Cali-GrafCali-Graf
Solar panelRisen Energy

Risen Energy RSM144-7-440BMDG

144 half-cut cells, bifacial, glass (dual-glass module). Power classes 425–455 W in the CEC list.

CEC listed · May 21, 2021UL 61730BifacialPVEL Top Performer 2021, 2022
Power class
  • Power (STC)440 WCEC nameplate
  • Efficiency≈19.7%calculated from area
  • %/°C Pmax−0.337CEC listing test
  • PTC / STC93.4%PTC 411 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 7 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
RSM144-7-425BMDG425 W49.2011.0040.9010.40≈19.1%396 WMay 21, 2021
RSM144-7-430BMDG430 W49.3011.1040.9610.50≈19.3%401 WMay 21, 2021
RSM144-7-435BMDG435 W49.4011.2041.0510.60≈19.5%406 WMay 21, 2021
RSM144-7-440BMDG440 W49.5011.3041.1310.70≈19.7%411 WMay 21, 2021
RSM144-7-445BMDG445 W49.6011.4041.2510.80≈20.0%416 WMay 21, 2021
RSM144-7-450BMDG450 W49.7011.5041.3010.90≈20.2%420 WMay 21, 2021
RSM144-7-455BMDG455 W49.8011.6041.4011.00≈20.4%425 WMay 21, 2021
≈ efficiency = Pmax ÷ CEC-listed area 2.23 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.337 %/°C
Voc coefficient β−0.267 %/°C
Isc coefficient α+0.038 %/°C
Operating cell temperatureNOCT 45.3 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
425 W327.4 W38.07 V × 8.6 A85.5 W101%
430 W331.1 W38.12 V × 8.68 A86.5 W101%
435 W335 W38.21 V × 8.77 A87.5 W101%
440 W338.8 W38.28 V × 8.85 A88.5 W101%
445 W342.9 W38.39 V × 8.93 A89.6 W101%
450 W346.5 W38.44 V × 9.02 A90.5 W101%
455 W350.6 W38.53 V × 9.1 A91.6 W101%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Independent reliability testing

Kiwa PVEL Scorecard · RETC PV Module Index
2021, 2022
PVEL Top Performer
this series
5
Tests passed as Top Performer
DH, LID+LETID, PAN, PID, TC
5
PVEL Scorecards
Risen Energy named Top Performer, 2021–2025
1
RETC PV Module Index
Risen Energy, 2025

PVEL Top Performer tests

YearProductTests
2022RSM144-7-xxxBMDGDHLID+LETIDPANPIDTC
2021RSM144‐7‐xxxBMDGLID+LETIDPID

Tested bill of materials

Details describe the tested sample, not every module of the series.

RETC PV Module Index — Risen Energy

YearRecognition
2025Test Category High Achiever

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
52.5 V
Voc when cold
per panel
33.6 V
Vmp when hot
per panel
11
Max panels / string
max DC 600 V
2
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet2–11
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–11
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet3–11
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window7–9

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V52.5 / 33.6 V✓ Within range1.52
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V52.5 / 33.6 V✗ Not a match: module voltage below MPPT range1.16
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V52.5 / 33.6 V✓ Within range0.56
Enphase IQ8M-72-2-US260–460 W60 V30–45 V52.5 / 33.6 V✓ Within range1.35
Enphase IQ8A-72-2-US295–500 W60 V32–45 V52.5 / 33.6 V✓ Within range1.26
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67673711,7996.08
Palmdale1,83580712,9186.69
Chula Vista1,69674611,9406.11
Huntington Beach1,64372311,5675.89
Riverside1,69674611,9406.21
Santa Clarita1,72475912,1376.28
770Jan771Feb989Mar1,093Apr1,079May1,147Jun1,208Jul1,222Aug1,069Sep943Oct810Nov701DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 440 W panels

CEC PV Module List (Oct 7, 2026) · datasheets · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, AWarrantyPVEL (product / brand)SoCal permits (series)
Risen Energy RSM144-7-440BMDG440 W≈19.7%−0.33749.511.3—product 2021, 2022—
Qcells Q.TRON BLK M-G2+ 440440 W≥22.5%−0.27639.8813.925 / 25 yrbrand 11× (2016–2026)40
Silfab Solar SIL-440QD440 W≈22.6%−0.29438.9714.2525 / 30 yrbrand 7× (2017–2025)39
Hyundai Energy Solutions HiN-T440NF(BK)440 W≈22.7%−0.29838.814.3925 / 30 yrbrand 5× (2017–2025)37
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

About Risen Energy

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · RETC PV Module Index

Other series by SoCal permits

RSM132-8-xxxBHDGRSM110-8-xxxBHDGRSM132-8-xxxBMDGRSM132-8-xxxMRSM110-8-xxxBMDGRSM110-8-xxxM

Questions & answers

How efficient is the Risen Energy RSM144-7-440BMDG?

Calculated from the panel area (2.23 m²): about 19.7% for the 440 W class. 440 W over 2.23 m² equals about 197 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 737 kWh per year per 440 W panel in Los Angeles and about 807 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.337 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 17.5% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–11 panels per string (Voc at 2 °C = 52.5 V, Vmp at 74 °C cell = 33.6 V). Final design must follow the inverter manual and NEC 690.7.

Does it work with Enphase IQ8PLUS-72-2-US microinverters?

Voltage check against the Enphase datasheet: Voc when cold 52.5 V vs max input 60 V; Vmp when hot 33.6 V vs MPPT low 29 V; recommended module power 235–440 W. Confirm on the microinverter maker’s compatibility list.

Is it bifacial?

Yes. Rear gain depends on mounting height and ground reflectance.

Has this panel been reliability-tested?

RSM144-7-xxxBMDG was a PVEL Top Performer in 2022 (DH, LID+LETID, PAN, PID, TC).

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Qcells — manufacturer datasheet “Q.TRON BLK M-G2+ SERIES 415–440 Wp”.
  3. Silfab Solar — datasheet NTC SIL-420 QD CELL TECHNOLOGY.
  4. Hyundai Energy Solutions — datasheet [US] NF(BK)(HiN) Series (N TOPCon Bifacial) 435~445W.
  5. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2021–2025.
  6. RETC — PV Module Index report.
  7. NLR (formerly NREL) — System Advisor Model CEC module and inverter libraries (version 2026.7.3).
  8. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  9. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  10. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  11. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).