120 half-cut cells, HJT. Power classes 340–380 W in the CEC list.
| Model | Pmax | Voc, V | Isc, A | Vmp, V | Imp, A | Efficiency | PTC | CEC listed |
|---|---|---|---|---|---|---|---|---|
| REC340AA Black | 340 W | 43.10 | 10.09 | 36.40 | 9.34 | ≈20.1% | 321 W | Aug 15, 2019 |
| REC345AA Black | 345 W | 43.40 | 10.12 | 36.70 | 9.39 | ≈20.4% | 326 W | Aug 15, 2019 |
| REC350AA Black | 350 W | 43.20 | 10.44 | 36.00 | 9.73 | ≈20.7% | 331 W | Aug 15, 2019 |
| REC355AA Black | 355 W | 43.60 | 10.47 | 36.40 | 9.77 | ≈21.0% | 336 W | Aug 15, 2019 |
| REC360AA Black | 360 W | 43.90 | 10.49 | 36.70 | 9.82 | ≈21.3% | 341 W | Aug 15, 2019 |
| REC365AA Black | 365 W | 44.00 | 10.52 | 37.10 | 9.85 | ≈21.6% | 346 W | Aug 15, 2019 |
| REC370AA Black | 370 W | 44.10 | 10.55 | 37.40 | 9.90 | ≈21.9% | 351 W | Dec 11, 2020 |
| REC375AA Black | 375 W | 44.20 | 10.58 | 37.80 | 9.94 | ≈22.2% | 356 W | Dec 11, 2020 |
| REC380AA Black | 380 W | 44.30 | 10.61 | 38.10 | 9.98 | ≈22.5% | 360 W | Dec 11, 2020 |
| CEC listing test | |
|---|---|
| Pmax coefficient γ | −0.266 %/°C |
| Voc coefficient β | −0.235 %/°C |
| Isc coefficient α | +0.037 %/°C |
| Operating cell temperature | NOCT 46 °C |
| Class | Pmax at NOCT | Vmp × Imp at NOCT | Pmax at 200 W/m² | Low-light efficiency vs STC |
|---|---|---|---|---|
| 340 W | 252.4 W | 34.19 V × 7.38 A | 63.5 W | 93% |
| 345 W | 255.8 W | 34.47 V × 7.42 A | 64.4 W | 93% |
| 350 W | 251.7 W | 34.24 V × 7.35 A | 62.6 W | 89% |
| 355 W | 255.6 W | 34.62 V × 7.38 A | 63.5 W | 89% |
| 360 W | 259 W | 34.9 V × 7.42 A | 64.4 W | 89% |
| 365 W | 262.6 W | 35.28 V × 7.44 A | 65.3 W | 89% |
| 370 W | 266.1 W | 35.57 V × 7.48 A | 66.1 W | 89% |
| 375 W | 270 W | 35.95 V × 7.51 A | 67.1 W | 89% |
| 380 W | 273.2 W | 36.23 V × 7.54 A | 67.9 W | 89% |
| Year | Recognition |
|---|---|
| 2023 | High Achievement in Performance (Ptc-to-stc ratio, Module efficiency) |
| 2024 | High Achievement in Performance |
| 2025 | Test Category High Achiever |
| Inverter | Max DC input | MPPT | Window source | Panels per string |
|---|---|---|---|---|
| Tesla 1538000-xx-y | 600 V | 60–480 V | datasheet | 2–12 |
| Solis (Ginlong) S6-EH1P10K-H-US | 600 V | 80–520 V | datasheet | 3–12 |
| Solis (Ginlong) Solis-1P7.6K-4G-US | 600 V | 100–500 V | datasheet | 4–12 |
| Qcells Q.VOLT H7.6SX | 498 V | 234–498 V | CEC test window | 8–10 |
| Microinverter | Recommended module power | Max DC input | MPPT | Voc cold / Vmp hot | Check | DC/AC |
|---|---|---|---|---|---|---|
| Enphase IQ8PLUS-72-2-US | 235–440 W | 60 V | 29–45 V | 46.3 / 31.3 V | ✓ Within range | 1.24 |
| Enphase IQ8X-80-M-US | 320–540 W | 79.5 V | 43–60 V | 46.3 / 31.3 V | ✗ Not a match: module voltage below MPPT range | 0.95 |
| APsystems (Alt Power System) DS3-L | 265–570 W | 60 V | 28–45 V | 46.3 / 31.3 V | ✓ Within range | 0.46 |
| Enphase IQ8M-72-2-US | 260–460 W | 60 V | 30–45 V | 46.3 / 31.3 V | ✓ Within range | 1.11 |
| Enphase IQ8A-72-2-US | 295–500 W | 60 V | 32–45 V | 46.3 / 31.3 V | ⚠ Works; below MPPT at peak heat | 1.03 |
| City | kWh / kW / yr | kWh / panel / yr | kWh / system / yr | Sun, kWh/m²/day |
|---|---|---|---|---|
| Los Angeles | 1,676 | 603 | 11,464 | 6.08 |
| Palmdale | 1,835 | 661 | 12,551 | 6.69 |
| Chula Vista | 1,696 | 611 | 11,601 | 6.11 |
| Huntington Beach | 1,643 | 591 | 11,238 | 5.89 |
| Riverside | 1,696 | 611 | 11,601 | 6.21 |
| Santa Clarita | 1,724 | 621 | 11,792 | 6.28 |
| Panel | Pmax | Efficiency | γ Pmax (CEC) | Voc, V | Isc, A | PVEL (product / brand) | SoCal permits (series) |
|---|---|---|---|---|---|---|---|
| REC Group REC360AA Black | 360 W | ≈21.3% | −0.266 | 43.9 | 10.49 | brand 9× | 8 |
| LONGi LR4-60HPB-360M | 360 W | ≈20.3% | −0.339 | 40.8 | 11.33 | product 2021, 2022 | 193 |
| Trina Solar TSM-360DE06X.05(II) | 360 W | ≈19.8% | −0.339 | 44.8 | 10.3 | product 2022 | 23 |
| Qcells Q.PEAK DUO-G8+ 360 | 360 W | ≥20.1% | −0.343 | 41.19 | 10.84 | product 2022 | 20 |
Calculated from the panel area (1.69 m²): about 21.3% for the 360 W class. 360 W over 1.69 m² equals about 213 W per square meter.
PVWatts v8 with typical-year weather gives about 603 kWh per year per 360 W panel in Los Angeles and about 661 kWh in Palmdale (20° roof, facing south, 14% system losses).
With γ = −0.266 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 13.8% below the STC rating.
With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–12 panels per string (Voc at 2 °C = 46.3 V, Vmp at 74 °C cell = 31.3 V). Final design must follow the inverter manual and NEC 690.7.
Voltage check against the Enphase datasheet: Voc when cold 46.3 V vs max input 60 V; Vmp when hot 31.3 V vs MPPT low 29 V; recommended module power 235–440 W. Confirm on the microinverter maker’s compatibility list.
This exact series is not in published PVEL Top Performer tables; REC Group was named a Top Performer in 9 Scorecards (2016–2025).
Building permits name this series 8 times (Jul 2020 – Mar 2023). The most active licensed installers are Treepublic Solar.