Cali-GrafCali-Graf
Solar panelSEG Solar

SEG Solar SEG-630-BTZ-BG

156 half-cut cells, bifacial, glass (dual-glass module). Power classes 620–640 W in the CEC list.

CEC listed · Oct 1, 2024UL 61730BifacialPVEL Top Performer 2024
Power class
  • Power (STC)630 WCEC nameplate
  • Efficiency≈22.8%calculated from area
  • %/°C Pmax−0.337CEC listing test
  • PTC / STC94.4%PTC 595 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 5 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
SEG-620-BTZ-BG620 W56.8213.7447.3713.09≈22.5%585 WOct 1, 2024
SEG-625-BTZ-BG625 W56.9513.8047.5413.15≈22.6%590 WOct 1, 2024
SEG-630-BTZ-BG630 W57.0813.8647.7013.21≈22.8%595 WOct 1, 2024
SEG-635-BTZ-BG635 W57.2113.9247.8613.27≈23.0%600 WOct 1, 2024
SEG-640-BTZ-BG640 W57.3413.9848.0213.33≈23.2%604 WOct 1, 2024
≈ efficiency = Pmax ÷ CEC-listed area 2.76 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.337 %/°C
Voc coefficient β−0.234 %/°C
Isc coefficient α+0.046 %/°C
Operating cell temperatureNOCT 43.2 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
620 W466.7 W44.35 V × 10.52 A119.5 W96%
625 W470.5 W44.51 V × 10.57 A120.5 W96%
630 W474.2 W44.66 V × 10.62 A121.4 W96%
635 W478 W44.81 V × 10.67 A122.4 W96%
640 W481.8 W44.96 V × 10.71 A123.4 W96%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Independent reliability testing

Kiwa PVEL Scorecard · RETC PV Module Index
2024
PVEL Top Performer
this series
3
Tests passed as Top Performer
DH, LID+LETID, PID
5
PVEL Scorecards
SEG Solar named Top Performer, 2022–2026
2
RETC PV Module Index
SEG Solar recognized 2023–2024

PVEL Top Performer tests

YearProductTests
2024SEG-xxx-BTZ-BGDHLID+LETIDPID

Tested bill of materials

Details describe the tested sample, not every module of the series.

RETC PV Module Index — SEG Solar

YearRecognition
2023High Achievement in Performance (LeTID RESISTANCE)
2024Test Category High Achiever

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
60.2 V
Voc when cold
per panel
38.8 V
Vmp when hot
per panel
9
Max panels / string
max DC 600 V
2
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet2–9
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–9
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet3–9
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window7–8

Microinverters (one per panel)

No microinverter in the reference set lists this power class in its recommended module power range.
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,6761,05611,6156.08
Palmdale1,8351,15612,7176.69
Chula Vista1,6961,06811,7536.11
Huntington Beach1,6431,03511,3865.89
Riverside1,6961,06811,7536.21
Santa Clarita1,7241,08611,9476.28
758Jan759Feb974Mar1,076Apr1,062May1,129Jun1,189Jul1,203Aug1,052Sep928Oct798Nov690DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 630 W panels

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · datasheets
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)
SEG Solar SEG-630-BTZ-BG630 W≈22.8%−0.33757.0813.86product 2024
Canadian Solar CS7N-630MB-AG630 W≈20.5%−0.39044.218.23product 2024
Hyundai Energy Solutions HiS-T630NJ630 W≈22.8%−0.29457.3613.9brand 5× (2017–2025)
Waaree BiN-17-630630 W≥22.5%−0.30857.0213.94product 2025, 2026
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

About SEG Solar

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · RETC PV Module Index · building permits

Other series by SoCal permits

SEG-xxx-BMD-HV · 20SEG-xxx-BTD-BG · 8SEG-xxx-BHC-BGSEG-xxx-BTA-BGSEG-xxx-BTA-HVSEG-xxx-BTB-BG

Questions & answers

How efficient is the SEG Solar SEG-630-BTZ-BG?

Calculated from the panel area (2.76 m²): about 22.8% for the 630 W class. 630 W over 2.76 m² equals about 228 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 1,056 kWh per year per 630 W panel in Los Angeles and about 1,156 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.337 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 17.4% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–9 panels per string (Voc at 2 °C = 60.2 V, Vmp at 74 °C cell = 38.8 V). Final design must follow the inverter manual and NEC 690.7.

Is it bifacial?

Yes. Rear gain depends on mounting height and ground reflectance.

Has this panel been reliability-tested?

SEG-xxx-BTZ-BG was a PVEL Top Performer in 2024 (DH, LID+LETID, PID).

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Hyundai Energy Solutions — datasheet [US] NJ(HiS) Series (N TOPCon Bifacial) 635~645W.
  3. Waaree — datasheet ELITE SERIES BiN-17-615-645 WEL-EPD-615-645-156-BiN-HC-04-27.05.2024 35mm.
  4. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2022–2026.
  5. RETC — PV Module Index reports 2023–2024.
  6. NLR (formerly NREL) — System Advisor Model CEC module and inverter libraries (version 2026.7.3).
  7. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  8. Inverter datasheets — Solis (Ginlong), Tesla (manufacturer documents).
  9. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  10. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).