Cali-GrafCali-Graf
Solar panelSEG Solar

SEG Solar SEG-360-BMB-HV {Blk}

120 half-cut cells. Power classes 320–460 W in the CEC list.

CEC listed · Jul 13, 2020UL 61730
Power class
  • Power (STC)360 WCEC nameplate
  • Efficiency≈19.8%calculated from area
  • %/°C Pmax−0.357CEC listing test
  • PTC / STC92.9%PTC 334 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 31 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
SEG-320-BMB-HV {Wht}320 W40.409.9334.009.42≈18.9%297 WJul 13, 2020
SEG-325-BMB-HV {Wht}325 W40.6010.0234.209.51≈19.2%301 WJul 13, 2020
SEG-330-BMB-HV {Blk}330 W40.8010.1134.409.60≈18.1%306 WFeb 1, 2022
SEG-330-BMB-HV {Wht}330 W40.8010.1134.409.60≈19.5%306 WJul 13, 2020
SEG-335-BMB-HV {Blk}335 W41.0010.2034.609.69≈18.4%310 WFeb 1, 2022
SEG-335-BMB-HV {Wht}335 W41.0010.2034.609.69≈19.8%311 WJul 13, 2020
SEG-340-BMB-HV {Blk}340 W41.1010.3234.709.80≈18.7%315 WFeb 1, 2022
SEG-340-BMB-HV {Wht}340 W41.1010.3234.709.80≈20.1%316 WJul 13, 2020
SEG-345-BMB-HV {Blk}345 W40.6010.8733.6010.27≈19.0%320 WFeb 1, 2022
SEG-345-BMB-HV {Wht}345 W40.6010.8733.6010.27≈18.4%320 WJul 13, 2020
SEG-350-BMB-HV {Blk}350 W40.8010.9833.8010.36≈19.2%325 WFeb 1, 2022
SEG-350-BMB-HV {Wht}350 W40.8010.9833.8010.36≈18.7%324 WJul 13, 2020
SEG-355-BMB-HV {Blk}355 W41.0011.0834.0010.45≈19.5%330 WFeb 1, 2022
SEG-355-BMB-HV {Wht}355 W41.0011.0834.0010.45≈19.0%329 WJul 13, 2020
SEG-360-BMB-HV {Blk}360 W41.2011.1634.2010.53≈19.8%334 WFeb 1, 2022
SEG-360-BMB-HV {Wht}360 W41.2011.1634.2010.53≈19.3%334 WJul 13, 2020
SEG-365-BMB-HV {Blk}365 W41.4011.2634.4010.62≈20.1%339 WFeb 1, 2022
SEG-365-BMB-HV {Wht}365 W41.4011.2634.4010.62≈19.5%339 WJul 13, 2020
SEG-370-BMB-HV {Blk}370 W41.6011.3434.6010.70≈20.3%344 WFeb 1, 2022
SEG-370-BMB-HV {Wht}370 W41.6011.3434.6010.70≈19.8%343 WJul 13, 2020
SEG-375-BMB-HV {Blk}375 W41.8011.4234.8010.79≈20.6%349 WFeb 1, 2022
SEG-415-BMB-HV415 W40.6213.0633.5512.39≈19.2%392 WApr 3, 2023
SEG-420-BMB-HV420 W40.7213.1633.6312.51≈19.4%397 WApr 3, 2023
SEG-425-BMB-HV425 W40.8213.2533.7712.61≈19.7%402 WApr 3, 2023
SEG-430-BMB-HV430 W40.9213.3633.8512.72≈19.9%406 WApr 3, 2023
SEG-435-BMB-HV435 W41.0113.4533.9812.82≈20.1%411 WApr 3, 2023
SEG-440-BMB-HV440 W41.1213.5634.0812.92≈20.4%416 WApr 3, 2023
SEG-445-BMB-HV445 W41.2213.6634.1813.03≈20.6%421 WApr 3, 2023
SEG-450-BMB-HV450 W41.3213.7634.2813.13≈20.8%426 WApr 3, 2023
SEG-455-BMB-HV455 W41.4213.8634.3913.24≈21.1%431 WApr 3, 2023
SEG-460-BMB-HV460 W41.5213.9634.4913.34≈21.3%436 WApr 3, 2023
≈ efficiency = Pmax ÷ CEC-listed area 1.69 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.357 %/°C
Voc coefficient β−0.283 %/°C
Isc coefficient α+0.053 %/°C
Operating cell temperatureNOCT 45.7 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
320 W238.3 W31.17 V × 7.64 A61.1 W95%
325 W242 W31.36 V × 7.72 A62 W95%
330 W247.9 W32.2 V × 7.7 A66.4 W101%
330 W245.7 W31.54 V × 7.79 A63 W95%
335 W251.7 W32.38 V × 7.77 A67.4 W101%
335 W249.4 W31.72 V × 7.86 A63.9 W95%
340 W255.3 W32.48 V × 7.86 A68.4 W101%
340 W253 W31.82 V × 7.95 A64.8 W95%
345 W259.1 W31.45 V × 8.24 A69.4 W101%
345 W254.3 W31.22 V × 8.15 A65.5 W95%
350 W262.9 W31.63 V × 8.31 A70.4 W101%
350 W258.1 W31.4 V × 8.22 A66.5 W95%
355 W266.8 W31.82 V × 8.38 A71.4 W101%
355 W261.9 W31.59 V × 8.29 A67.4 W95%
360 W270.4 W32.01 V × 8.45 A72.4 W101%
360 W265.4 W31.78 V × 8.35 A68.4 W95%
365 W274.3 W32.2 V × 8.52 A73.5 W101%
365 W269.3 W31.96 V × 8.42 A69.3 W95%
370 W278 W32.38 V × 8.58 A74.4 W101%
370 W272.9 W32.15 V × 8.49 A70.3 W95%
375 W281.9 W32.57 V × 8.66 A75.5 W101%
415 W308.9 W31.72 V × 9.74 A78.6 W95%
420 W312.6 W31.8 V × 9.83 A79.6 W95%
425 W316.4 W31.93 V × 9.91 A80.6 W95%
430 W319.9 W32.01 V × 10 A81.5 W95%
435 W323.7 W32.13 V × 10.07 A82.4 W95%
440 W327.2 W32.22 V × 10.15 A83.3 W95%
445 W330.9 W32.32 V × 10.24 A84.3 W95%
450 W334.4 W32.41 V × 10.32 A85.2 W95%
455 W338.3 W32.52 V × 10.4 A86.1 W95%
460 W341.9 W32.61 V × 10.48 A87.1 W95%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Independent reliability testing

