Cali-GrafCali-Graf
Solar panelSEG Solar

SEG Solar SEG-320-6MB-HV

60 cells. Power classes 315–330 W in the CEC list.

CEC listed · Aug 21, 2020UL 61730
Power class
  • Power (STC)320 WCEC nameplate
  • Efficiency≈19.2%calculated from area
  • %/°C Pmax−0.395CEC listing test
  • PTC / STC92.6%PTC 296 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 4 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
SEG-315-6MB-HV315 W40.909.8932.809.61≈18.9%292 WAug 21, 2020
SEG-320-6MB-HV320 W41.109.9833.009.70≈19.2%296 WAug 21, 2020
SEG-325-6MB-HV325 W41.3010.0733.209.79≈19.5%301 WAug 21, 2020
SEG-330-6MB-HV330 W41.6010.1433.509.86≈19.8%306 WAug 21, 2020
≈ efficiency = Pmax ÷ CEC-listed area 1.67 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.395 %/°C
Voc coefficient β−0.306 %/°C
Isc coefficient α+0.033 %/°C
Operating cell temperatureNOCT 44.2 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
315 W238.4 W30.24 V × 7.89 A62.8 W100%
320 W242.1 W30.42 V × 7.96 A63.8 W100%
325 W245.9 W30.6 V × 8.03 A64.8 W100%
330 W249.9 W30.88 V × 8.09 A65.8 W100%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Independent reliability testing

Kiwa PVEL Scorecard · RETC PV Module Index
5
PVEL Scorecards
SEG Solar named Top Performer, 2022–2026
2
RETC PV Module Index
SEG Solar recognized 2023–2024
This exact series is not listed in published PVEL Top Performer tables. Results below are for the manufacturer.

RETC PV Module Index — SEG Solar

YearRecognition
2023High Achievement in Performance (LeTID RESISTANCE)
2024Test Category High Achiever

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
44 V
Voc when cold
per panel
26.1 V
Vmp when hot
per panel
13
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–13
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet4–13
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–13
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window9–11

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V44 / 26.1 V⚠ Works; below MPPT at peak heat1.1
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V44 / 26.1 V✗ Not a match: module voltage below MPPT range0.84
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V44 / 26.1 V⚠ Works; below MPPT at peak heat0.41
Enphase IQ8M-72-2-US260–460 W60 V30–45 V44 / 26.1 V⚠ Works; below MPPT at peak heat0.98
Enphase IQ8A-72-2-US295–500 W60 V32–45 V44 / 26.1 V⚠ Works; below MPPT at peak heat0.92
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67653611,7996.08
Palmdale1,83558712,9186.69
Chula Vista1,69654311,9406.11
Huntington Beach1,64352611,5675.89
Riverside1,69654311,9406.21
Santa Clarita1,72455212,1376.28
770Jan771Feb989Mar1,093Apr1,079May1,147Jun1,208Jul1,222Aug1,069Sep943Oct810Nov701DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 320 W panels

CEC PV Module List (Oct 7, 2026) · datasheets · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
SEG Solar SEG-320-6MB-HV320 W≈19.2%−0.39541.19.98brand 5×—
JinkoSolar JKM320M-60HBL320 W≈19%−0.40740.910.15brand 12× (2014–2026)45
LG Electronics LG320N1C-N5320 W≈18.5%−0.34240.810.53product 20215
REC Group REC320NP320 W≈19.8%−0.35140.810.18brand 9× (2016–2025)4
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

About SEG Solar

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · RETC PV Module Index · building permits

Other series by SoCal permits

SEG-xxx-BMD-HV · 20SEG-xxx-BTD-BG · 8SEG-xxx-BHC-BGSEG-xxx-BTA-BGSEG-xxx-BTA-HVSEG-xxx-BTB-BG

Questions & answers

How efficient is the SEG Solar SEG-320-6MB-HV?

Calculated from the panel area (1.67 m²): about 19.2% for the 320 W class. 320 W over 1.67 m² equals about 192 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 536 kWh per year per 320 W panel in Los Angeles and about 587 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.395 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 20.5% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–13 panels per string (Voc at 2 °C = 44 V, Vmp at 74 °C cell = 26.1 V). Final design must follow the inverter manual and NEC 690.7.

Has this panel been reliability-tested?

This exact series is not in published PVEL Top Performer tables; SEG Solar was named a Top Performer in 5 Scorecards (2022–2026).

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. JinkoSolar — datasheet THE MOST DEPENDABLE SOLAR BRAND.
  3. JinkoSolar — manufacturer datasheet “Eagle HC 60M G2 315-335 Watt MONO PERC HALF CELL MODULE”.
  4. LG Electronics — datasheet Specification Sheet.
  5. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2022–2026.
  6. RETC — PV Module Index reports 2023–2024.
  7. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  8. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  9. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  10. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  11. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).