Solar panelSEG Solar

SEG Solar SEG-440-BMA-HV

144 half-cut cells. Power classes 385–550 W in the CEC list.

CEC listed · Jul 13, 2020UL 61730
Power class
  • Power (STC)440 WCEC nameplate
  • Efficiency≈19.8%calculated from area
  • %/°C Pmax−0.385CEC listing test
  • PTC / STC92.7%PTC 408 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 22 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
SEG-385-BMA-HV385 W48.309.8040.809.32≈19.1%357 WJul 13, 2020
SEG-390-BMA-HV390 W48.509.8741.009.40≈19.3%362 WJul 13, 2020
SEG-395-BMA-HV395 W48.709.9541.209.47≈19.6%367 WJul 13, 2020
SEG-400-BMA-HV400 W48.9010.0341.409.55≈19.8%372 WJul 13, 2020
SEG-405-BMA-HV405 W49.4010.1541.909.67≈20.0%376 WJul 13, 2020
SEG-410-BMA-HV410 W49.6010.2342.109.74≈20.3%381 WJul 13, 2020
SEG-420-BMA-HV420 W48.9010.9740.7010.32≈18.9%389 WJul 13, 2020
SEG-425-BMA-HV425 W49.2011.0440.9010.40≈19.1%394 WJul 13, 2020
SEG-430-BMA-HV430 W49.4011.1141.1010.47≈19.4%398 WJul 13, 2020
SEG-435-BMA-HV435 W49.6011.1841.3010.54≈19.6%403 WJul 13, 2020
SEG-440-BMA-HV440 W49.7011.2741.4010.63≈19.8%408 WJul 13, 2020
SEG-445-BMA-HV445 W49.9011.3441.6010.70≈20.0%413 WJul 13, 2020
SEG-505-BMA-HV505 W48.8113.1039.7412.72≈19.6%467 WFeb 1, 2022
SEG-510-BMA-HV510 W48.9013.2040.0012.76≈19.8%472 WFeb 1, 2022
SEG-515-BMA-HV515 W49.0113.3040.2612.80≈20.0%476 WFeb 1, 2022
SEG-520-BMA-HV520 W49.1013.4140.5212.84≈20.2%481 WFeb 1, 2022
SEG-525-BMA-HV525 W49.2013.5040.7812.88≈20.3%486 WFeb 1, 2022
SEG-530-BMA-HV530 W49.3313.6041.0312.92≈20.5%491 WFeb 1, 2022
SEG-535-BMA-HV535 W49.4013.7041.2912.96≈20.7%495 WFeb 1, 2022
SEG-540-BMA-HV540 W49.5013.8141.5513.00≈20.9%500 WFeb 1, 2022
SEG-545-BMA-HV545 W49.6013.9141.8113.04≈21.1%505 WFeb 1, 2022
SEG-550-BMA-HV550 W49.7014.0142.0713.08≈21.3%510 WFeb 1, 2022
≈ efficiency = Pmax ÷ CEC-listed area 2.02 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.385 %/°C
Voc coefficient β−0.302 %/°C
Isc coefficient α+0.033 %/°C
Operating cell temperatureNOCT 44.5 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
385 W292.1 W37.38 V × 7.81 A75.5 W98%
390 W296 W37.56 V × 7.88 A76.4 W98%
395 W299.7 W37.74 V × 7.94 A77.4 W98%
400 W303.6 W37.92 V × 8.01 A78.4 W98%
405 W309.7 W38.2 V × 8.11 A79.3 W98%
410 W313.4 W38.38 V × 8.17 A80.3 W98%
420 W317.2 W37.61 V × 8.43 A80.8 W96%
425 W321.2 W37.79 V × 8.5 A81.8 W96%
430 W325 W37.97 V × 8.56 A82.8 W96%
435 W328.7 W38.16 V × 8.61 A83.7 W96%
440 W332.3 W38.25 V × 8.69 A84.6 W96%
445 W336.1 W38.44 V × 8.75 A85.6 W96%
505 W380.6 W36.83 V × 10.34 A102.8 W102%
510 W384.3 W37.07 V × 10.37 A103.8 W102%
515 W388 W37.31 V × 10.4 A104.8 W102%
520 W391.7 W37.55 V × 10.43 A105.9 W102%
525 W395.5 W37.79 V × 10.46 A106.9 W102%
530 W399.1 W38.02 V × 10.5 A107.9 W102%
535 W402.9 W38.26 V × 10.53 A108.9 W102%
540 W406.7 W38.51 V × 10.56 A109.9 W102%
545 W410.5 W38.75 V × 10.6 A110.9 W102%
550 W414.3 W38.99 V × 10.63 A112 W102%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Independent reliability testing

