Cali-GrafCali-Graf
Solar panelRECOM

RECOM RCM-320-6PA

72 cells. Power classes 285–350 W in the CEC list.

CEC listed · Apr 21, 2020UL 1703
Power class
  • Power (STC)320 WCEC nameplate
  • Efficiency≈16.5%calculated from area
  • %/°C Pmax−0.400CEC listing test
  • PTC / STC91%PTC 291 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 17 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTC
RCM-285-6PA285 W44.708.4436.207.94≈14.7%257 W
RCM-290-6PA290 W44.808.5636.308.00≈14.9%262 W
RCM-295-6PA295 W44.908.6736.408.11≈15.2%266 W
RCM-300-6PA300 W44.808.6936.608.20≈15.5%271 W
RCM-305-6PA305 W44.958.7736.828.33≈15.7%275 W
RCM-310-6PA310 W45.008.9237.008.42≈16.0%280 W
RCM-315-6PA315 W45.408.9537.808.44≈16.2%287 W
RCM-320-6PA320 W45.948.9938.238.46≈16.5%291 W
RCM-320-6PA320 W46.509.1537.658.50≈16.7%289 W
RCM-325-6PA325 W46.159.0238.478.49≈16.7%296 W
RCM-325-6PA325 W46.609.2037.808.60≈16.9%293 W
RCM-330-6PA330 W46.519.0738.838.54≈17.0%301 W
RCM-330-6PA330 W46.709.2537.958.70≈17.2%298 W
RCM-335-6PA335 W46.809.3038.108.80≈17.4%303 W
RCM-340-6PA340 W46.909.3538.258.90≈17.7%310 W
RCM-345-6PA345 W47.009.4038.558.95≈18.0%314 W
RCM-350-6PA350 W47.109.4538.909.00≈18.2%319 W
≈ efficiency = Pmax ÷ CEC-listed area 1.94 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.400 %/°C
Voc coefficient β−0.300 %/°C
Isc coefficient α+0.050 %/°C
Vmp coefficient−0.390 %/°C
Operating cell temperatureNOCT 46.9 °C

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
285 W210.2 W33 V × 6.37 A55.1 W97%
290 W212.4 W33.09 V × 6.42 A55.6 W96%
295 W216 W33.18 V × 6.51 A56.4 W96%
300 W219.5 W33.36 V × 6.58 A57.4 W96%
305 W224.5 W33.56 V × 6.69 A58.5 W96%
310 W228 W33.73 V × 6.76 A59.5 W96%
315 W233.6 W34.56 V × 6.76 A61.3 W97%
320 W236.8 W34.96 V × 6.77 A62.1 W97%
320 W235.8 W34.51 V × 6.83 A59.3 W93%
325 W239.1 W35.17 V × 6.8 A62.7 W96%
325 W239.5 W34.65 V × 6.91 A60.2 W93%
330 W242.8 W35.5 V × 6.84 A63.7 W96%
330 W243.2 W34.78 V × 6.99 A61.1 W93%
335 W247 W34.92 V × 7.07 A62.1 W93%
340 W250.7 W35.27 V × 7.11 A65.6 W96%
345 W254.1 W35.54 V × 7.15 A66.4 W96%
350 W257.8 W35.87 V × 7.19 A67.4 W96%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
49.1 V
Voc when cold
per panel
30.9 V
Vmp when hot
per panel
12
Max panels / string
max DC 600 V
2
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet2–12
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–12
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–12
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window8–10

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V49.1 / 30.9 V✓ Within range1.1
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V49.1 / 30.9 V✗ Not a match: module voltage below MPPT range0.84
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V49.1 / 30.9 V✓ Within range0.41
Enphase IQ8M-72-2-US260–460 W60 V30–45 V49.1 / 30.9 V✓ Within range0.98
Enphase IQ8A-72-2-US295–500 W60 V32–45 V49.1 / 30.9 V⚠ Works; below MPPT at peak heat0.92
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67653611,7996.08
Palmdale1,83558712,9186.69
Chula Vista1,69654311,9406.11
Huntington Beach1,64352611,5675.89
Riverside1,69654311,9406.21
Santa Clarita1,72455212,1376.28
770Jan771Feb989Mar1,093Apr1,079May1,147Jun1,208Jul1,222Aug1,069Sep943Oct810Nov701DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 320 W panels

CEC PV Module List (Oct 7, 2026) · datasheets · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, ASizePVEL (product / brand)SoCal permits (series)
RECOM RCM-320-6PA320 W≈16.5%−0.40045.948.9977 in——
JinkoSolar JKM320M-60HBL320 W≈19%−0.40740.910.1566.3 × 39.4 inbrand 12× (2014–2026)45
LG Electronics LG320N1C-N5320 W≈18.5%−0.34240.810.5366.9 × 40 inproduct 20215
REC Group REC320NP320 W≈19.8%−0.35140.810.18—brand 9× (2016–2025)4
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the RECOM RCM-320-6PA?

Calculated from the panel area (1.94 m²): about 16.5% for the 320 W class. 320 W over 1.94 m² equals about 165 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 536 kWh per year per 320 W panel in Los Angeles and about 587 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.400 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 20.7% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–12 panels per string (Voc at 2 °C = 49.1 V, Vmp at 74 °C cell = 30.9 V). Final design must follow the inverter manual and NEC 690.7.

Does it work with Enphase IQ8PLUS-72-2-US microinverters?

Voltage check against the Enphase datasheet: Voc when cold 49.1 V vs max input 60 V; Vmp when hot 30.9 V vs MPPT low 29 V; recommended module power 235–440 W. Confirm on the microinverter maker’s compatibility list.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. JinkoSolar — datasheet THE MOST DEPENDABLE SOLAR BRAND.
  3. JinkoSolar — manufacturer datasheet “Eagle HC 60M G2 315-335 Watt MONO PERC HALF CELL MODULE”.
  4. LG Electronics — datasheet Specification Sheet.
  5. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
  6. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  7. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  8. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  9. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  10. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).