Cali-GrafCali-Graf
Solar panelS-Energy

S-Energy SL65-54TEP-425V

108 half-cut cells, N-type TOPCon, bifacial, semi-toughened glass, 2.0mm. Power classes 405–440 W in the CEC list; datasheet covers 415–446 W.

CEC listed · Jul 22, 2024UL 61730Bifacial · 80%N-type TOPCon
Power class
  • Power (STC)425 Wtolerance +5 / −0 W
  • Efficiency≥21.8%datasheet minimum
  • %/°C Pmax−0.30CEC test: −0.296
  • PTC / STC94.3%PTC 401 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · S-Energy datasheet · 8 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
SL65-54TEP-405V405 W37.6813.8331.0213.07≈20.7%381 WJul 22, 2024
SL65-54TEP-410V410 W37.7513.9131.1413.17≈21.0%386 WJul 22, 2024
SL65-54TEP-415V415 W37.9213.9931.3313.24≥21.2%391 WJul 22, 2024
SL65-54TEP-420V420 W38.1114.0731.5213.32≥21.5%396 WJul 22, 2024
SL65-54TEP-425V425 W38.4014.1631.7213.40≥21.8%401 WJul 22, 2024
SL65-54TEP-430V430 W38.5014.2431.8913.50≥22.0%406 WJul 22, 2024
SL65-54TEP-435V435 W38.6314.3032.0613.57≈22.3%410 WJul 22, 2024
SL65-54TEP-440V440 W38.7914.3732.2613.64≈22.5%415 WJul 22, 2024
≈ efficiency = Pmax ÷ panel area 1.953 m² (datasheet size) for classes outside the datasheet.

Build & dimensions

S-Energy datasheet · Cali-Graf calculation · CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

S-Energy datasheet · CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
DatasheetCEC listing test
Pmax coefficient γ−0.30 %/°C−0.296 %/°C
Voc coefficient β−0.26 %/°C−0.241 %/°C
Isc coefficient α+0.05 %/°C+0.040 %/°C
Vmp coefficient≈ −0.35 %/°C—
Operating cell temperatureNMOT 45 ± 2 °CNOCT 45.7 °C
Vmp coefficient ≈ γ − α (datasheet); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
405 W304.8 W30.6 V × 9.96 A77.3 W95%
410 W308.3 W30.72 V × 10.04 A78.2 W95%
415 W311.8 W30.91 V × 10.09 A79.1 W95%
420 W315.6 W31.1 V × 10.15 A80.1 W95%
425 W319.5 W31.29 V × 10.21 A81.1 W95%
430 W323.7 W31.46 V × 10.29 A82.1 W95%
435 W327.1 W31.63 V × 10.34 A83 W95%
440 W330.8 W31.83 V × 10.39 A83.9 W95%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Electrical & strength ratings

S-Energy datasheet
Packaging: 35 per pallet · 210 per container

Bifacial performance

NLR SAM module library · S-Energy datasheet
Rear gain depends on mounting height and ground reflectance; flush roof mounts receive little rear light.

Certifications

CEC PV Module List (Oct 7, 2026) · S-Energy datasheet
UL 61730IEC 61215ISO 14001ISO 45001ISO 9001

Inverter compatibility & string sizing

S-Energy datasheet · Cali-Graf calculation · NLR PVWatts v8 · CEC PV Module List (Oct 7, 2026) · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
40.7 V
Voc when cold
per panel
26.3 V
Vmp when hot
per panel
14
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–14
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet4–14
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–14
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window9–12

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V40.7 / 26.3 V⚠ Works; below MPPT at peak heat1.47
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V40.7 / 26.3 V✗ Not a match: module voltage below MPPT range1.12
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V40.7 / 26.3 V⚠ Works; below MPPT at peak heat0.54
Enphase IQ8M-72-2-US260–460 W60 V30–45 V40.7 / 26.3 V⚠ Works; below MPPT at peak heat1.31
Enphase IQ8A-72-2-US295–500 W60 V32–45 V40.7 / 26.3 V✗ Not a match: module voltage below MPPT range1.22
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67671211,3976.08
Palmdale1,83578012,4786.69
Chula Vista1,69672111,5336.11
Huntington Beach1,64369811,1725.89
Riverside1,69672111,5336.21
Santa Clarita1,72473311,7236.28
744Jan745Feb955Mar1,055Apr1,042May1,108Jun1,167Jul1,180Aug1,032Sep911Oct783Nov677DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 425 W panels

CEC PV Module List (Oct 7, 2026) · datasheets · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, ASizeWarrantyPVEL (product / brand)SoCal permits (series)
S-Energy SL65-54TEP-425V425 W≥21.8%−0.29638.414.1667.8 × 44.6 in———
Canadian Solar CS3N-425MS425 W≥20.9%−0.33245.511.8—25 yrproduct 202346
Qcells Q.TRON BLK M-G2+ 425425 W≥21.8%−0.27639.0313.6667.8 × 44.6 in25 / 25 yrbrand 11× (2016–2026)40
Silfab Solar SIL-425QD425 W≈21.8%−0.29438.8813.6867.8 × 44.6 in25 / 30 yrbrand 7× (2017–2025)39
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the S-Energy SL65-54TEP-425V?

The S-Energy datasheet guarantees at least 21.8% module efficiency for the 425 W class (up to 22% for 430 W). 425 W over 1.95 m² equals about 218 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 712 kWh per year per 425 W panel in Los Angeles and about 780 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.30 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 15.5% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–14 panels per string (Voc at 2 °C = 40.7 V, Vmp at 74 °C cell = 26.3 V). Final design must follow the inverter manual and NEC 690.7.

How big and heavy is it?

67.8 × 44.6 × 1.18 in (1,722 × 1,134 × 30 mm), 54.5 lb (24.7 kg).

Is it bifacial?

Yes, bifaciality 80%. Rear gain depends on mounting height and ground reflectance.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. S-Energy — manufacturer datasheet “2024 EN Ver. 1.0 SL65-54TEP N Type TOP Con Series”.
  3. Canadian Solar — manufacturer datasheet “HiKu Mono PERC CS3N-400|405|410|415|420|425MS MORE POWER”.
  4. Qcells — manufacturer datasheet “Q.TRON BLK M-G2+ SERIES 415–440 Wp”.
  5. Silfab Solar — datasheet NTC SIL-420 QD CELL TECHNOLOGY.
  6. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
  7. NLR (formerly NREL) — System Advisor Model CEC module and inverter libraries (version 2026.7.3).
  8. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  9. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  10. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  11. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).