SEG Solar SEG-495-BTB-HV

120 half-cut cells, bifacial. Power classes 485–510 W in the CEC list.

CEC listed · May 21, 2026UL 61730Bifacial
Power class
  • Power (STC)495 WCEC nameplate
  • Efficiency≈23.6%calculated from area
  • %/°C Pmax−0.272CEC listing test
  • PTC / STC95.5%PTC 472 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 6 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
SEG-485-BTB-HV485 W43.4713.9136.8513.16≈23.1%463 WMay 21, 2026
SEG-490-BTB-HV490 W43.6413.9537.0313.23≈23.3%468 WMay 21, 2026
SEG-495-BTB-HV495 W43.8214.0037.2013.31≈23.6%472 WMay 21, 2026
SEG-500-BTB-HV500 W44.0014.0437.3813.38≈23.8%477 WMay 21, 2026
SEG-505-BTB-HV505 W44.1814.1137.5513.45≈24.0%482 WMay 21, 2026
SEG-510-BTB-HV510 W44.3814.1737.7513.51≈24.3%487 WMay 21, 2026
≈ efficiency = Pmax ÷ CEC-listed area 2.1 m².

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.272 %/°C
Voc coefficient β−0.235 %/°C
Isc coefficient α+0.040 %/°C
Operating cell temperatureNOCT 43.5 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
485 W367 W35.11 V × 10.45 A92.5 W95%
490 W370.7 W35.28 V × 10.51 A93.5 W95%
495 W374.7 W35.45 V × 10.57 A94.5 W95%
500 W378.5 W35.62 V × 10.63 A95.4 W95%
505 W382.2 W35.78 V × 10.68 A96.4 W95%
510 W386 W35.97 V × 10.73 A97.3 W95%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Independent reliability testing

Kiwa PVEL Scorecard · RETC PV Module Index
5
PVEL Scorecards
SEG Solar named Top Performer, 2022–2026
2
RETC PV Module Index
SEG Solar recognized 2023–2024
This exact series is not listed in published PVEL Top Performer tables. Results below are for the manufacturer.

RETC PV Module Index — SEG Solar

YearRecognition
2023High Achievement in Performance (LeTID RESISTANCE)
2024Test Category High Achiever

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
46.2 V
Voc when cold
per panel
31.5 V
Vmp when hot
per panel
12
Max panels / string
max DC 600 V
2
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet2–12
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–12
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–12
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window8–10

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V46.2 / 31.5 V✗ Not a match: module voltage below MPPT range1.3
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V46.2 / 31.5 V✓ Within range0.63
Enphase IQ8A-72-2-US295–500 W60 V32–45 V46.2 / 31.5 V⚠ Works; below MPPT at peak heat1.42
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67683011,6156.08
Palmdale1,83590812,7176.69
Chula Vista1,69684011,7536.11
Huntington Beach1,64381311,3865.89
Riverside1,69684011,7536.21
Santa Clarita1,72485311,9476.28
758Jan759Feb974Mar1,076Apr1,062May1,129Jun1,189Jul1,203Aug1,052Sep928Oct798Nov690DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 495 W panels

CEC PV Module List (Oct 7, 2026) · datasheets · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, ASoCal permits (series)
SEG Solar SEG-495-BTB-HV495 W≈23.6%−0.27243.8214—
Qcells Q.PEAK DUO XL-G10.d 495495 W≥21.4%−0.34053.7111.346
AXITEC AC-530MH/144V530 W≥20.5%−0.36649.313.721
La Solar LS530BL530 W≈20.5%−0.34249.313.61
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

About SEG Solar

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · RETC PV Module Index · building permits

Other series by SoCal permits

SEG-xxx-BMD-HV · 20SEG-xxx-BTD-BG · 8SEG-xxx-BHC-BGSEG-xxx-BTA-BGSEG-xxx-BTA-HVSEG-xxx-BTB-BG

Questions & answers

How efficient is the SEG Solar SEG-495-BTB-HV?

Calculated from the panel area (2.1 m²): about 23.6% for the 495 W class. 495 W over 2.1 m² equals about 236 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 830 kWh per year per 495 W panel in Los Angeles and about 908 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.272 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 14.1% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–12 panels per string (Voc at 2 °C = 46.2 V, Vmp at 74 °C cell = 31.5 V). Final design must follow the inverter manual and NEC 690.7.

Does it work with APsystems (Alt Power System) DS3-L microinverters?

Voltage check against the APsystems (Alt Power System) datasheet: Voc when cold 46.2 V vs max input 60 V; Vmp when hot 31.5 V vs MPPT low 28 V; recommended module power 265–570 W. Confirm on the microinverter maker’s compatibility list.

Is it bifacial?

Yes. Rear gain depends on mounting height and ground reflectance.

Has this panel been reliability-tested?

This exact series is not in published PVEL Top Performer tables; SEG Solar was named a Top Performer in 5 Scorecards (2022–2026).

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Qcells — manufacturer datasheet “Q.PEAK DUO XL-G10.d ENDURING HIGH PERFORMANCE”.
  3. AXITEC — datasheet AXIworldbipremium bifacial 144 cells asemmbled in US.
  4. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2022–2026.
  5. RETC — PV Module Index reports 2023–2024.
  6. NLR (formerly NREL) — System Advisor Model CEC module and inverter libraries (version 2026.7.3).
  7. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  8. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  9. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  10. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).