Kiwa PVEL Scorecard · RETC PV Module Index
5
PVEL Scorecards
SEG Solar named Top Performer, 2022–2026
2
RETC PV Module Index
SEG Solar recognized 2023–2024
This exact series is not listed in published PVEL Top Performer tables. Results below are for the manufacturer.

RETC PV Module Index — SEG Solar

YearRecognition
2023High Achievement in Performance (LeTID RESISTANCE)
2024Test Category High Achiever

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
43.9 V
Voc when cold
per panel
27.3 V
Vmp when hot
per panel
13
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–13
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–13
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–13
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window9–11

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V43.9 / 27.3 V⚠ Works; below MPPT at peak heat1.24
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V43.9 / 27.3 V✗ Not a match: module voltage below MPPT range0.95
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V43.9 / 27.3 V⚠ Works; below MPPT at peak heat0.46
Enphase IQ8M-72-2-US260–460 W60 V30–45 V43.9 / 27.3 V⚠ Works; below MPPT at peak heat1.11
Enphase IQ8A-72-2-US295–500 W60 V32–45 V43.9 / 27.3 V⚠ Works; below MPPT at peak heat1.03
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67660311,4646.08
Palmdale1,83566112,5516.69
Chula Vista1,69661111,6016.11
Huntington Beach1,64359111,2385.89
Riverside1,69661111,6016.21
Santa Clarita1,72462111,7926.28
748Jan749Feb961Mar1,062Apr1,049May1,114Jun1,174Jul1,187Aug1,038Sep916Oct787Nov681DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 360 W panels

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
SEG Solar SEG-360-BMB-HV {Blk}360 W≈19.8%−0.35741.211.16brand 5×—
LONGi LR4-60HPB-360M360 W≈20.3%−0.33940.811.33product 2021, 2022193
REC Group REC360AA360 W≈21.4%−0.27944.110.23brand 9× (2016–2025)30
Trina Solar TSM-360DE06X.05(II)360 W≈19.8%−0.33944.810.3product 202223
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

About SEG Solar

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · RETC PV Module Index · building permits

Other series by SoCal permits

SEG-xxx-BMD-HV · 20SEG-xxx-BTD-BG · 8SEG-xxx-BHC-BGSEG-xxx-BTA-BGSEG-xxx-BTA-HVSEG-xxx-BTB-BG

Questions & answers

How efficient is the SEG Solar SEG-360-BMB-HV {Blk}?

Calculated from the panel area (1.87 m²): about 19.8% for the 360 W class. 360 W over 1.87 m² equals about 193 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 603 kWh per year per 360 W panel in Los Angeles and about 661 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.357 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 18.5% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–13 panels per string (Voc at 2 °C = 43.9 V, Vmp at 74 °C cell = 27.3 V). Final design must follow the inverter manual and NEC 690.7.

Has this panel been reliability-tested?

This exact series is not in published PVEL Top Performer tables; SEG Solar was named a Top Performer in 5 Scorecards (2022–2026).

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2022–2026.
  3. RETC — PV Module Index reports 2023–2024.
  4. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  5. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  6. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  7. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  8. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).