Cali-GrafCali-Graf
Solar panelSEG Solar

SEG Solar SEG-445-BMB-TB

120 half-cut cells. Power classes 415–475 W in the CEC list.

CEC listed · Jan 3, 2023UL 61730
Power class
  • Power (STC)445 WCEC nameplate
  • Efficiency≈20.6%calculated from area
  • %/°C Pmax−0.358CEC listing test
  • PTC / STC93.7%PTC 417 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 13 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
SEG-415-BMB-TB415 W40.6213.0633.5512.39≈19.2%388 WJan 3, 2023
SEG-420-BMB-TB420 W40.7213.1633.6312.51≈19.4%393 WJan 3, 2023
SEG-425-BMB-TB425 W40.8213.2533.7712.61≈19.7%398 WJan 3, 2023
SEG-430-BMB-TB430 W40.9213.3633.8512.72≈19.9%403 WJan 3, 2023
SEG-435-BMB-TB435 W41.0113.4533.9812.82≈20.1%407 WJan 3, 2023
SEG-440-BMB-TB440 W41.1213.5634.0812.92≈20.4%412 WJan 3, 2023
SEG-445-BMB-TB445 W41.2213.6634.1813.03≈20.6%417 WJan 3, 2023
SEG-450-BMB-TB450 W41.3213.7634.2813.13≈20.8%422 WJan 3, 2023
SEG-455-BMB-TB455 W41.4213.8634.3913.24≈21.1%427 WJan 3, 2023
SEG-460-BMB-TB460 W41.5213.9634.4913.34≈21.3%431 WJan 3, 2023
SEG-465-BMB-TB465 W41.6214.0634.6013.44≈21.5%434 WMay 22, 2023
SEG-470-BMB-TB470 W41.7214.1634.7013.55≈21.8%439 WMay 22, 2023
SEG-475-BMB-TB475 W41.8314.2634.8013.65≈22.0%444 WMay 22, 2023
≈ efficiency = Pmax ÷ CEC-listed area 2.16 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.358 %/°C
Voc coefficient β−0.262 %/°C
Isc coefficient α+0.037 %/°C
Operating cell temperatureNOCT 43.4 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
415 W306.3 W31.38 V × 9.76 A81.5 W98%
420 W310 W31.46 V × 9.85 A82.4 W98%
425 W313.7 W31.59 V × 9.93 A83.5 W98%
430 W317.2 W31.66 V × 10.02 A84.4 W98%
435 W320.9 W31.79 V × 10.1 A85.4 W98%
440 W324.4 W31.88 V × 10.18 A86.3 W98%
445 W328.1 W31.97 V × 10.26 A87.3 W98%
450 W331.6 W32.07 V × 10.34 A88.2 W98%
455 W335.5 W32.17 V × 10.43 A89.2 W98%
460 W339 W32.26 V × 10.51 A90.2 W98%
465 W345.2 W38.94 V × 8.86 A87.5 W94%
470 W341.3 W38.76 V × 8.81 A86.5 W92%
475 W337.5 W38.57 V × 8.75 A85.5 W90%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Independent reliability testing

Kiwa PVEL Scorecard · RETC PV Module Index
5
PVEL Scorecards
SEG Solar named Top Performer, 2022–2026
2
RETC PV Module Index
SEG Solar recognized 2023–2024
This exact series is not listed in published PVEL Top Performer tables. Results below are for the manufacturer.

RETC PV Module Index — SEG Solar

YearRecognition
2023High Achievement in Performance (LeTID RESISTANCE)
2024Test Category High Achiever

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
43.7 V
Voc when cold
per panel
27.6 V
Vmp when hot
per panel
13
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–13
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–13
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–13
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window9–11

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V43.7 / 27.6 V✗ Not a match: module voltage below MPPT range1.17
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V43.7 / 27.6 V⚠ Works; below MPPT at peak heat0.57
Enphase IQ8M-72-2-US260–460 W60 V30–45 V43.7 / 27.6 V⚠ Works; below MPPT at peak heat1.37
Enphase IQ8A-72-2-US295–500 W60 V32–45 V43.7 / 27.6 V⚠ Works; below MPPT at peak heat1.28
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67674611,9336.08
Palmdale1,83581713,0656.69
Chula Vista1,69675512,0766.11
Huntington Beach1,64373111,6985.89
Riverside1,69675512,0766.21
Santa Clarita1,72476712,2756.28
779Jan780Feb1,000Mar1,105Apr1,091May1,160Jun1,222Jul1,236Aug1,081Sep953Oct820Nov709DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 445 W panels

CEC PV Module List (Oct 7, 2026) · datasheets · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, AWarrantyPVEL (product / brand)SoCal permits (series)
SEG Solar SEG-445-BMB-TB445 W≈20.6%−0.35841.2213.66—brand 5×—
Qcells Q.TRON BLK M-G2+ 445445 W≈22.8%−0.27640.1613.9825 / 25 yrbrand 11× (2016–2026)40
Silfab Solar SIL-440QD440 W≈22.6%−0.29438.9714.2525 / 30 yrbrand 7× (2017–2025)39
Hyundai Energy Solutions HiN-T445NF(BK)445 W≈22.9%−0.2983914.4625 / 30 yrbrand 5× (2017–2025)37
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

About SEG Solar

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · RETC PV Module Index · building permits

Other series by SoCal permits

SEG-xxx-BMD-HV · 20SEG-xxx-BTD-BG · 8SEG-xxx-BHC-BGSEG-xxx-BTA-BGSEG-xxx-BTA-HVSEG-xxx-BTB-BG

Questions & answers

How efficient is the SEG Solar SEG-445-BMB-TB?

Calculated from the panel area (2.16 m²): about 20.6% for the 445 W class. 445 W over 2.16 m² equals about 206 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 746 kWh per year per 445 W panel in Los Angeles and about 817 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.358 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 18.6% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–13 panels per string (Voc at 2 °C = 43.7 V, Vmp at 74 °C cell = 27.6 V). Final design must follow the inverter manual and NEC 690.7.

Has this panel been reliability-tested?

This exact series is not in published PVEL Top Performer tables; SEG Solar was named a Top Performer in 5 Scorecards (2022–2026).

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Qcells — manufacturer datasheet “Q.TRON BLK M-G2+ SERIES 415–440 Wp”.
  3. Silfab Solar — datasheet NTC SIL-420 QD CELL TECHNOLOGY.
  4. Hyundai Energy Solutions — datasheet [US] NF(BK)(HiN) Series (N TOPCon Bifacial) 435~445W.
  5. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2022–2026.
  6. RETC — PV Module Index reports 2023–2024.
  7. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  8. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  9. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  10. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  11. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).