SEG Solar SEG-400-BMD-HV

108 half-cut cells, PERC. Power classes 390–415 W in the CEC list; datasheet covers 405–420 W.

CEC listed · Aug 23, 2021UL 61730PERCInstalled in 20 SoCal permits
Power class
  • Power (STC)400 WCEC nameplate
  • Efficiency≈20.5%calculated from area
  • %/°C Pmax−0.361CEC listing test
  • PTC / STC93%PTC 372 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · SEG Solar datasheet · 6 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
SEG-390-BMD-HV390 W36.9013.4030.5912.78≈20.0%362 WAug 23, 2021
SEG-395-BMD-HV395 W37.0113.5030.6912.88≈20.2%367 WAug 23, 2021
SEG-400-BMD-HV400 W37.1213.6030.8112.99≈20.5%372 WAug 23, 2021
SEG-405-BMD-HV405 W37.2213.7030.9313.10≥20.7%376 WAug 23, 2021
SEG-410-BMD-HV410 W37.3213.8031.0513.21≥21.0%381 WAug 23, 2021
SEG-415-BMD-HV415 W37.4213.9031.1613.32≥21.2%386 WAug 23, 2021
≈ efficiency = Pmax ÷ panel area 1.953 m² (datasheet size) for classes outside the datasheet.

Build & dimensions

SEG Solar datasheet · Cali-Graf calculation · CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · SEG Solar datasheet
DatasheetCEC listing test
Pmax coefficient γ—−0.361 %/°C
Voc coefficient β—−0.276 %/°C
Isc coefficient α—+0.006 %/°C
Vmp coefficient≈ −0.37 %/°C—
Operating cell temperatureNMOT 45 °CNOCT 45.4 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

At normal operating conditions (NOCT, 800 W/m²) — datasheet

ClassPmax, WVoc, VIsc, AVmp, VImp, A
405 W304.034.7311.0728.9110.51
410 W308.034.8111.1529.0510.59
415 W311.034.9011.2329.1910.66

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
390 W287.7 W28.71 V × 10.02 A77.2 W99%
395 W290.9 W28.81 V × 10.1 A78 W99%
400 W294.6 W28.92 V × 10.19 A79 W99%
405 W298.2 W29.03 V × 10.27 A80 W99%
410 W301.9 W29.15 V × 10.36 A81 W99%
415 W305.5 W29.25 V × 10.44 A81.9 W99%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Electrical & strength ratings

SEG Solar datasheet
Packaging: 31 per pallet · 186 per container

Certifications

CEC PV Module List (Oct 7, 2026) · SEG Solar datasheet
UL 61730UL 1703IEC 61215IEC 61730IEC 61701IEC 62716IEC 62804Fire rating Type 1 (UL 61730)ISO 14001ISO 45001ISO 9001

Independent reliability testing

Kiwa PVEL Scorecard · RETC PV Module Index
5
PVEL Scorecards
SEG Solar named Top Performer, 2022–2026
2
RETC PV Module Index
SEG Solar recognized 2023–2024
This exact series is not listed in published PVEL Top Performer tables. Results below are for the manufacturer.

RETC PV Module Index — SEG Solar

YearRecognition
2023High Achievement in Performance (LeTID RESISTANCE)
2024Test Category High Achiever

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
39.5 V
Voc when cold
per panel
25.3 V
Vmp when hot
per panel
15
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–15
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet4–15
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–15
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window10–12

