Cali-GrafCali-Graf
Solar panelRisen Energy

Risen Energy RSM132-8-690BHDG

132 cells, bifacial, glass (dual-glass module). Power classes 650–730 W in the CEC list.

CEC listed · May 22, 2023UL 61730BifacialPVEL Top Performer 2025
Power class
  • Power (STC)690 WCEC nameplate
  • Efficiency≈22.2%calculated from area
  • %/°C Pmax−0.266CEC listing test
  • PTC / STC95.3%PTC 658 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 17 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
RSM132-8-650BHDG650 W48.9316.9741.0315.86≈20.9%619 WMay 22, 2023
RSM132-8-655BHDG655 W49.0217.0641.1015.96≈21.1%624 WMay 22, 2023
RSM132-8-660BHDG660 W49.1117.1441.1816.05≈21.2%629 WMay 22, 2023
RSM132-8-665BHDG665 W49.2017.2241.2516.14≈21.4%634 WMay 22, 2023
RSM132-8-670BHDG670 W49.2917.3141.3316.23≈21.5%638 WMay 22, 2023
RSM132-8-675BHDG675 W49.3817.4041.4116.32≈21.7%643 WMay 22, 2023
RSM132-8-680BHDG680 W49.4717.4841.4816.41≈21.9%648 WMay 22, 2023
RSM132-8-685BHDG685 W49.5617.5641.5616.50≈22.0%653 WMay 22, 2023
RSM132-8-690BHDG690 W49.6517.6641.6316.60≈22.2%658 WMay 22, 2023
RSM132-8-695BHDG695 W49.7417.7441.7116.68≈22.3%663 WMay 22, 2023
RSM132-8-700BHDG700 W49.8317.8241.7816.77≈22.5%664 WMay 22, 2023
RSM132-8-705BHDG705 W49.9217.9141.8616.86≈22.7%668 WMay 22, 2023
RSM132-8-710BHDG710 W50.0118.0041.9316.95≈22.8%673 WMay 22, 2023
RSM132-8-715BHDG715 W50.0918.0842.0117.03≈23.0%678 WMay 22, 2023
RSM132-8-720BHDG720 W50.1818.1942.0817.13≈23.2%683 WFeb 11, 2025
RSM132-8-725BHDG725 W50.2618.2942.1417.23≈23.3%688 WFeb 11, 2025
RSM132-8-730BHDG730 W50.3318.3842.2017.32≈23.5%693 WFeb 11, 2025
≈ efficiency = Pmax ÷ CEC-listed area 3.11 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.266 %/°C
Voc coefficient β−0.224 %/°C
Isc coefficient α+0.013 %/°C
Operating cell temperatureNOCT 43.9 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
650 W486.4 W39.14 V × 12.43 A125 W96%
655 W490.3 W39.21 V × 12.5 A126 W96%
660 W494 W39.29 V × 12.57 A127 W96%
665 W497.6 W39.35 V × 12.64 A127.9 W96%
670 W501.4 W39.43 V × 12.72 A128.9 W96%
675 W505.1 W39.51 V × 12.79 A129.8 W96%
680 W508.8 W39.57 V × 12.86 A130.8 W96%
685 W512.5 W39.65 V × 12.93 A131.7 W96%
690 W516.5 W39.72 V × 13.01 A132.8 W96%
695 W520 W39.79 V × 13.07 A133.7 W96%
700 W523.5 W40.24 V × 13.01 A135.2 W97%
705 W527.3 W40.31 V × 13.08 A136.2 W97%
710 W531 W40.38 V × 13.15 A137.1 W97%
715 W534.5 W40.46 V × 13.21 A138 W97%
720 W538.5 W40.53 V × 13.29 A139.1 W97%
725 W542.5 W40.58 V × 13.37 A140.1 W97%
730 W546.1 W40.64 V × 13.44 A141 W97%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Certifications

CEC PV Module List (Oct 7, 2026) · Clean Energy Council (Australia)
UL 61730IEC 61215:2021 / IEC 61730:2023

Independent reliability testing

Kiwa PVEL Scorecard · RETC PV Module Index
2025
PVEL Top Performer
this series
4
Tests passed as Top Performer
LID+LETID, PAN, PID, TC
5
PVEL Scorecards
Risen Energy named Top Performer, 2021–2025
1
RETC PV Module Index
Risen Energy, 2025

PVEL Top Performer tests

YearProductTests
2025RSM132-8-xxxBHDGLID+LETIDPANPIDTC

Tested bill of materials

Details describe the tested sample, not every module of the series.

RETC PV Module Index — Risen Energy

YearRecognition
2025Test Category High Achiever

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
52.2 V
Voc when cold
per panel
35.9 V
Vmp when hot
per panel
11
Max panels / string
max DC 600 V
2
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet2–11
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–11
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet3–11
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window7–9

Microinverters (one per panel)

No microinverter in the reference set lists this power class in its recommended module power range.
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,6761,15611,5646.08
Palmdale1,8351,26612,6626.69
Chula Vista1,6961,17011,7026.11
Huntington Beach1,6431,13411,3375.89
Riverside1,6961,17011,7026.21
Santa Clarita1,7241,19011,8966.28
755Jan756Feb969Mar1,071Apr1,058May1,124Jun1,184Jul1,198Aug1,047Sep924Oct794Nov687DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 690 W panels

CEC PV Module List (Oct 7, 2026) · datasheets · Kiwa PVEL Scorecard
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)
Risen Energy RSM132-8-690BHDG690 W≈22.2%−0.26649.6517.66product 2025
Canadian Solar CS7N-690TB-AG690 W≈22.2%−0.28547.518.39product 2024
Waaree BiN-03-690690 W≥22.2%−0.30247.818.24brand 5× (2022–2026)
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

About Risen Energy

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · RETC PV Module Index

Other series by SoCal permits

RSM110-8-xxxBHDGRSM132-8-xxxBMDGRSM132-8-xxxMRSM110-8-xxxBMDGRSM110-8-xxxMRSM120-8-xxxBMDG

Questions & answers

How efficient is the Risen Energy RSM132-8-690BHDG?

Calculated from the panel area (3.11 m²): about 22.2% for the 690 W class. 690 W over 3.11 m² equals about 222 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 1,156 kWh per year per 690 W panel in Los Angeles and about 1,266 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.266 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 13.8% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–11 panels per string (Voc at 2 °C = 52.2 V, Vmp at 74 °C cell = 35.9 V). Final design must follow the inverter manual and NEC 690.7.

Is it bifacial?

Yes. Rear gain depends on mounting height and ground reflectance.

Has this panel been reliability-tested?

RSM132-8-xxxBHDG was a PVEL Top Performer in 2025 (LID+LETID, PAN, PID, TC).

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Canadian Solar — datasheet New N-type Bifacial Module TOPBiHiKu7 CS7N-725|730|735|740|745|750TB-AG.
  3. Waaree — datasheet ELITE SERIES BiN-03.
  4. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2021–2025.
  5. RETC — PV Module Index report.
  6. NLR (formerly NREL) — System Advisor Model CEC module and inverter libraries (version 2026.7.3).
  7. Clean Energy Council (Australia) — Approved PV modules list (as of Oct 8, 2026).
  8. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  9. Inverter datasheets — Solis (Ginlong), Tesla (manufacturer documents).
  10. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).