | Pmax at 200 W/m² | Low-light efficiency vs STC |
|---|---|---|---|---|
| 570 W | 433.7 W | 44.88 V × 9.66 A | 110.2 W | 97% |
| 570 W | 425.6 W | 42.65 V × 9.98 A | 111 W | 97% |
| 575 W | 437.5 W | 45.03 V × 9.72 A | 111.2 W | 97% |
| 575 W | 429.4 W | 42.79 V × 10.03 A | 112 W | 97% |
| 580 W | 441.4 W | 45.18 V × 9.77 A | 112.1 W | 97% |
| 580 W | 433.2 W | 42.94 V × 10.09 A | 113 W | 97% |
| 585 W | 445.3 W | 45.33 V × 9.82 A | 113.1 W | 97% |
| 585 W | 437 W | 43.08 V × 10.14 A | 114 W | 97% |
| 590 W | 449.2 W | 45.48 V × 9.88 A | 114.1 W | 97% |
| 590 W | 440.8 W | 43.22 V × 10.2 A | 115 W | 97% |
| 595 W | 453.1 W | 45.64 V × 9.93 A | 115.1 W | 97% |
| 595 W | 444.6 W | 43.36 V × 10.25 A | 116 W | 97% |
| 600 W | 443.2 W | 42.14 V × 10.52 A | 118.3 W | 99% |
| Year | Product | Tests |
|---|---|---|
| 2023 | HT78-18X-xxx | LID+LETIDPID |
| 2024 | HT78-18X-xxx | DHHSSLID+LETIDPID |
| Inverter | Max DC input | MPPT | Window source | Panels per string |
|---|---|---|---|---|
| Tesla 1538000-xx-y | 600 V | 60–480 V | datasheet | 2–10 |
| Solis (Ginlong) S6-EH1P10K-H-US | 600 V | 80–520 V | datasheet | 3–10 |
| Solis (Ginlong) Solis-1P7.6K-4G-US | 600 V | 100–500 V | datasheet | 3–10 |
| Qcells Q.VOLT H7.6SX | 498 V | 234–498 V | CEC test window | 7–8 |
| City | kWh / kW / yr | kWh / panel / yr | kWh / system / yr | Sun, kWh/m²/day |
|---|---|---|---|---|
| Los Angeles | 1,676 | 980 | 11,766 | 6.08 |
| Palmdale | 1,835 | 1,073 | 12,882 | 6.69 |
| Chula Vista | 1,696 | 992 | 11,906 | 6.11 |
| Huntington Beach | 1,643 | 961 | 11,534 | 5.89 |
| Riverside | 1,696 | 992 | 11,906 | 6.21 |
| Santa Clarita | 1,724 | 1,009 | 12,102 | 6.28 |
| Panel | Pmax | Efficiency | γ Pmax (CEC) | Voc, V | Isc, A | PVEL (product / brand) | SoCal permits (series) |
|---|---|---|---|---|---|---|---|
| Shanghai Aerospace Automobile Electromechanical HT78-18X 585 | 585 W | ≈20.9% | −0.373 | 53.64 | 13.89 | product 2023, 2024 | — |
| VSUN (Vietnam Sunergy) VSUN585N-144MH | 585 W | ≈22.7% | −0.309 | 52.25 | 13.88 | brand 6× (2021–2026) | 1 |
| Phono Solar PS585M8GFH-24/TNH | 585 W | ≈22.9% | −0.293 | 52.9 | 13.72 | product 2024, 2025 | 1 |
| Qcells Q.PEAK DUO XL-G11S.3/BFG 585 | 585 W | ≈21.5% | −0.348 | 53.57 | 13.72 | product 2024, 2025, 2026 | 1 |
Calculated from the panel area (2.8 m²): about 20.9% for the 585 W class. 585 W over 2.8 m² equals about 209 W per square meter.
PVWatts v8 with typical-year weather gives about 980 kWh per year per 585 W panel in Los Angeles and about 1,073 kWh in Palmdale (20° roof, facing south, 14% system losses).
With γ = −0.373 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 19.3% below the STC rating.
With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–10 panels per string (Voc at 2 °C = 56.8 V, Vmp at 74 °C cell = 36.1 V). Final design must follow the inverter manual and NEC 690.7.
Yes. Rear gain depends on mounting height and ground reflectance.
HT78-18X-xxx was a PVEL Top Performer in 2023, 2024 (DH, HSS, LID+LETID, PID).