Kiwa PVEL Scorecard · RETC PV Module Index
5
PVEL Scorecards
SEG Solar named Top Performer, 2022–2026
2
RETC PV Module Index
SEG Solar recognized 2023–2024
This exact series is not listed in published PVEL Top Performer tables. Results below are for the manufacturer.

RETC PV Module Index — SEG Solar

YearRecognition
2023High Achievement in Performance (LeTID RESISTANCE)
2024Test Category High Achiever

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
53.1 V
Voc when cold
per panel
32.9 V
Vmp when hot
per panel
11
Max panels / string
max DC 600 V
2
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet2–11
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–11
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–11
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window8–9

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V53.1 / 32.9 V✓ Within range1.52
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V53.1 / 32.9 V✗ Not a match: module voltage below MPPT range1.16
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V53.1 / 32.9 V✓ Within range0.56
Enphase IQ8M-72-2-US260–460 W60 V30–45 V53.1 / 32.9 V✓ Within range1.35
Enphase IQ8A-72-2-US295–500 W60 V32–45 V53.1 / 32.9 V✓ Within range1.26
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67673711,7996.08
Palmdale1,83580712,9186.69
Chula Vista1,69674611,9406.11
Huntington Beach1,64372311,5675.89
Riverside1,69674611,9406.21
Santa Clarita1,72475912,1376.28
770Jan771Feb989Mar1,093Apr1,079May1,147Jun1,208Jul1,222Aug1,069Sep943Oct810Nov701DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 440 W panels

CEC PV Module List (Oct 7, 2026) · datasheets · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, AWarrantyPVEL (product / brand)SoCal permits (series)
SEG Solar SEG-440-BMA-HV440 W≈19.8%−0.38549.711.27—brand 5×—
Qcells Q.TRON BLK M-G2+ 440440 W≥22.5%−0.27639.8813.925 / 25 yrbrand 11× (2016–2026)40
Silfab Solar SIL-440QD440 W≈22.6%−0.29438.9714.2525 / 30 yrbrand 7× (2017–2025)39
Hyundai Energy Solutions HiN-T440NF(BK)440 W≈22.7%−0.29838.814.3925 / 30 yrbrand 5× (2017–2025)37
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

About SEG Solar

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · RETC PV Module Index · building permits

Other series by SoCal permits

SEG-xxx-BMD-HV · 20SEG-xxx-BTD-BG · 8SEG-xxx-BHC-BGSEG-xxx-BTA-BGSEG-xxx-BTA-HVSEG-xxx-BTB-BG

Questions & answers

How efficient is the SEG Solar SEG-440-BMA-HV?

Calculated from the panel area (2.22 m²): about 19.8% for the 440 W class. 440 W over 2.22 m² equals about 198 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 737 kWh per year per 440 W panel in Los Angeles and about 807 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.385 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 20% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–11 panels per string (Voc at 2 °C = 53.1 V, Vmp at 74 °C cell = 32.9 V). Final design must follow the inverter manual and NEC 690.7.

Does it work with Enphase IQ8PLUS-72-2-US microinverters?

Voltage check against the Enphase datasheet: Voc when cold 53.1 V vs max input 60 V; Vmp when hot 32.9 V vs MPPT low 29 V; recommended module power 235–440 W. Confirm on the microinverter maker’s compatibility list.

Has this panel been reliability-tested?

This exact series is not in published PVEL Top Performer tables; SEG Solar was named a Top Performer in 5 Scorecards (2022–2026).

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Qcells — manufacturer datasheet “Q.TRON BLK M-G2+ SERIES 415–440 Wp”.
  3. Silfab Solar — datasheet NTC SIL-420 QD CELL TECHNOLOGY.
  4. Hyundai Energy Solutions — datasheet [US] NF(BK)(HiN) Series (N TOPCon Bifacial) 435~445W.
  5. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2022–2026.
  6. RETC — PV Module Index reports 2023–2024.
  7. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  8. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  9. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  10. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  11. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).