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V39.5 / 25.3 V⚠ Works; below MPPT at peak heat1.38
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V39.5 / 25.3 V✗ Not a match: module voltage below MPPT range1.05
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V39.5 / 25.3 V⚠ Works; below MPPT at peak heat0.51
Enphase IQ8M-72-2-US260–460 W60 V30–45 V39.5 / 25.3 V⚠ Works; below MPPT at peak heat1.23
Enphase IQ8A-72-2-US295–500 W60 V32–45 V39.5 / 25.3 V✗ Not a match: module voltage below MPPT range1.15
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67667012,0676.08
Palmdale1,83573413,2126.69
Chula Vista1,69667812,2116.11
Huntington Beach1,64365711,8305.89
Riverside1,69667812,2116.21
Santa Clarita1,72469012,4136.28
788Jan788Feb1,012Mar1,117Apr1,104May1,173Jun1,236Jul1,250Aug1,093Sep964Oct829Nov717DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Who installs SEG-xxx-BMD-HV panels in SoCal

building permits
20
Permits naming this series
Aug 2022 – Apr 2024
1
Jurisdictions so far
LA County (unincorp.) (20)

Permits over time

2Aug ’2200Oct13Dec11Feb03Apr32Jun10Aug00Oct00Dec00Feb21Aprpermits per month

Top ZIP codes

  • ZIP 917024
  • ZIP 917243
  • ZIP 910013
  • ZIP 906043
  • Other ZIP codes7

Typical system

median 7.6 kW, 19 panels (n = 17)

Only installer and ZIP level is shown — no homeowner names, street addresses or permit numbers. Permits from LA County (unincorp.) come without a contractor license, so they count toward totals but not toward installers. Counts grow as more permit portals are loaded.

Installed together with

building permits

Microinverters

Enphase IQ8+
12
Enphase IQ8M
3

Inverters

SolarEdge SE…H (HD-Wave)
4

Optimizers

SolarEdge Power Optimizer
2

Batteries

Enphase (model not specified)
2
Number of permits naming both this panel series and the product; 19 of 20 permits list other equipment.

Compare with similar 400 W panels

CEC PV Module List (Oct 7, 2026) · Qcells datasheet · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
SEG Solar SEG-400-BMD-HV400 W≈20.5%−0.36137.1213.6brand 5×20
Qcells Q.PEAK DUO BLK ML-G10+ 400400 W≥20.4%−0.36245.311.14product 2022, 2023221
JA Solar JAM54S31-400/MR400 W≈21.1%−0.32937.0713.79product 2023, 2024152
REC Group REC400AA Pure400 W≈22.3%−0.25648.810.25brand 9× (2016–2025)66
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

About SEG Solar

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · RETC PV Module Index · building permits

Other series by SoCal permits

SEG-xxx-BTD-BG · 8SEG-xxx-BHC-BGSEG-xxx-BTA-BGSEG-xxx-BTA-HVSEG-xxx-BTB-BGSEG-xxx-BTB-HV

Questions & answers

How efficient is the SEG Solar SEG-400-BMD-HV?

Calculated from the panel area (1.95 m²): about 20.5% for the 400 W class. 400 W over 1.95 m² equals about 205 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 670 kWh per year per 400 W panel in Los Angeles and about 734 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.361 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 18.7% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–15 panels per string (Voc at 2 °C = 39.5 V, Vmp at 74 °C cell = 25.3 V). Final design must follow the inverter manual and NEC 690.7.

How big and heavy is it?

67.8 × 44.6 × 1.38 in (1,722 × 1,134 × 35 mm), 47.4 lb (21.5 kg).

Has this panel been reliability-tested?

This exact series is not in published PVEL Top Performer tables; SEG Solar was named a Top Performer in 5 Scorecards (2022–2026).

What fire rating does it have?

UL 61730 fire rating Type 1 per datasheet.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. SEG Solar — manufacturer datasheet “SEG SOLAR INC. (SEG) V SERIES PRODUCT CERTIFICATION”.
  3. Qcells — manufacturer datasheet “Q.PEAK DUO BLK ML-G10+ ENDURING HIGH PERFORMANCE”.
  4. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2022–2026.
  5. RETC — PV Module Index reports 2023–2024.
  6. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  7. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  8. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  9. Building permits — Los Angeles County Public Works (EPIC-LA, unincorporated areas) (Aug 2022 – Apr 2024). Equipment matched from permit descriptions by model number.
  10. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).