Cali-GrafCali-Graf
Solar panelRisen Energy

Risen Energy RSM110-8-540M

110 cells. Power classes 525–560 W in the CEC list.

CEC listed · Dec 13, 2021UL 61730PVEL Top Performer 2023
Power class
  • Power (STC)540 WCEC nameplate
  • Efficiency≈20.8%calculated from area
  • %/°C Pmax−0.325CEC listing test
  • PTC / STC93.8%PTC 507 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 8 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
RSM110-8-525M525 W37.1818.0330.8617.02≈20.2%492 WDec 13, 2021
RSM110-8-530M530 W37.3818.0831.0617.07≈20.4%497 WDec 13, 2021
RSM110-8-535M535 W37.5818.1331.2617.12≈20.6%502 WDec 13, 2021
RSM110-8-540M540 W37.7818.1831.4617.17≈20.8%507 WDec 13, 2021
RSM110-8-545M545 W38.0218.2331.6617.22≈21.0%511 WDec 13, 2021
RSM110-8-550M550 W38.2418.2831.8617.27≈21.2%516 WDec 13, 2021
RSM110-8-555M555 W38.4618.3332.0617.32≈21.3%521 WDec 13, 2021
RSM110-8-560M560 W38.6818.3832.2617.37≈21.5%526 WDec 13, 2021
≈ efficiency = Pmax ÷ CEC-listed area 2.6 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.325 %/°C
Voc coefficient β−0.249 %/°C
Isc coefficient α+0.018 %/°C
Operating cell temperatureNOCT 45 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
525 W389 W28.37 V × 13.71 A99.8 W95%
530 W392.7 W28.55 V × 13.76 A100.7 W95%
535 W396.4 W28.73 V × 13.8 A101.7 W95%
540 W400.1 W28.92 V × 13.84 A102.6 W95%
545 W403.8 W29.1 V × 13.88 A103.6 W95%
550 W407.5 W29.28 V × 13.92 A104.5 W95%
555 W411.3 W29.47 V × 13.96 A105.5 W95%
560 W415 W29.65 V × 14 A106.4 W95%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Certifications

CEC PV Module List (Oct 7, 2026) · Clean Energy Council (Australia)
UL 61730IEC 61215:2021 / IEC 61730:2023

Independent reliability testing

Kiwa PVEL Scorecard · RETC PV Module Index
2023
PVEL Top Performer
this series
1
Tests passed as Top Performer
LID+LETID
5
PVEL Scorecards
Risen Energy named Top Performer, 2021–2025
1
RETC PV Module Index
Risen Energy, 2025

PVEL Top Performer tests

YearProductTests
2023RSM110-8-xxxMLID+LETID

Tested bill of materials

Details describe the tested sample, not every module of the series.

RETC PV Module Index — Risen Energy

YearRecognition
2025Test Category High Achiever

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
39.9 V
Voc when cold
per panel
26.2 V
Vmp when hot
per panel
15
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–15
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet4–15
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–15
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window9–12

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V39.9 / 26.2 V✗ Not a match: module voltage below MPPT range1.42
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V39.9 / 26.2 V⚠ Works; below MPPT at peak heat0.69
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67690511,7666.08
Palmdale1,83599112,8826.69
Chula Vista1,69691611,9066.11
Huntington Beach1,64388711,5345.89
Riverside1,69691611,9066.21
Santa Clarita1,72493112,1026.28
768Jan769Feb986Mar1,090Apr1,076May1,144Jun1,205Jul1,219Aug1,066Sep940Oct808Nov699DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 540 W panels

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · datasheets · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
Risen Energy RSM110-8-540M540 W≈20.8%−0.32537.7818.18product 2023—
JA Solar JAM72D30-540/MB540 W≈21.4%−0.33049.613.86product 2023, 20243
Canadian Solar CS6W-540MB-AG540 W≈21%−0.32449.213.9product 20241
LONGi LR5-72HBD-540M540 W≥21.1%−0.35449.513.85product 20261
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

About Risen Energy

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · RETC PV Module Index

Other series by SoCal permits

RSM132-8-xxxBHDGRSM110-8-xxxBHDGRSM132-8-xxxBMDGRSM132-8-xxxMRSM110-8-xxxBMDGRSM120-8-xxxBMDG

Questions & answers

How efficient is the Risen Energy RSM110-8-540M?

Calculated from the panel area (2.6 m²): about 20.8% for the 540 W class. 540 W over 2.6 m² equals about 208 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 905 kWh per year per 540 W panel in Los Angeles and about 991 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.325 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 16.8% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–15 panels per string (Voc at 2 °C = 39.9 V, Vmp at 74 °C cell = 26.2 V). Final design must follow the inverter manual and NEC 690.7.

Has this panel been reliability-tested?

RSM110-8-xxxM was a PVEL Top Performer in 2023 (LID+LETID).

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Canadian Solar — datasheet BiHiKu6 BIFACIAL MONO PERC CS6W-520|525|530|535|540|545|550MB-AG.
  3. LONGi — manufacturer datasheet “LR5-72HBD Suitable for distributed projects Advanced module technology delivers superior”.
  4. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2021–2025.
  5. RETC — PV Module Index report.
  6. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  7. Clean Energy Council (Australia) — Approved PV modules list (as of Oct 8, 2026).
  8. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  9. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  10. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  11. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).