120 half-cut cells, bifacial, white backsheet. Power classes 350–365 W in the CEC list.
| Model | Pmax | Voc, V | Isc, A | Vmp, V | Imp, A | Efficiency | PTC | CEC listed |
|---|---|---|---|---|---|---|---|---|
| HT60-166M-350 | 350 W | 40.70 | 11.33 | 33.30 | 10.53 | ≈19.2% | 328 W | Jul 21, 2021 |
| HT60-166M-350 {Clr} | 350 W | 40.70 | 11.33 | 33.30 | 10.53 | ≈19.2% | 326 W | Aug 11, 2021 |
| HT60-166M-355 | 355 W | 40.90 | 11.43 | 33.50 | 10.61 | ≈19.5% | 333 W | Jul 21, 2021 |
| HT60-166M-355 {Clr} | 355 W | 40.90 | 11.43 | 33.50 | 10.61 | ≈19.5% | 331 W | Aug 11, 2021 |
| HT60-166M-360 | 360 W | 41.10 | 11.53 | 33.70 | 10.69 | ≈19.8% | 337 W | Jul 21, 2021 |
| HT60-166M-360 {Clr} | 360 W | 41.10 | 11.53 | 33.70 | 10.69 | ≈19.8% | 336 W | Aug 11, 2021 |
| HT60-166M-365 | 365 W | 41.30 | 11.63 | 33.90 | 10.77 | ≈20.1% | 342 W | Jul 21, 2021 |
| HT60-166M-365 {Clr} | 365 W | 41.30 | 11.63 | 33.90 | 10.77 | ≈20.0% | 341 W | Aug 11, 2021 |
| CEC listing test | |
|---|---|
| Pmax coefficient γ | −0.330 %/°C |
| Voc coefficient β | −0.290 %/°C |
| Isc coefficient α | +0.045 %/°C |
| Operating cell temperature | NOCT 44.6 °C |
| Class | Pmax at NOCT | Vmp × Imp at NOCT | Pmax at 200 W/m² | Low-light efficiency vs STC |
|---|---|---|---|---|
| 350 W | 255 W | 32.33 V × 7.89 A | 64.6 W | 92% |
| 350 W | 259.9 W | 32.51 V × 7.99 A | 65.3 W | 93% |
| 355 W | 258.5 W | 32.53 V × 7.95 A | 65.5 W | 92% |
| 355 W | 263.4 W | 32.71 V × 8.05 A | 66.2 W | 93% |
| 360 W | 262 W | 32.72 V × 8.01 A | 66.4 W | 92% |
| 360 W | 267 W | 32.9 V × 8.11 A | 67.1 W | 93% |
| 365 W | 265.5 W | 32.92 V × 8.07 A | 67.2 W | 92% |
| 365 W | 270.6 W | 33.1 V × 8.18 A | 68 W | 93% |
| Inverter | Max DC input | MPPT | Window source | Panels per string |
|---|---|---|---|---|
| Tesla 1538000-xx-y | 600 V | 60–480 V | datasheet | 3–13 |
| Solis (Ginlong) S6-EH1P10K-H-US | 600 V | 80–520 V | datasheet | 3–13 |
| Solis (Ginlong) Solis-1P7.6K-4G-US | 600 V | 100–500 V | datasheet | 4–13 |
| Qcells Q.VOLT H7.6SX | 498 V | 234–498 V | CEC test window | 9–11 |
| Microinverter | Recommended module power | Max DC input | MPPT | Voc cold / Vmp hot | Check | DC/AC |
|---|---|---|---|---|---|---|
| Enphase IQ8PLUS-72-2-US | 235–440 W | 60 V | 29–45 V | 43.6 / 27.3 V | ⚠ Works; below MPPT at peak heat | 1.22 |
| Enphase IQ8X-80-M-US | 320–540 W | 79.5 V | 43–60 V | 43.6 / 27.3 V | ✗ Not a match: module voltage below MPPT range | 0.93 |
| APsystems (Alt Power System) DS3-L | 265–570 W | 60 V | 28–45 V | 43.6 / 27.3 V | ⚠ Works; below MPPT at peak heat | 0.46 |
| Enphase IQ8M-72-2-US | 260–460 W | 60 V | 30–45 V | 43.6 / 27.3 V | ⚠ Works; below MPPT at peak heat | 1.09 |
| Enphase IQ8A-72-2-US | 295–500 W | 60 V | 32–45 V | 43.6 / 27.3 V | ⚠ Works; below MPPT at peak heat | 1.02 |
| City | kWh / kW / yr | kWh / panel / yr | kWh / system / yr | Sun, kWh/m²/day |
|---|---|---|---|---|
| Los Angeles | 1,676 | 595 | 11,900 | 6.08 |
| Palmdale | 1,835 | 651 | 13,028 | 6.69 |
| Chula Vista | 1,696 | 602 | 12,042 | 6.11 |
| Huntington Beach | 1,643 | 583 | 11,665 | 5.89 |
| Riverside | 1,696 | 602 | 12,042 | 6.21 |
| Santa Clarita | 1,724 | 612 | 12,240 | 6.28 |
| Panel | Pmax | Efficiency | γ Pmax (CEC) | Voc, V | Isc, A | PVEL (product / brand) | SoCal permits (series) |
|---|---|---|---|---|---|---|---|
| Shanghai Aerospace Automobile Electromechanical HT60-166M 355 | 355 W | ≈19.5% | −0.330 | 40.9 | 11.43 | brand 8× | — |
| LONGi LR4-60HPB-355M | 355 W | ≈20.1% | −0.339 | 40.6 | 11.25 | product 2021, 2022 | 193 |
| REC Group REC355AA | 355 W | ≈21.1% | −0.279 | 44 | 10.19 | brand 9× (2016–2025) | 30 |
| Trina Solar TSM-355DE06X.05(II) | 355 W | ≈19.5% | −0.339 | 44.6 | 10.24 | product 2022 | 23 |
Calculated from the panel area (1.82 m²): about 19.5% for the 355 W class. 355 W over 1.82 m² equals about 195 W per square meter.
PVWatts v8 with typical-year weather gives about 595 kWh per year per 355 W panel in Los Angeles and about 651 kWh in Palmdale (20° roof, facing south, 14% system losses).
With γ = −0.330 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 17.1% below the STC rating.
With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–13 panels per string (Voc at 2 °C = 43.6 V, Vmp at 74 °C cell = 27.3 V). Final design must follow the inverter manual and NEC 690.7.
Yes. Rear gain depends on mounting height and ground reflectance.
This exact series is not in published PVEL Top Performer tables; Shanghai Aerospace Automobile Electromechanical was named a Top Performer in 8 Scorecards (2018–2026).