Cali-GrafCali-Graf
Solar panelRNG International

RNG International RSP455D-BK-120

120 cells. Power classes 445–465 W in the CEC list.

CEC listed · May 11, 2023UL 61730
Power class
  • Power (STC)455 WCEC nameplate
  • Efficiency≈21.2%calculated from area
  • %/°C Pmax−0.328CEC listing test
  • PTC / STC94.4%PTC 429 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 5 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
RSP445D-BK-120445 W41.1013.8234.4812.91≈20.7%420 WMay 11, 2023
RSP450D-BK-120450 W41.2513.8934.6712.98≈20.9%424 WMay 11, 2023
RSP455D-BK-120455 W41.4013.9734.8713.05≈21.2%429 WMay 11, 2023
RSP460D-BK-120460 W41.5814.0735.0813.12≈21.4%434 WMay 11, 2023
RSP465D-BK-120465 W41.7114.1535.1313.24≈21.6%439 WMay 11, 2023
≈ efficiency = Pmax ÷ CEC-listed area 2.15 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.328 %/°C
Voc coefficient β−0.289 %/°C
Isc coefficient α+0.035 %/°C
Operating cell temperatureNOCT 43.2 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
445 W329.9 W31.47 V × 10.48 A85.5 W96%
450 W333.5 W31.64 V × 10.54 A86.5 W96%
455 W337.3 W31.82 V × 10.6 A87.4 W96%
460 W341.1 W32.02 V × 10.65 A88.4 W96%
465 W344.7 W32.06 V × 10.75 A89.4 W96%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
44.1 V
Voc when cold
per panel
28.7 V
Vmp when hot
per panel
13
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–13
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–13
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–13
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window9–11

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V44.1 / 28.7 V✗ Not a match: module voltage below MPPT range1.2
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V44.1 / 28.7 V✓ Within range0.58
Enphase IQ8M-72-2-US260–460 W60 V30–45 V44.1 / 28.7 V⚠ Works; below MPPT at peak heat1.4
Enphase IQ8A-72-2-US295–500 W60 V32–45 V44.1 / 28.7 V⚠ Works; below MPPT at peak heat1.3
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67676311,4396.08
Palmdale1,83583512,5246.69
Chula Vista1,69677211,5756.11
Huntington Beach1,64374811,2135.89
Riverside1,69677211,5756.21
Santa Clarita1,72478411,7666.28
747Jan747Feb959Mar1,059Apr1,046May1,112Jun1,171Jul1,185Aug1,036Sep914Oct786Nov680DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 455 W panels

CEC PV Module List (Oct 7, 2026) · datasheets · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, ASoCal permits (series)
RNG International RSP455D-BK-120455 W≈21.2%−0.32841.413.97—
Hyundai Energy Solutions HiN-T450NF(BK)450 W≈23.2%−0.29839.214.5337
REC Group REC455AA Pure-RX455 W≈22.5%−0.24865.68.8433
Aptos Solar DNA-120-MF10-455W455 W≈21%−0.36341.513.9322
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the RNG International RSP455D-BK-120?

Calculated from the panel area (2.15 m²): about 21.2% for the 455 W class. 455 W over 2.15 m² equals about 212 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 763 kWh per year per 455 W panel in Los Angeles and about 835 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.328 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 17% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–13 panels per string (Voc at 2 °C = 44.1 V, Vmp at 74 °C cell = 28.7 V). Final design must follow the inverter manual and NEC 690.7.

Does it work with APsystems (Alt Power System) DS3-L microinverters?

Voltage check against the APsystems (Alt Power System) datasheet: Voc when cold 44.1 V vs max input 60 V; Vmp when hot 28.7 V vs MPPT low 28 V; recommended module power 265–570 W. Confirm on the microinverter maker’s compatibility list.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Hyundai Energy Solutions — datasheet [US] NF(BK)(HiN) Series (N TOPCon Bifacial) 435~445W.
  3. Aptos Solar — datasheet Legacy Products.
  4. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
  5. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  6. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  7. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  8. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  9. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).