Cali-GrafCali-Graf
Solar panelREC Group

REC Group REC325TP3M

120 half-cut cells. Power classes 315–340 W in the CEC list.

CEC listed · Sep 11, 2020UL 61730Installed in 4 SoCal permits
Power class
  • Power (STC)325 WCEC nameplate
  • Efficiency≈20.2%calculated from area
  • %/°C Pmax−0.336CEC listing test
  • PTC / STC93.5%PTC 304 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 6 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
REC315TP3M315 W38.7010.2933.609.38≈19.6%294 WSep 11, 2020
REC320TP3M320 W39.1010.3233.809.46≈19.9%299 WSep 11, 2020
REC325TP3M325 W39.5010.3634.109.54≈20.2%304 WSep 11, 2020
REC330TP3M330 W39.9010.3934.309.62≈20.5%309 WSep 11, 2020
REC335TP3M335 W40.2010.4234.609.69≈20.8%314 WSep 11, 2020
REC340TP3M340 W40.6010.4534.709.79≈21.1%318 WSep 11, 2020
≈ efficiency = Pmax ÷ CEC-listed area 1.61 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.336 %/°C
Voc coefficient β−0.264 %/°C
Isc coefficient α+0.038 %/°C
Operating cell temperatureNOCT 45 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
315 W230.9 W31.21 V × 7.4 A58.2 W92%
320 W234.2 W31.4 V × 7.46 A59.1 W92%
325 W238.3 W31.68 V × 7.52 A60.1 W92%
330 W241.7 W31.86 V × 7.59 A60.9 W92%
335 W245.6 W32.14 V × 7.64 A61.9 W92%
340 W248.8 W32.23 V × 7.72 A62.7 W92%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Independent reliability testing

Kiwa PVEL Scorecard · RETC PV Module Index
9
PVEL Scorecards
REC Group named Top Performer, 2016–2025
3
RETC PV Module Index
REC Group recognized 2023–2025
This exact series is not listed in published PVEL Top Performer tables. Results below are for the manufacturer.

RETC PV Module Index — REC Group

YearRecognition
2023High Achievement in Performance (Ptc-to-stc ratio, Module efficiency)
2024High Achievement in Performance
2025Test Category High Achiever

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
41.9 V
Voc when cold
per panel
27.9 V
Vmp when hot
per panel
14
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–14
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–14
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–14
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window9–11

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V41.9 / 27.9 V⚠ Works; below MPPT at peak heat1.12
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V41.9 / 27.9 V✗ Not a match: module voltage below MPPT range0.86
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V41.9 / 27.9 V⚠ Works; below MPPT at peak heat0.42
Enphase IQ8M-72-2-US260–460 W60 V30–45 V41.9 / 27.9 V⚠ Works; below MPPT at peak heat1
Enphase IQ8A-72-2-US295–500 W60 V32–45 V41.9 / 27.9 V⚠ Works; below MPPT at peak heat0.93
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67654511,9836.08
Palmdale1,83559613,1206.69
Chula Vista1,69655112,1266.11
Huntington Beach1,64353411,7475.89
Riverside1,69655112,1266.21
Santa Clarita1,72456012,3276.28
782Jan783Feb1,005Mar1,110Apr1,096May1,165Jun1,227Jul1,241Aug1,085Sep957Oct823Nov712DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Who installs RECxxxTP3M panels in SoCal

building permits
4
Permits naming this series
Apr 2021 – Sep 2021
1
Jurisdictions so far
LA County (unincorp.) (4)

Permits over time

1Apr ’210May0Jun0Jul1Aug2Seppermits per month
Only installer and ZIP level is shown — no homeowner names, street addresses or permit numbers. Permits from LA County (unincorp.) come without a contractor license, so they count toward totals but not toward installers. Counts grow as more permit portals are loaded.

Installed together with

building permits

Microinverters

Enphase IQ7
3
Number of permits naming both this panel series and the product; 4 of 4 permits list other equipment.

Compare with similar 325 W panels

CEC PV Module List (Oct 7, 2026) · datasheets · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, ASizeWarrantyPVEL (product / brand)SoCal permits (series)
REC Group REC325TP3M325 W≈20.2%−0.33639.510.36——brand 9×4
JinkoSolar JKM325M-60HBL325 W≈19.3%−0.40741.110.266.3 × 39.4 in10 / 25 yrbrand 12× (2014–2026)45
Qcells Q.PEAK DUO-G8+ 330330 W≈18.4%−0.34339.7110.5268.5 × 40.6 in25 / 25 yrproduct 202220
LG Electronics LG325N1C-N5325 W≈18.8%−0.34240.910.5766.9 × 40 in25 / 25 yrproduct 20215
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

About REC Group

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · RETC PV Module Index · building permits

Other series by SoCal permits

RECxxxAA Pure · 66RECxxxAA Pure-RX · 33RECxxxAA · 30RECxxxAA Black · 8RECxxxNP3 Black · 7RECxxxAA Pure 2 · 6

Questions & answers

How efficient is the REC Group REC325TP3M?

Calculated from the panel area (1.61 m²): about 20.2% for the 325 W class. 325 W over 1.61 m² equals about 202 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 545 kWh per year per 325 W panel in Los Angeles and about 596 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.336 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 17.4% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–14 panels per string (Voc at 2 °C = 41.9 V, Vmp at 74 °C cell = 27.9 V). Final design must follow the inverter manual and NEC 690.7.

Has this panel been reliability-tested?

This exact series is not in published PVEL Top Performer tables; REC Group was named a Top Performer in 9 Scorecards (2016–2025).

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. JinkoSolar — datasheet THE MOST DEPENDABLE SOLAR BRAND.
  3. JinkoSolar — manufacturer datasheet “Eagle HC 60M G2 315-335 Watt MONO PERC HALF CELL MODULE”.
  4. Qcells — manufacturer datasheet “Q.PEAK DUO-G8+ 345-360 EN ENDURING HIGH”.
  5. LG Electronics — datasheet Specification Sheet.
  6. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2016–2025.
  7. RETC — PV Module Index reports 2023–2025.
  8. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  9. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  10. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  11. Building permits — Los Angeles County Public Works (EPIC-LA, unincorporated areas) (Apr 2021 – Sep 2021). Equipment matched from permit descriptions by model number.
  12. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).