Solar panelResun Solar

Resun Solar RS8K470M-DG

120 cells, bifacial. Power classes 460–485 W in the CEC list.

CEC listed · Oct 1, 2025UL 61730Bifacial
Power class
  • Power (STC)470 WCEC nameplate
  • Efficiency≈21.8%calculated from area
  • %/°C Pmax−0.303CEC listing test
  • PTC / STC94.1%PTC 442 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 6 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
RS8K460M-DG460 W42.3013.8935.1513.09≈21.3%432 WOct 1, 2025
RS8K465M-DG465 W42.4513.9835.3013.18≈21.5%437 WOct 1, 2025
RS8K470M-DG470 W42.6014.0635.4513.26≈21.8%442 WOct 1, 2025
RS8K475M-DG475 W42.7514.1535.6013.35≈22.0%447 WOct 1, 2025
RS8K480M-DG480 W42.9014.2335.7513.43≈22.2%452 WOct 1, 2025
RS8K485M-DG485 W43.0514.3135.9013.51≈22.5%457 WOct 1, 2025
≈ efficiency = Pmax ÷ CEC-listed area 2.16 m².

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.303 %/°C
Voc coefficient β−0.247 %/°C
Isc coefficient α+0.044 %/°C
Operating cell temperatureNOCT 45.9 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
460 W345.3 W33.18 V × 10.41 A90 W98%
465 W349.2 W33.32 V × 10.48 A91 W98%
470 W352.8 W33.47 V × 10.54 A92 W98%
475 W356.7 W33.61 V × 10.61 A93 W98%
480 W360.3 W33.75 V × 10.68 A93.9 W98%
485 W364 W33.89 V × 10.74 A94.9 W98%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
45 V
Voc when cold
per panel
29.4 V
Vmp when hot
per panel
13
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–13
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–13
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–13
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window8–11

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V45 / 29.4 V✗ Not a match: module voltage below MPPT range1.24
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V45 / 29.4 V✓ Within range0.6
Enphase IQ8A-72-2-US295–500 W60 V32–45 V45 / 29.4 V⚠ Works; below MPPT at peak heat1.35
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67678811,8166.08
Palmdale1,83586212,9376.69
Chula Vista1,69679711,9576.11
Huntington Beach1,64377211,5835.89
Riverside1,69679711,9576.21
Santa Clarita1,72481012,1546.28
771Jan772Feb991Mar1,094Apr1,081May1,148Jun1,210Jul1,224Aug1,070Sep944Oct811Nov702DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 470 W panels

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · datasheets · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, ASoCal permits (series)
Resun Solar RS8K470M-DG470 W≈21.8%−0.30342.614.06—
REC Group REC470AA Pure-RX470 W≈23.3%−0.24865.78.9533
Aptos Solar DNA-120-MF10-465W465 W≈21.5%−0.36341.914.0722
Canadian Solar CS6.1-54TM-465H465 W≥22.8%−0.30839.514.779
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the Resun Solar RS8K470M-DG?

Calculated from the panel area (2.16 m²): about 21.8% for the 470 W class. 470 W over 2.16 m² equals about 218 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 788 kWh per year per 470 W panel in Los Angeles and about 862 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.303 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 15.7% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–13 panels per string (Voc at 2 °C = 45 V, Vmp at 74 °C cell = 29.4 V). Final design must follow the inverter manual and NEC 690.7.

Does it work with APsystems (Alt Power System) DS3-L microinverters?

Voltage check against the APsystems (Alt Power System) datasheet: Voc when cold 45 V vs max input 60 V; Vmp when hot 29.4 V vs MPPT low 28 V; recommended module power 265–570 W. Confirm on the microinverter maker’s compatibility list.

Is it bifacial?

Yes. Rear gain depends on mounting height and ground reflectance.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Aptos Solar — datasheet Legacy Products.
  3. Canadian Solar — datasheet TOPHiKu6 (All-Black) N-type TOPCon Technology CS6.1-54TM-435|440|445|450|455|460|465H.
  4. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
  5. NLR (formerly NREL) — System Advisor Model CEC module and inverter libraries (version 2026.7.3).
  6. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  7. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  8. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  9. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).