Cali-GrafCali-Graf
Solar panelRegitec Solar

Regitec Solar RMHT54/425AB3

108 half-cut cells. 425 W in the CEC list.

CEC listed · Mar 2, 2026UL 61730
  • Power (STC)425 WCEC nameplate
  • Efficiency≈21.8%calculated from area
  • %/°C Pmax−0.299CEC listing test
  • PTC / STC93.9%PTC 399 W (CEC)

Electrical ratings (STC)

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
RMHT54/425AB3425 W38.3014.1531.7013.41≈21.8%399 WMar 2, 2026
≈ efficiency = Pmax ÷ CEC-listed area 1.95 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.299 %/°C
Voc coefficient β−0.247 %/°C
Isc coefficient α+0.044 %/°C
Operating cell temperatureNOCT 46.8 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
425 W319.5 W30.49 V × 10.48 A82.2 W97%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
40.5 V
Voc when cold
per panel
26.4 V
Vmp when hot
per panel
14
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–14
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet4–14
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–14
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window9–12

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V40.5 / 26.4 V⚠ Works; below MPPT at peak heat1.47
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V40.5 / 26.4 V✗ Not a match: module voltage below MPPT range1.12
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V40.5 / 26.4 V⚠ Works; below MPPT at peak heat0.54
Enphase IQ8M-72-2-US260–460 W60 V30–45 V40.5 / 26.4 V⚠ Works; below MPPT at peak heat1.31
Enphase IQ8A-72-2-US295–500 W60 V32–45 V40.5 / 26.4 V✗ Not a match: module voltage below MPPT range1.22
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67671211,3976.08
Palmdale1,83578012,4786.69
Chula Vista1,69672111,5336.11
Huntington Beach1,64369811,1725.89
Riverside1,69672111,5336.21
Santa Clarita1,72473311,7236.28
744Jan745Feb955Mar1,055Apr1,042May1,108Jun1,167Jul1,180Aug1,032Sep911Oct783Nov677DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 425 W panels

CEC PV Module List (Oct 7, 2026) · datasheets · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, AWarrantyPVEL (product / brand)SoCal permits (series)
Regitec Solar RMHT54/425AB3425 W≈21.8%−0.29938.314.15———
Canadian Solar CS3N-425MS425 W≥20.9%−0.33245.511.825 yrproduct 202346
Qcells Q.TRON BLK M-G2+ 425425 W≥21.8%−0.27639.0313.6625 / 25 yrbrand 11× (2016–2026)40
Silfab Solar SIL-425QD425 W≈21.8%−0.29438.8813.6825 / 30 yrbrand 7× (2017–2025)39
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the Regitec Solar RMHT54/425AB3?

Calculated from the panel area (1.95 m²): about 21.8% for the 425 W class. 425 W over 1.95 m² equals about 218 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 712 kWh per year per 425 W panel in Los Angeles and about 780 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.299 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 15.5% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–14 panels per string (Voc at 2 °C = 40.5 V, Vmp at 74 °C cell = 26.4 V). Final design must follow the inverter manual and NEC 690.7.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Canadian Solar — manufacturer datasheet “HiKu Mono PERC CS3N-400|405|410|415|420|425MS MORE POWER”.
  3. Qcells — manufacturer datasheet “Q.TRON BLK M-G2+ SERIES 415–440 Wp”.
  4. Silfab Solar — datasheet NTC SIL-420 QD CELL TECHNOLOGY.
  5. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
  6. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  7. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  8. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  9. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  10. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).