108 half-cut cells. Power classes 385–405 W in the CEC list.
| Model | Pmax | Voc, V | Isc, A | Vmp, V | Imp, A | Efficiency | PTC | CEC listed |
|---|---|---|---|---|---|---|---|---|
| SGE385-108MHCB | 385 W | 36.65 | 13.23 | 30.56 | 12.61 | ≈19.8% | 351 W | Apr 3, 2023 |
| SGE390-108MHCB | 390 W | 36.91 | 13.30 | 30.76 | 12.76 | ≈20.1% | 356 W | Apr 3, 2023 |
| SGE395-108MHCB | 395 W | 37.18 | 13.39 | 30.98 | 12.75 | ≈20.4% | 360 W | Apr 3, 2023 |
| SGE400-108MHCB | 400 W | 37.42 | 13.47 | 31.17 | 12.83 | ≈20.6% | 365 W | Apr 3, 2023 |
| SGE405-108MHCB | 405 W | 37.67 | 13.55 | 31.40 | 12.90 | ≈20.9% | 370 W | Apr 3, 2023 |
| CEC listing test | |
|---|---|
| Pmax coefficient γ | −0.423 %/°C |
| Isc coefficient α | +0.002 %/°C |
| Operating cell temperature | NOCT 46.6 °C |
| Class | Pmax at NOCT | Vmp × Imp at NOCT | Pmax at 200 W/m² | Low-light efficiency vs STC |
|---|---|---|---|---|
| 385 W | 286.1 W | 29.31 V × 9.76 A | 74 W | 96% |
| 390 W | 291.4 W | 29.51 V × 9.88 A | 75.4 W | 97% |
| 395 W | 293.3 W | 29.72 V × 9.87 A | 75.9 W | 96% |
| 400 W | 296.9 W | 29.9 V × 9.93 A | 76.8 W | 96% |
| 405 W | 300.7 W | 30.12 V × 9.98 A | 77.8 W | 96% |
| City | kWh / kW / yr | kWh / panel / yr | kWh / system / yr | Sun, kWh/m²/day |
|---|---|---|---|---|
| Los Angeles | 1,676 | 662 | 11,916 | 6.08 |
| Palmdale | 1,835 | 725 | 13,047 | 6.69 |
| Chula Vista | 1,696 | 670 | 12,059 | 6.11 |
| Huntington Beach | 1,643 | 649 | 11,682 | 5.89 |
| Riverside | 1,696 | 670 | 12,059 | 6.21 |
| Santa Clarita | 1,724 | 681 | 12,258 | 6.28 |
| Panel | Pmax | Efficiency | γ Pmax (CEC) | Voc, V | Isc, A | PVEL (product / brand) | SoCal permits (series) |
|---|---|---|---|---|---|---|---|
| Saatvik Green Energy SGE395-108MHCB | 395 W | ≈20.4% | −0.423 | 37.18 | 13.39 | brand 1× | — |
| Qcells Q.PEAK DUO BLK ML-G10+ 395 | 395 W | ≥20.1% | −0.362 | 45.27 | 11.1 | product 2022, 2023 | 221 |
| JA Solar JAM54S31-395/MR | 395 W | ≈20.8% | −0.329 | 36.98 | 13.7 | product 2023, 2024 | 152 |
| REC Group REC395AA Pure | 395 W | ≈22% | −0.256 | 48.7 | 10.2 | brand 9× (2016–2025) | 66 |
Calculated from the panel area (1.94 m²): about 20.4% for the 395 W class. 395 W over 1.94 m² equals about 204 W per square meter.
PVWatts v8 with typical-year weather gives about 662 kWh per year per 395 W panel in Los Angeles and about 725 kWh in Palmdale (20° roof, facing south, 14% system losses).
With γ = −0.423 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 21.9% below the STC rating.
This exact series is not in published PVEL Top Performer tables; Saatvik Green Energy was named a Top Performer in 1 Scorecard (2024).