Solar panelSeraphim

Seraphim SRP-440-BTD-BG

108 half-cut cells, bifacial, glass (dual-glass module). Power classes 430–460 W in the CEC list.

CEC listed · Jan 2, 2026UL 61730BifacialPVEL Top Performer 2025
Power class
  • Power (STC)440 WCEC nameplate
  • Efficiency≈22.6%calculated from area
  • %/°C Pmax−0.284CEC listing test
  • PTC / STC94.5%PTC 416 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 7 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
SRP-430-BTD-BG430 W38.9013.9932.3013.32≈22.1%406 WJan 2, 2026
SRP-435-BTD-BG435 W39.1014.0732.5013.39≈22.3%411 WJan 2, 2026
SRP-440-BTD-BG440 W39.3014.1532.7013.47≈22.6%416 WJan 2, 2026
SRP-445-BTD-BG445 W39.5014.2332.9013.54≈22.8%420 WMar 23, 2026
SRP-450-BTD-BG450 W39.7014.3133.1013.60≈23.1%425 WMar 23, 2026
SRP-455-BTD-BG455 W39.9014.3933.3013.67≈23.3%430 WMar 23, 2026
SRP-460-BTD-BG460 W40.1014.4733.5013.73≈23.6%435 WMar 23, 2026
≈ efficiency = Pmax ÷ CEC-listed area 1.95 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.284 %/°C
Voc coefficient β−0.236 %/°C
Isc coefficient α+0.044 %/°C
Operating cell temperatureNOCT 46.2 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
430 W319.8 W31.79 V × 10.06 A84.6 W98%
435 W323.5 W31.99 V × 10.11 A85.6 W98%
440 W327.5 W32.19 V × 10.17 A86.6 W98%
445 W331.2 W32.38 V × 10.23 A87.6 W98%
450 W334.7 W32.58 V × 10.27 A88.5 W98%
455 W338.4 W32.78 V × 10.33 A89.5 W98%
460 W341.9 W32.97 V × 10.37 A90.5 W98%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Certifications

CEC PV Module List (Oct 7, 2026) · Clean Energy Council (Australia)
UL 61730IEC 61215:2021 / IEC 61730:2023

Independent reliability testing

Kiwa PVEL Scorecard
2025
PVEL Top Performer
this series
6
Tests passed as Top Performer
DH, HSS, LID+LETID, MSS, PID, TC
6
PVEL Scorecards
Seraphim named Top Performer, 2017–2025

PVEL Top Performer tests

YearProductTests
2025SRP-xxx-BTD-BGDHHSSLID+LETIDMSSPIDTC

Tested bill of materials

Details describe the tested sample, not every module of the series.

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
41.4 V
Voc when cold
per panel
27.4 V
Vmp when hot
per panel
14
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–14
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–14
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–14
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window9–12

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V41.4 / 27.4 V⚠ Works; below MPPT at peak heat1.52
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V41.4 / 27.4 V✗ Not a match: module voltage below MPPT range1.16
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V41.4 / 27.4 V⚠ Works; below MPPT at peak heat0.56
Enphase IQ8M-72-2-US260–460 W60 V30–45 V41.4 / 27.4 V⚠ Works; below MPPT at peak heat1.35
Enphase IQ8A-72-2-US295–500 W60 V32–45 V41.4 / 27.4 V⚠ Works; below MPPT at peak heat1.26
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67673711,7996.08
Palmdale1,83580712,9186.69
Chula Vista1,69674611,9406.11
Huntington Beach1,64372311,5675.89
Riverside1,69674611,9406.21
Santa Clarita1,72475912,1376.28
770Jan771Feb989Mar1,093Apr1,079May1,147Jun1,208Jul1,222Aug1,069Sep943Oct810Nov701DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 440 W panels

CEC PV Module List (Oct 7, 2026) · datasheets · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, AWarrantyPVEL (product / brand)SoCal permits (series)
Seraphim SRP-440-BTD-BG440 W≈22.6%−0.28439.314.15—product 2025—
Qcells Q.TRON BLK M-G2+ 440440 W≥22.5%−0.27639.8813.925 / 25 yrbrand 11× (2016–2026)40
Silfab Solar SIL-440QD440 W≈22.6%−0.29438.9714.2525 / 30 yrbrand 7× (2017–2025)39
Hyundai Energy Solutions HiN-T440NF(BK)440 W≈22.7%−0.29838.814.3925 / 30 yrbrand 5× (2017–2025)37
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

About Seraphim

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard

Other series by SoCal permits

SRP-xxx-BTA-BGSRP-xxx-BTC-BGSRP-xxx-BTE-BGSRP-xxx-BMA-BGSRP-xxx-BMA-HVSRP-xxx-BMD-HV

Questions & answers

How efficient is the Seraphim SRP-440-BTD-BG?

Calculated from the panel area (1.95 m²): about 22.6% for the 440 W class. 440 W over 1.95 m² equals about 226 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 737 kWh per year per 440 W panel in Los Angeles and about 807 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.284 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 14.7% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–14 panels per string (Voc at 2 °C = 41.4 V, Vmp at 74 °C cell = 27.4 V). Final design must follow the inverter manual and NEC 690.7.

Is it bifacial?

Yes. Rear gain depends on mounting height and ground reflectance.

Has this panel been reliability-tested?

SRP-xxx-BTD-BG was a PVEL Top Performer in 2025 (DH, HSS, LID+LETID, MSS, PID, TC).

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Qcells — manufacturer datasheet “Q.TRON BLK M-G2+ SERIES 415–440 Wp”.
  3. Silfab Solar — datasheet NTC SIL-420 QD CELL TECHNOLOGY.
  4. Hyundai Energy Solutions — datasheet [US] NF(BK)(HiN) Series (N TOPCon Bifacial) 435~445W.
  5. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2017–2025.
  6. NLR (formerly NREL) — System Advisor Model CEC module and inverter libraries (version 2026.7.3).
  7. Clean Energy Council (Australia) — Approved PV modules list (as of Oct 8, 2026).
  8. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  9. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  10. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  11. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).