Solar panelSeraphim

Seraphim SRP-455-BTE-BG

96 half-cut cells, bifacial, glass (dual-glass module). Power classes 440–470 W in the CEC list.

CEC listed · Jan 2, 2026UL 61730BifacialPVEL Top Performer 2025
Power class
  • Power (STC)455 WCEC nameplate
  • Efficiency≈22.9%calculated from area
  • %/°C Pmax−0.324CEC listing test
  • PTC / STC93.9%PTC 427 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 7 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
SRP-440-BTE-BG440 W35.3815.8029.4114.97≈22.1%413 WJan 2, 2026
SRP-445-BTE-BG445 W35.5815.8529.6115.03≈22.4%418 WJan 2, 2026
SRP-450-BTE-BG450 W35.7815.9029.8115.10≈22.6%422 WJan 2, 2026
SRP-455-BTE-BG455 W35.9815.9530.0115.17≈22.9%427 WJan 2, 2026
SRP-460-BTE-BG460 W36.1816.0030.2115.23≈23.1%432 WJan 2, 2026
SRP-465-BTE-BG465 W36.3816.0530.4115.30≈23.4%437 WMar 23, 2026
SRP-470-BTE-BG470 W36.5816.1030.6115.36≈23.6%442 WMar 23, 2026
≈ efficiency = Pmax ÷ CEC-listed area 1.99 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.324 %/°C
Voc coefficient β−0.302 %/°C
Isc coefficient α+0.052 %/°C
Operating cell temperatureNOCT 45.6 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
440 W330.3 W27.38 V × 12.06 A86.9 W99%
445 W333.9 W27.56 V × 12.11 A87.8 W99%
450 W337.7 W27.75 V × 12.17 A88.8 W99%
455 W341.5 W27.94 V × 12.22 A89.8 W99%
460 W345.2 W28.12 V × 12.27 A90.8 W99%
465 W349 W28.31 V × 12.33 A91.8 W99%
470 W352.7 W28.5 V × 12.38 A92.8 W99%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Certifications

CEC PV Module List (Oct 7, 2026) · Clean Energy Council (Australia)
UL 61730IEC 61215:2021 / IEC 61730:2023

Independent reliability testing

Kiwa PVEL Scorecard
2025
PVEL Top Performer
this series
6
Tests passed as Top Performer
DH, HSS, LID+LETID, MSS, PID, TC
6
PVEL Scorecards
Seraphim named Top Performer, 2017–2025

PVEL Top Performer tests

YearProductTests
2025SRP-xxx-BTE-BGDHHSSLID+LETIDMSSPIDTC
2025SRP-xxx-BTE-BG (Full Black) (closely related product name)DHHSSLID+LETIDMSSTC

Tested bill of materials

Details describe the tested sample, not every module of the series.

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
38.5 V
Voc when cold
per panel
24.5 V
Vmp when hot
per panel
15
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–15
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet4–15
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet5–15
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window10–12

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V38.5 / 24.5 V✗ Not a match: module voltage below MPPT range1.2
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V38.5 / 24.5 V⚠ Works; below MPPT at peak heat0.58
Enphase IQ8M-72-2-US260–460 W60 V30–45 V38.5 / 24.5 V⚠ Works; below MPPT at peak heat1.4
Enphase IQ8A-72-2-US295–500 W60 V32–45 V38.5 / 24.5 V✗ Not a match: module voltage below MPPT range1.3
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67676311,4396.08
Palmdale1,83583512,5246.69
Chula Vista1,69677211,5756.11
Huntington Beach1,64374811,2135.89
Riverside1,69677211,5756.21
Santa Clarita1,72478411,7666.28
747Jan747Feb959Mar1,059Apr1,046May1,112Jun1,171Jul1,185Aug1,036Sep914Oct786Nov680DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 455 W panels

CEC PV Module List (Oct 7, 2026) · datasheets · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
Seraphim SRP-455-BTE-BG455 W≈22.9%−0.32435.9815.95product 2025—
Hyundai Energy Solutions HiN-T450NF(BK)450 W≈23.2%−0.29839.214.53brand 5× (2017–2025)37
REC Group REC455AA Pure-RX455 W≈22.5%−0.24865.68.84brand 9× (2016–2025)33
Aptos Solar DNA-120-MF10-455W455 W≈21%−0.36341.513.93—22
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

About Seraphim

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard

Other series by SoCal permits

SRP-xxx-BTA-BGSRP-xxx-BTC-BGSRP-xxx-BTD-BGSRP-xxx-BMA-BGSRP-xxx-BMA-HVSRP-xxx-BMD-HV

Questions & answers

How efficient is the Seraphim SRP-455-BTE-BG?

Calculated from the panel area (1.99 m²): about 22.9% for the 455 W class. 455 W over 1.99 m² equals about 229 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 763 kWh per year per 455 W panel in Los Angeles and about 835 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.324 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 16.8% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–15 panels per string (Voc at 2 °C = 38.5 V, Vmp at 74 °C cell = 24.5 V). Final design must follow the inverter manual and NEC 690.7.

Is it bifacial?

Yes. Rear gain depends on mounting height and ground reflectance.

Has this panel been reliability-tested?

SRP-xxx-BTE-BG was a PVEL Top Performer in 2025 (DH, HSS, LID+LETID, MSS, PID, TC).

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Hyundai Energy Solutions — datasheet [US] NF(BK)(HiN) Series (N TOPCon Bifacial) 435~445W.
  3. Aptos Solar — datasheet Legacy Products.
  4. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2017–2025.
  5. NLR (formerly NREL) — System Advisor Model CEC module and inverter libraries (version 2026.7.3).
  6. Clean Energy Council (Australia) — Approved PV modules list (as of Oct 8, 2026).
  7. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  8. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  9. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  10. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).