Cali-GrafCali-Graf
Solar panelSEG Solar

SEG Solar SEG-355-BMB-BG

120 half-cut cells, bifacial, glass (dual-glass module). Power classes 300–460 W in the CEC list.

CEC listed · May 21, 2020UL 61730Bifacial
Power class
  • Power (STC)355 WCEC nameplate
  • Efficiency≈19.0%calculated from area
  • %/°C Pmax−0.388CEC listing test
  • PTC / STC92.6%PTC 329 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 24 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
SEG-300-BMB-BG300 W39.609.5433.209.04≈17.4%278 WMay 21, 2020
SEG-305-BMB-BG305 W39.909.6133.509.11≈17.7%283 WMay 21, 2020
SEG-310-BMB-BG310 W40.209.6833.809.18≈18.0%287 WMay 21, 2020
SEG-315-BMB-BG315 W40.509.7534.109.24≈18.3%292 WMay 21, 2020
SEG-320-BMB-BG320 W40.709.8434.309.33≈18.6%297 WMay 21, 2020
SEG-325-BMB-BG325 W40.909.9334.509.43≈18.9%302 WMay 21, 2020
SEG-330-BMB-BG330 W41.1010.0234.709.52≈19.2%306 WMay 21, 2020
SEG-335-BMB-BG335 W41.3010.1034.909.60≈19.5%311 WMay 21, 2020
SEG-340-BMB-BG340 W41.4010.2335.009.72≈19.8%316 WMay 21, 2020
SEG-345-BMB-BG345 W40.6010.8733.6010.27≈18.4%319 WAug 21, 2020
SEG-350-BMB-BG350 W40.8011.0033.8010.36≈18.7%324 WAug 21, 2020
SEG-355-BMB-BG355 W41.0011.1034.0010.45≈19.0%329 WAug 21, 2020
SEG-360-BMB-BG360 W41.2011.2034.2010.53≈19.3%334 WAug 21, 2020
SEG-365-BMB-BG365 W41.4011.3034.4010.62≈19.5%338 WAug 21, 2020
SEG-415-BMB-BG415 W40.6213.0633.5512.39≈19.2%390 WApr 3, 2023
SEG-420-BMB-BG420 W40.7213.1633.6312.51≈19.4%395 WApr 3, 2023
SEG-425-BMB-BG425 W40.8213.2533.7712.61≈19.7%400 WApr 3, 2023
SEG-430-BMB-BG430 W40.9213.3633.8512.72≈19.9%404 WApr 3, 2023
SEG-435-BMB-BG435 W41.0113.4533.9812.82≈20.1%409 WApr 3, 2023
SEG-440-BMB-BG440 W41.1213.5634.0812.92≈20.4%414 WApr 3, 2023
SEG-445-BMB-BG445 W41.2213.6634.1813.03≈20.6%419 WApr 3, 2023
SEG-450-BMB-BG450 W41.3213.7634.2813.13≈20.8%424 WApr 3, 2023
SEG-455-BMB-BG455 W41.4213.8634.3913.24≈21.1%428 WApr 3, 2023
SEG-460-BMB-BG460 W41.5213.9634.4913.34≈21.3%433 WApr 3, 2023
≈ efficiency = Pmax ÷ CEC-listed area 1.72 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.388 %/°C
Voc coefficient β−0.300 %/°C
Isc coefficient α+0.035 %/°C
Operating cell temperatureNOCT 44.3 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
300 W217.8 W30.18 V × 7.22 A56.5 W94%
305 W221.4 W30.45 V × 7.27 A57.4 W94%
310 W225.1 W30.72 V × 7.33 A58.4 W94%
315 W228.6 W30.99 V × 7.38 A59.3 W94%
320 W232.2 W31.18 V × 7.45 A60.2 W94%
325 W236.1 W31.36 V × 7.53 A61.2 W94%
330 W239.7 W31.54 V × 7.6 A62.2 W94%
335 W243.1 W31.72 V × 7.66 A63 W94%
340 W246.9 W31.81 V × 7.76 A64 W94%
345 W309.1 W39.44 V × 7.84 A65.4 W95%
350 W260.9 W31.59 V × 8.26 A66.4 W95%
355 W260.9 W31.59 V × 8.26 A67.3 W95%
360 W264.8 W31.78 V × 8.33 A68.2 W95%
365 W268.4 W31.96 V × 8.4 A69.2 W95%
415 W304.3 W31.52 V × 9.65 A77.3 W93%
420 W308 W31.6 V × 9.75 A78.2 W93%
425 W311.8 W31.73 V × 9.83 A79.1 W93%
430 W315.2 W31.8 V × 9.91 A80 W93%
435 W318.9 W31.93 V × 9.99 A81 W93%
440 W322.3 W32.02 V × 10.07 A81.8 W93%
445 W326 W32.11 V × 10.15 A82.8 W93%
450 W329.5 W32.21 V × 10.23 A83.7 W93%
455 W333.3 W32.31 V × 10.32 A84.6 W93%
460 W336.8 W32.4 V × 10.39 A85.5 W93%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Independent reliability testing

