144 half-cut cells, HJT. Power classes 420–450 W in the CEC list.
| Model | Pmax | Voc, V | Isc, A | Vmp, V | Imp, A | Efficiency | PTC | CEC listed |
|---|---|---|---|---|---|---|---|---|
| REC420AA 72 | 420 W | 52.50 | 10.20 | 44.50 | 9.45 | ≈20.4% | 398 W | Jul 13, 2020 |
| REC425AA 72 | 425 W | 52.60 | 10.23 | 44.80 | 9.49 | ≈20.6% | 403 W | Jul 13, 2020 |
| REC430AA 72 | 430 W | 52.70 | 10.25 | 45.10 | 9.54 | ≈20.9% | 408 W | Jul 13, 2020 |
| REC435AA 72 | 435 W | 52.90 | 10.27 | 45.40 | 9.59 | ≈21.1% | 412 W | Jul 13, 2020 |
| REC440AA 72 | 440 W | 53.00 | 10.31 | 45.70 | 9.63 | ≈21.4% | 417 W | Jul 13, 2020 |
| REC445AA 72 | 445 W | 53.20 | 10.38 | 46.00 | 9.68 | ≈21.6% | 422 W | Jul 13, 2020 |
| REC450AA 72 | 450 W | 53.20 | 10.43 | 46.30 | 9.72 | ≈21.9% | 427 W | Sep 1, 2020 |
| CEC listing test | |
|---|---|
| Pmax coefficient γ | −0.272 %/°C |
| Voc coefficient β | −0.235 %/°C |
| Isc coefficient α | +0.029 %/°C |
| Operating cell temperature | NOCT 45.2 °C |
| Class | Pmax at NOCT | Vmp × Imp at NOCT | Pmax at 200 W/m² | Low-light efficiency vs STC |
|---|---|---|---|---|
| 420 W | 315.3 W | 41.4 V × 7.62 A | 80.1 W | 95% |
| 425 W | 318.8 W | 41.68 V × 7.65 A | 81 W | 95% |
| 430 W | 322.6 W | 41.96 V × 7.69 A | 82 W | 95% |
| 435 W | 326.4 W | 42.24 V × 7.73 A | 83 W | 95% |
| 440 W | 330 W | 42.52 V × 7.76 A | 83.9 W | 95% |
| 445 W | 333.9 W | 42.8 V × 7.8 A | 84.8 W | 95% |
| 450 W | 337.4 W | 43.08 V × 7.83 A | 85.8 W | 95% |
| Year | Recognition |
|---|---|
| 2023 | High Achievement in Performance (Ptc-to-stc ratio, Module efficiency) |
| 2024 | High Achievement in Performance |
| 2025 | Test Category High Achiever |
| Inverter | Max DC input | MPPT | Window source | Panels per string |
|---|---|---|---|---|
| Tesla 1538000-xx-y | 600 V | 60–480 V | datasheet | 2–10 |
| Solis (Ginlong) S6-EH1P10K-H-US | 600 V | 80–520 V | datasheet | 3–10 |
| Solis (Ginlong) Solis-1P7.6K-4G-US | 600 V | 100–500 V | datasheet | 3–10 |
| Qcells Q.VOLT H7.6SX | 498 V | 234–498 V | CEC test window | 6–8 |
| Microinverter | Recommended module power | Max DC input | MPPT | Voc cold / Vmp hot | Check | DC/AC |
|---|---|---|---|---|---|---|
| Enphase IQ8X-80-M-US | 320–540 W | 79.5 V | 43–60 V | 56.1 / 39.2 V | ⚠ Works; below MPPT at peak heat | 1.17 |
| APsystems (Alt Power System) DS3-L | 265–570 W | 60 V | 28–45 V | 56.1 / 39.2 V | ✓ Within range | 0.57 |
| Enphase IQ8M-72-2-US | 260–460 W | 60 V | 30–45 V | 56.1 / 39.2 V | ✓ Within range | 1.37 |
| Enphase IQ8A-72-2-US | 295–500 W | 60 V | 32–45 V | 56.1 / 39.2 V | ✓ Within range | 1.28 |
| City | kWh / kW / yr | kWh / panel / yr | kWh / system / yr | Sun, kWh/m²/day |
|---|---|---|---|---|
| Los Angeles | 1,676 | 746 | 11,933 | 6.08 |
| Palmdale | 1,835 | 817 | 13,065 | 6.69 |
| Chula Vista | 1,696 | 755 | 12,076 | 6.11 |
| Huntington Beach | 1,643 | 731 | 11,698 | 5.89 |
| Riverside | 1,696 | 755 | 12,076 | 6.21 |
| Santa Clarita | 1,724 | 767 | 12,275 | 6.28 |
| Panel | Pmax | Efficiency | γ Pmax (CEC) | Voc, V | Isc, A | Warranty | PVEL (product / brand) | SoCal permits (series) |
|---|---|---|---|---|---|---|---|---|
| REC Group REC445AA 72 | 445 W | ≈21.6% | −0.272 | 53.2 | 10.38 | — | brand 9× | 3 |
| Qcells Q.TRON BLK M-G2+ 445 | 445 W | ≈22.8% | −0.276 | 40.16 | 13.98 | 25 / 25 yr | brand 11× (2016–2026) | 40 |
| Silfab Solar SIL-440QD | 440 W | ≈22.6% | −0.294 | 38.97 | 14.25 | 25 / 30 yr | brand 7× (2017–2025) | 39 |
| Hyundai Energy Solutions HiN-T445NF(BK) | 445 W | ≈22.9% | −0.298 | 39 | 14.46 | 25 / 30 yr | brand 5× (2017–2025) | 37 |
Calculated from the panel area (2.06 m²): about 21.6% for the 445 W class. 445 W over 2.06 m² equals about 216 W per square meter.
PVWatts v8 with typical-year weather gives about 746 kWh per year per 445 W panel in Los Angeles and about 817 kWh in Palmdale (20° roof, facing south, 14% system losses).
With γ = −0.272 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 14.1% below the STC rating.
With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–10 panels per string (Voc at 2 °C = 56.1 V, Vmp at 74 °C cell = 39.2 V). Final design must follow the inverter manual and NEC 690.7.
Voltage check against the APsystems (Alt Power System) datasheet: Voc when cold 56.1 V vs max input 60 V; Vmp when hot 39.2 V vs MPPT low 28 V; recommended module power 265–570 W. Confirm on the microinverter maker’s compatibility list.
This exact series is not in published PVEL Top Performer tables; REC Group was named a Top Performer in 9 Scorecards (2016–2025).
Building permits name this series 3 times (Jan 2021 – Jun 2021). The most active licensed installers are N R G Clean Power Inc.