Roofit Solar Energy Velario 115/3x8/002

24 cells, BIPV module. 115 W in the CEC list.

CEC listed · Jul 13, 2026UL 61730Building-integrated (BIPV)
  • Power (STC)115 WCEC nameplate
  • Efficiency≈15.5%calculated from area
  • %/°C Pmax−0.363CEC listing test
  • PTC / STC93.5%PTC 108 W (CEC)

Electrical ratings (STC)

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
Velario 115/3x8/002115 W16.309.3513.208.70≈15.5%108 WJul 13, 2026
≈ efficiency = Pmax ÷ CEC-listed area 0.74 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.363 %/°C
Voc coefficient β−0.278 %/°C
Isc coefficient α+0.043 %/°C
Operating cell temperatureNOCT 42.1 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
115 W77.9 W11.59 V × 6.72 A21.3 W92%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8
17.3 V
Voc when cold
per panel
10.6 V
Vmp when hot
per panel
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.
Integrated roof products are wired per the manufacturer’s system design.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,6761935,7826.08
Palmdale1,8352116,3316.69
Chula Vista1,6961955,8516.11
Huntington Beach1,6431895,6685.89
Riverside1,6961955,8516.21
Santa Clarita1,7241985,9486.28
377Jan378Feb485Mar535Apr529May562Jun592Jul599Aug524Sep462Oct397Nov344DeckWh per month · Los Angeles
PVWatts models a standard roof-mounted module; integrated roof products are not modeled separately.
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Questions & answers

How efficient is the Roofit Solar Energy Velario 115/3x8/002?

Calculated from the panel area (0.74 m²): about 15.5% for the 115 W class. 115 W over 0.74 m² equals about 155 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 193 kWh per year per 115 W panel in Los Angeles and about 211 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.363 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 18.8% below the STC rating.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List (snapshot Oct 7, 2026).
  2. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  3. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).