88 half-cut cells. Power classes 440–475 W in the CEC list.

CEC listed · Mar 11, 2026UL 61730Installed in 3 SoCal permits
Power class
  • Power (STC)460 WCEC nameplate
  • Efficiency≈22.8%calculated from area
  • %/°C Pmax−0.248CEC listing test
  • PTC / STC95.4%PTC 439 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 8 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
REC440AA Pure-RX-DC440 W65.608.7453.708.20≈21.8%419 WMar 11, 2026
REC445AA Pure-RX-DC445 W65.608.7754.008.25≈22.0%424 WMar 11, 2026
REC450AA Pure-RX-DC450 W65.608.8154.308.29≈22.3%429 WMar 11, 2026
REC455AA Pure-RX-DC455 W65.608.8454.608.34≈22.5%434 WMar 11, 2026
REC460AA Pure-RX-DC460 W65.708.8854.908.38≈22.8%439 WMar 11, 2026
REC465AA Pure-RX-DC465 W65.708.9155.208.43≈23.0%444 WMar 11, 2026
REC470AA Pure-RX-DC470 W65.708.9555.408.49≈23.3%449 WMar 11, 2026
REC475AA Pure-RX-DC475 W65.709.0055.508.56≈23.5%454 WMar 11, 2026
≈ efficiency = Pmax ÷ CEC-listed area 2.02 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.248 %/°C
Voc coefficient β−0.233 %/°C
Isc coefficient α+0.042 %/°C
Operating cell temperatureNOCT 45.2 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
440 W325.5 W52.36 V × 6.22 A82 W93%
445 W329.3 W52.65 V × 6.26 A82.9 W93%
450 W332.8 W52.94 V × 6.29 A83.8 W93%
455 W336.6 W53.23 V × 6.32 A84.7 W93%
460 W340.1 W53.53 V × 6.35 A85.6 W93%
465 W344 W53.82 V × 6.39 A86.6 W93%
470 W347.7 W54.01 V × 6.44 A87.5 W93%
475 W351.2 W54.11 V × 6.49 A88.4 W93%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Independent reliability testing

Kiwa PVEL Scorecard · RETC PV Module Index
9
PVEL Scorecards
REC Group named Top Performer, 2016–2025
3
RETC PV Module Index
REC Group recognized 2023–2025
This exact series is not listed in published PVEL Top Performer tables. Results below are for the manufacturer.

RETC PV Module Index — REC Group

YearRecognition
2023High Achievement in Performance (Ptc-to-stc ratio, Module efficiency)
2024High Achievement in Performance
2025Test Category High Achiever

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
69.2 V
Voc when cold
per panel
47.1 V
Vmp when hot
per panel
8
Max panels / string
max DC 600 V
2
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet2–8
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet2–8
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet3–8
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window5–7

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V69.2 / 47.1 V✓ Within range1.21
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V69.2 / 47.1 V✗ Not allowed: cold Voc above max input0.59
Enphase IQ8M-72-2-US260–460 W60 V30–45 V69.2 / 47.1 V✗ Not allowed: cold Voc above max input1.42
Enphase IQ8A-72-2-US295–500 W60 V32–45 V69.2 / 47.1 V✗ Not allowed: cold Voc above max input1.32
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67677111,5646.08
Palmdale1,83584412,6626.69
Chula Vista1,69678011,7026.11
Huntington Beach1,64375611,3375.89
Riverside1,69678011,7026.21
Santa Clarita1,72479311,8966.28
755Jan756Feb969Mar1,071Apr1,058May1,124Jun1,184Jul1,198Aug1,047Sep924Oct794Nov687DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Who installs RECxxxAA Pure-RX-DC panels in SoCal

building permits · CSLB License Master
3
Permits naming this series
Jun 2026 – Aug 2026
1
Licensed installers
CSLB license on the permit
2
Jurisdictions so far
Chula Vista (2), LA County (unincorp.) (1)
Only installer and ZIP level is shown — no homeowner names, street addresses or permit numbers. Permits from LA County (unincorp.) come without a contractor license, so they count toward totals but not toward installers. Counts grow as more permit portals are loaded.

Installed together with

building permits

Microinverters

Enphase IQ8X
3

Batteries

Enphase IQ Battery 10C
3
Number of permits naming both this panel series and the product; 3 of 3 permits list other equipment.

Compare with similar 460 W panels

CEC PV Module List (Oct 7, 2026) · datasheets · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, ASizePVEL (product / brand)SoCal permits (series)
REC Group REC460AA Pure-RX-DC460 W≈22.8%−0.24865.78.88—brand 9×3
Aptos Solar DNA-120-MF10-460W460 W≈21.3%−0.36341.71475.1 × 44.6 in—22
Canadian Solar CS6.1-54TM-460H460 W≥22.5%−0.30839.314.6970.9 × 44.6 inproduct 2024, 20259
SEG Solar SEG-455-BTD-BG455 W≈23.3%−0.26239.7614.1167.8 × 44.6 inproduct 2023, 2024, 2025, 20268
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

About REC Group

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · RETC PV Module Index · building permits

Other series by SoCal permits

RECxxxAA Pure · 66RECxxxAA Pure-RX · 33RECxxxAA · 30RECxxxAA Black · 8RECxxxNP3 Black · 7RECxxxAA Pure 2 · 6

Questions & answers

How efficient is the REC Group REC460AA Pure-RX-DC?

Calculated from the panel area (2.02 m²): about 22.8% for the 460 W class. 460 W over 2.02 m² equals about 228 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 771 kWh per year per 460 W panel in Los Angeles and about 844 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.248 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 12.8% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–8 panels per string (Voc at 2 °C = 69.2 V, Vmp at 74 °C cell = 47.1 V). Final design must follow the inverter manual and NEC 690.7.

Does it work with Enphase IQ8X-80-M-US microinverters?

Voltage check against the Enphase datasheet: Voc when cold 69.2 V vs max input 79.5 V; Vmp when hot 47.1 V vs MPPT low 43 V; recommended module power 320–540 W. Confirm on the microinverter maker’s compatibility list.

Has this panel been reliability-tested?

This exact series is not in published PVEL Top Performer tables; REC Group was named a Top Performer in 9 Scorecards (2016–2025).

Who installs it in Southern California?

Building permits name this series 3 times (Jun 2026 – Aug 2026). The most active licensed installers are Stellar Solar Electric.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Aptos Solar — datasheet Legacy Products.
  3. Canadian Solar — datasheet TOPHiKu6 (All-Black) N-type TOPCon Technology CS6.1-54TM-435|440|445|450|455|460|465H.
  4. SEG Solar — manufacturer datasheet “XXXTFHTPMBSDPN YUKON/Series )BMG$FMM/5ZQF501$PO”.
  5. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2016–2025.
  6. RETC — PV Module Index reports 2023–2025.
  7. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  8. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  9. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  10. Building permits — City of Chula Vista (Jun 2026); Los Angeles County Public Works (EPIC-LA, unincorporated areas) (Aug 2026). Equipment matched from permit descriptions by model number.
  11. Contractors State License Board — License Master (contractor names and license status), as of Oct 5, 2026.
  12. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).