Cali-GrafCali-Graf
Solar panelRECOM

RECOM RCM-350-6MA

72 cells. Power classes 315–385 W in the CEC list.

CEC listed · Apr 21, 2020UL 61730
Power class
  • Power (STC)350 WCEC nameplate
  • Efficiency≈18.2%calculated from area
  • %/°C Pmax−0.414CEC listing test
  • PTC / STC91.6%PTC 321 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 15 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
RCM-315-6MA315 W46.708.6838.208.32≈16.2%286 W—
RCM-320-6MA320 W46.808.7538.308.42≈16.5%290 W—
RCM-325-6MA325 W47.008.8038.408.49≈16.7%295 W—
RCM-330-6MA330 W47.108.8638.508.61≈17.0%300 W—
RCM-335-6MA335 W47.408.9338.708.73≈17.3%304 W—
RCM-340-6MA340 W47.608.9938.808.82≈17.5%309 W—
RCM-345-6MA345 W47.909.0538.908.91≈17.8%314 W—
RCM-350-6MA350 W47.359.6038.509.10≈18.2%321 WApr 21, 2020
RCM-355-6MA355 W47.459.6538.709.18≈18.5%325 WApr 21, 2020
RCM-360-6MA360 W47.659.7038.909.26≈18.8%330 WApr 21, 2020
RCM-365-6MA365 W47.859.7539.109.34≈19.0%335 WApr 21, 2020
RCM-370-6MA370 W48.059.8039.309.42≈19.3%340 WApr 21, 2020
RCM-375-6MA375 W48.259.8539.509.50≈19.5%348 WApr 21, 2020
RCM-380-6MA380 W48.459.9039.709.58≈19.8%353 WApr 21, 2020
RCM-385-6MA385 W48.659.9539.909.65≈20.1%358 WApr 21, 2020
≈ efficiency = Pmax ÷ CEC-listed area 1.94 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.414 %/°C
Voc coefficient β−0.321 %/°C
Isc coefficient α+0.064 %/°C
Operating cell temperatureNOCT 45.3 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
315 W232.8 W35.38 V × 6.58 A59.8 W95%
320 W236.2 W35.47 V × 6.66 A60.7 W95%
325 W238.8 W35.57 V × 6.71 A61.4 W94%
330 W242.8 W35.66 V × 6.81 A62.4 W95%
335 W247.5 W35.84 V × 6.9 A63.6 W95%
340 W250.7 W35.94 V × 6.97 A64.4 W95%
345 W253.9 W36.03 V × 7.05 A65.2 W95%
350 W256.8 W35.86 V × 7.16 A66.3 W95%
355 W260.4 W36.05 V × 7.23 A67.2 W95%
360 W264.1 W36.23 V × 7.29 A68.2 W95%
365 W267.7 W36.42 V × 7.35 A69.1 W95%
370 W271.4 W36.61 V × 7.41 A70 W95%
375 W274.7 W37.02 V × 7.42 A71.1 W95%
380 W278.4 W37.21 V × 7.48 A72 W95%
385 W281.9 W37.4 V × 7.54 A72.9 W95%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
50.8 V
Voc when cold
per panel
29.5 V
Vmp when hot
per panel
11
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–11
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–11
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–11
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window8–9

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V50.8 / 29.5 V✓ Within range1.21
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V50.8 / 29.5 V✗ Not a match: module voltage below MPPT range0.92
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V50.8 / 29.5 V✓ Within range0.45
Enphase IQ8M-72-2-US260–460 W60 V30–45 V50.8 / 29.5 V⚠ Works; below MPPT at peak heat1.08
Enphase IQ8A-72-2-US295–500 W60 V32–45 V50.8 / 29.5 V⚠ Works; below MPPT at peak heat1
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67658711,7326.08
Palmdale1,83564212,8456.69
Chula Vista1,69659411,8726.11
Huntington Beach1,64357511,5015.89
Riverside1,69659411,8726.21
Santa Clarita1,72460312,0686.28
766Jan766Feb984Mar1,086Apr1,073May1,140Jun1,201Jul1,215Aug1,063Sep937Oct806Nov697DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 350 W panels

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · JinkoSolar datasheets · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
RECOM RCM-350-6MA350 W≈18.2%−0.41447.359.6——
LONGi LR4-60HPB-350M350 W≈19.8%−0.33940.411.16product 2021, 2022193
JinkoSolar JKM345M-60HBL345 W≈20.4%−0.40641.210.91brand 12× (2014–2026)45
REC Group REC350AA350 W≈20.8%−0.27943.810.16brand 9× (2016–2025)30
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the RECOM RCM-350-6MA?

Calculated from the panel area (1.94 m²): about 18.2% for the 350 W class. 350 W over 1.94 m² equals about 180 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 587 kWh per year per 350 W panel in Los Angeles and about 642 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.414 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 21.5% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–11 panels per string (Voc at 2 °C = 50.8 V, Vmp at 74 °C cell = 29.5 V). Final design must follow the inverter manual and NEC 690.7.

Does it work with Enphase IQ8PLUS-72-2-US microinverters?

Voltage check against the Enphase datasheet: Voc when cold 50.8 V vs max input 60 V; Vmp when hot 29.5 V vs MPPT low 29 V; recommended module power 235–440 W. Confirm on the microinverter maker’s compatibility list.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. JinkoSolar — datasheet THE MOST DEPENDABLE SOLAR BRAND.
  3. JinkoSolar — manufacturer datasheet “Eagle HC 60M G2 315-335 Watt MONO PERC HALF CELL MODULE”.
  4. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
  5. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  6. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  7. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  8. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  9. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).