Cali-GrafCali-Graf
Solar panelREC Group

REC Group REC610AA Pro MG

120 half-cut cells, bifacial, white backsheet. Power classes 590–640 W in the CEC list.

CEC listed · Jun 3, 2024UL 61730BifacialPVEL Top Performer 2025
Power class
  • Power (STC)610 WCEC nameplate
  • Efficiency≈22.0%calculated from area
  • %/°C Pmax−0.233CEC listing test
  • PTC / STC95.3%PTC 582 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 6 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
REC590AA Pro MG590 W44.1017.3435.8016.50≈21.3%562 WJun 3, 2024
REC600AA Pro MG600 W44.2017.4536.0016.67≈21.7%572 WJun 3, 2024
REC610AA Pro MG610 W44.4017.5636.3016.81≈22.0%582 WJun 3, 2024
REC620AA Pro MG620 W44.6017.6736.6016.94≈22.4%591 WJun 3, 2024
REC630AA Pro MG630 W44.7017.7836.8017.12≈22.7%601 WJun 3, 2024
REC640AA Pro MG640 W44.9017.8937.1017.26≈23.1%611 WJun 3, 2024
≈ efficiency = Pmax ÷ CEC-listed area 2.77 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.233 %/°C
Voc coefficient β−0.232 %/°C
Isc coefficient α+0.044 %/°C
Operating cell temperatureNOCT 46.5 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
590 W440.4 W35.2 V × 12.51 A112.7 W95%
600 W447.5 W35.4 V × 12.64 A114.5 W95%
610 W455 W35.7 V × 12.75 A116.4 W95%
620 W462.3 W35.99 V × 12.85 A118.3 W95%
630 W469.8 W36.19 V × 12.98 A120.2 W95%
640 W477.5 W36.48 V × 13.09 A122.1 W95%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Certifications

CEC PV Module List (Oct 7, 2026) · Clean Energy Council (Australia)
UL 61730IEC 61215:2021 / IEC 61730:2016

Independent reliability testing

Kiwa PVEL Scorecard · RETC PV Module Index
2025
PVEL Top Performer
this series
1
Tests passed as Top Performer
PID
9
PVEL Scorecards
REC Group named Top Performer, 2016–2025
3
RETC PV Module Index
REC Group recognized 2023–2025

PVEL Top Performer tests

YearProductTests
2025RECxxxAA Pro MGPID

Tested bill of materials

Details describe the tested sample, not every module of the series.

RETC PV Module Index — REC Group

YearRecognition
2023High Achievement in Performance (Ptc-to-stc ratio, Module efficiency)
2024High Achievement in Performance
2025Test Category High Achiever

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
46.8 V
Voc when cold
per panel
31.4 V
Vmp when hot
per panel
12
Max panels / string
max DC 600 V
2
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet2–12
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–12
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–12
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window8–10

Microinverters (one per panel)

No microinverter in the reference set lists this power class in its recommended module power range.
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,6761,02211,2466.08
Palmdale1,8351,11912,3136.69
Chula Vista1,6961,03511,3806.11
Huntington Beach1,6431,00211,0255.89
Riverside1,6961,03511,3806.21
Santa Clarita1,7241,05211,5686.28
734Jan735Feb943Mar1,041Apr1,029May1,093Jun1,151Jul1,165Aug1,019Sep898Oct772Nov668DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 610 W panels

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · Canadian Solar datasheet
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)
REC Group REC610AA Pro MG610 W≈22%−0.23344.417.56product 2025
Phono Solar PS610M8GFH-24/TNH610 W≈23.8%−0.29353.814.02product 2024, 2025
ZNShine Solar ZXM7-UHLDD144-610/N610 W≈23.8%−0.28152.714.66product 2024, 2025, 2026
Canadian Solar CS6.2-66TB-610HP610 W≈22.6%−0.2824815.97brand 5× (2020–2026)
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

About REC Group

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · RETC PV Module Index · building permits

Other series by SoCal permits

RECxxxAA Pure · 66RECxxxAA Pure-RX · 33RECxxxAA · 30RECxxxAA Black · 8RECxxxNP3 Black · 7RECxxxAA Pure 2 · 6

Questions & answers

How efficient is the REC Group REC610AA Pro MG?

Calculated from the panel area (2.77 m²): about 22% for the 610 W class. 610 W over 2.77 m² equals about 220 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 1,022 kWh per year per 610 W panel in Los Angeles and about 1,119 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.233 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 12.1% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–12 panels per string (Voc at 2 °C = 46.8 V, Vmp at 74 °C cell = 31.4 V). Final design must follow the inverter manual and NEC 690.7.

Is it bifacial?

Yes. Rear gain depends on mounting height and ground reflectance.

Has this panel been reliability-tested?

RECxxxAA Pro MG was a PVEL Top Performer in 2025 (PID).

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Canadian Solar — datasheet TOPBiHiKu6 Anti-Hail N-type Bifacial TOPCon Technology.
  3. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2016–2025.
  4. RETC — PV Module Index reports 2023–2025.
  5. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  6. Clean Energy Council (Australia) — Approved PV modules list (as of Oct 8, 2026).
  7. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  8. Inverter datasheets — Solis (Ginlong), Tesla (manufacturer documents).
  9. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  10. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).