Solar panelRNG International

RNG International RSP240D-BK-64

64 cells. Power classes 235–245 W in the CEC list.

CEC listed · May 11, 2023UL 61730
Power class
  • Power (STC)240 WCEC nameplate
  • Efficiency≈20.5%calculated from area
  • %/°C Pmax−0.328CEC listing test
  • PTC / STC94.3%PTC 226 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 3 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
RSP235D-BK-64235 W21.8713.5718.5112.70≈20.1%222 WMay 11, 2023
RSP240D-BK-64240 W22.1013.6418.7712.79≈20.5%226 WMay 11, 2023
RSP245D-BK-64245 W22.2813.7118.9512.93≈20.9%231 WMay 11, 2023
≈ efficiency = Pmax ÷ CEC-listed area 1.17 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.328 %/°C
Voc coefficient β−0.289 %/°C
Isc coefficient α+0.035 %/°C
Operating cell temperatureNOCT 43.2 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
235 W176.7 W17.39 V × 10.16 A45 W96%
240 W180.5 W17.63 V × 10.23 A45.9 W96%
245 W184.2 W17.8 V × 10.35 A46.9 W96%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
23.6 V
Voc when cold
per panel
15.4 V
Vmp when hot
per panel
25
Max panels / string
max DC 600 V
4
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet4–25
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet6–25
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet7–25
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window16–21

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V23.6 / 15.4 V✗ Not a match: module voltage below MPPT range0.83
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67640211,6656.08
Palmdale1,83544012,7726.69
Chula Vista1,69640711,8046.11
Huntington Beach1,64339411,4355.89
Riverside1,69640711,8046.21
Santa Clarita1,72441411,9996.28
761Jan762Feb978Mar1,080Apr1,067May1,134Jun1,194Jul1,208Aug1,057Sep932Oct801Nov693DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Questions & answers

How efficient is the RNG International RSP240D-BK-64?

Calculated from the panel area (1.17 m²): about 20.5% for the 240 W class. 240 W over 1.17 m² equals about 205 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 402 kWh per year per 240 W panel in Los Angeles and about 440 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.328 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 17% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 4–25 panels per string (Voc at 2 °C = 23.6 V, Vmp at 74 °C cell = 15.4 V). Final design must follow the inverter manual and NEC 690.7.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  3. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  4. Inverter datasheets — Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  5. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).