Kiwa PVEL Scorecard · RETC PV Module Index
5
PVEL Scorecards
SEG Solar named Top Performer, 2022–2026
2
RETC PV Module Index
SEG Solar recognized 2023–2024
This exact series is not listed in published PVEL Top Performer tables. Results below are for the manufacturer.

RETC PV Module Index — SEG Solar

YearRecognition
2023High Achievement in Performance (LeTID RESISTANCE)
2024Test Category High Achiever

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
43.8 V
Voc when cold
per panel
27 V
Vmp when hot
per panel
13
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–13
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–13
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–13
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window9–11

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V43.8 / 27 V⚠ Works; below MPPT at peak heat1.22
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V43.8 / 27 V✗ Not a match: module voltage below MPPT range0.93
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V43.8 / 27 V⚠ Works; below MPPT at peak heat0.46
Enphase IQ8M-72-2-US260–460 W60 V30–45 V43.8 / 27 V⚠ Works; below MPPT at peak heat1.09
Enphase IQ8A-72-2-US295–500 W60 V32–45 V43.8 / 27 V⚠ Works; below MPPT at peak heat1.02
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67659511,9006.08
Palmdale1,83565113,0286.69
Chula Vista1,69660212,0426.11
Huntington Beach1,64358311,6655.89
Riverside1,69660212,0426.21
Santa Clarita1,72461212,2406.28
777Jan777Feb998Mar1,102Apr1,088May1,157Jun1,218Jul1,233Aug1,078Sep951Oct817Nov707DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 355 W panels

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
SEG Solar SEG-355-BMB-BG355 W≈19%−0.3884111.1brand 5×—
LONGi LR4-60HPB-355M355 W≈20.1%−0.33940.611.25product 2021, 2022193
REC Group REC355AA355 W≈21.1%−0.2794410.19brand 9× (2016–2025)30
Trina Solar TSM-355DE06X.05(II)355 W≈19.5%−0.33944.610.24product 202223
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

About SEG Solar

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · RETC PV Module Index · building permits

Other series by SoCal permits

SEG-xxx-BMD-HV · 20SEG-xxx-BTD-BG · 8SEG-xxx-BHC-BGSEG-xxx-BTA-BGSEG-xxx-BTA-HVSEG-xxx-BTB-BG

Questions & answers

How efficient is the SEG Solar SEG-355-BMB-BG?

Calculated from the panel area (1.87 m²): about 19% for the 355 W class. 355 W over 1.87 m² equals about 190 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 595 kWh per year per 355 W panel in Los Angeles and about 651 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.388 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 20.1% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–13 panels per string (Voc at 2 °C = 43.8 V, Vmp at 74 °C cell = 27 V). Final design must follow the inverter manual and NEC 690.7.

Is it bifacial?

Yes. Rear gain depends on mounting height and ground reflectance.

Has this panel been reliability-tested?

This exact series is not in published PVEL Top Performer tables; SEG Solar was named a Top Performer in 5 Scorecards (2022–2026).

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2022–2026.
  3. RETC — PV Module Index reports 2023–2024.
  4. NLR (formerly NREL) — System Advisor Model CEC module and inverter libraries (version 2026.7.3).
  5. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  6. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  7. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  8. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).