Cali-GrafCali-Graf
Solar panelREC Group

REC Group REC360NP2

120 half-cut cells. Power classes 345–380 W in the CEC list.

CEC listed · Oct 1, 2021UL 61730Installed in 1 SoCal permit
Power class
  • Power (STC)360 WCEC nameplate
  • Efficiency≈20.3%calculated from area
  • %/°C Pmax−0.323CEC listing test
  • PTC / STC94.1%PTC 339 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 8 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
REC345NP2345 W40.4011.1932.7010.54≈19.5%324 WJul 21, 2022
REC350NP2350 W40.6011.2233.1010.57≈19.8%329 WJan 11, 2022
REC355NP2355 W40.7011.2733.5010.60≈20.1%334 WOct 1, 2021
REC360NP2360 W40.8011.3133.9010.62≈20.3%339 WOct 1, 2021
REC365NP2365 W40.9011.3634.3010.65≈20.6%344 WOct 1, 2021
REC370NP2370 W41.1011.4134.7010.68≈20.9%348 WOct 1, 2021
REC375NP2375 W41.3011.4635.0010.72≈21.2%353 WOct 1, 2021
REC380NP2380 W41.4011.5135.3010.77≈21.5%358 WOct 1, 2021
≈ efficiency = Pmax ÷ CEC-listed area 1.77 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.323 %/°C
Voc coefficient β−0.252 %/°C
Isc coefficient α+0.036 %/°C
Operating cell temperatureNOCT 43.9 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
345 W255.2 W30.96 V × 8.24 A64.3 W93%
350 W259 W31.34 V × 8.26 A65.3 W93%
355 W262.9 W31.72 V × 8.29 A66.3 W93%
360 W266.5 W32.1 V × 8.3 A67.2 W93%
365 W270.4 W32.48 V × 8.33 A68.2 W93%
370 W274.4 W32.85 V × 8.35 A69.2 W93%
375 W277.8 W33.14 V × 8.38 A70 W93%
380 W281.5 W33.42 V × 8.42 A71 W93%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Independent reliability testing

Kiwa PVEL Scorecard · RETC PV Module Index
9
PVEL Scorecards
REC Group named Top Performer, 2016–2025
3
RETC PV Module Index
REC Group recognized 2023–2025
This exact series is not listed in published PVEL Top Performer tables. Results below are for the manufacturer.

RETC PV Module Index — REC Group

YearRecognition
2023High Achievement in Performance (Ptc-to-stc ratio, Module efficiency)
2024High Achievement in Performance
2025Test Category High Achiever

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
43.2 V
Voc when cold
per panel
27.9 V
Vmp when hot
per panel
13
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–13
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–13
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–13
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window9–11

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V43.2 / 27.9 V⚠ Works; below MPPT at peak heat1.24
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V43.2 / 27.9 V✗ Not a match: module voltage below MPPT range0.95
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V43.2 / 27.9 V⚠ Works; below MPPT at peak heat0.46
Enphase IQ8M-72-2-US260–460 W60 V30–45 V43.2 / 27.9 V⚠ Works; below MPPT at peak heat1.11
Enphase IQ8A-72-2-US295–500 W60 V32–45 V43.2 / 27.9 V⚠ Works; below MPPT at peak heat1.03
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67660311,4646.08
Palmdale1,83566112,5516.69
Chula Vista1,69661111,6016.11
Huntington Beach1,64359111,2385.89
Riverside1,69661111,6016.21
Santa Clarita1,72462111,7926.28
748Jan749Feb961Mar1,062Apr1,049May1,114Jun1,174Jul1,187Aug1,038Sep916Oct787Nov681DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Who installs RECxxxNP2 panels in SoCal

building permits · CSLB License Master
1
Permits naming this series
Dec 2022
1
Licensed installers
CSLB license on the permit
1
Jurisdictions so far
Los Angeles (1)
Only installer and ZIP level is shown — no homeowner names, street addresses or permit numbers. Counts grow as more permit portals are loaded.

Compare with similar 360 W panels

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · Qcells datasheet · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
REC Group REC360NP2360 W≈20.3%−0.32340.811.31brand 9×1
LONGi LR4-60HPB-360M360 W≈20.3%−0.33940.811.33product 2021, 2022193
Trina Solar TSM-360DE06X.05(II)360 W≈19.8%−0.33944.810.3product 202223
Qcells Q.PEAK DUO-G8+ 360360 W≥20.1%−0.34341.1910.84product 202220
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

About REC Group

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · RETC PV Module Index · building permits

Other series by SoCal permits

RECxxxAA Pure · 66RECxxxAA Pure-RX · 33RECxxxAA · 30RECxxxAA Black · 8RECxxxNP3 Black · 7RECxxxAA Pure 2 · 6

Questions & answers

How efficient is the REC Group REC360NP2?

Calculated from the panel area (1.77 m²): about 20.3% for the 360 W class. 360 W over 1.77 m² equals about 203 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 603 kWh per year per 360 W panel in Los Angeles and about 661 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.323 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 16.7% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–13 panels per string (Voc at 2 °C = 43.2 V, Vmp at 74 °C cell = 27.9 V). Final design must follow the inverter manual and NEC 690.7.

Has this panel been reliability-tested?

This exact series is not in published PVEL Top Performer tables; REC Group was named a Top Performer in 9 Scorecards (2016–2025).

Who installs it in Southern California?

Building permits name this series 1 times (Dec 2022). The most active licensed installers are Citadel Roofing And Solar.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Qcells — manufacturer datasheet “Q.PEAK DUO-G8+ 345-360 EN ENDURING HIGH”.
  3. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2016–2025.
  4. RETC — PV Module Index reports 2023–2025.
  5. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  6. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  7. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  8. Building permits — LADBS, City of Los Angeles (Dec 2022). Equipment matched from permit descriptions by model number.
  9. Contractors State License Board — License Master (contractor names and license status), as of Oct 5, 2026.
  10. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).