Cali-GrafCali-Graf
AC solar panelQcells

Qcells Q.TRON BLK M-G2.F1+/AC 420

108 half-cut cells. Power classes 405–440 W in the CEC list.

CEC listed · Dec 22, 2025UL 1741AC module · built-in microinverter
Power class
  • Power (STC)420 WCEC nameplate
  • Efficiency≈22.1%calculated from area
  • %/°C Pmax−0.314CEC listing test
  • PTC / STC93.8%PTC 394 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 8 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
Q.TRON BLK M-G2.F1+/AC 405405 W37.9113.3331.9312.69≈21.3%380 WDec 22, 2025
Q.TRON BLK M-G2.F1+/AC 410410 W38.1913.4132.1312.76≈21.6%384 WDec 22, 2025
Q.TRON BLK M-G2.F1+/AC 415415 W38.4713.4932.3412.83≈21.8%389 WDec 22, 2025
Q.TRON BLK M-G2.F1+/AC 420420 W38.7513.5832.5412.91≈22.1%394 WDec 22, 2025
Q.TRON BLK M-G2.F1+/AC 425425 W39.0313.6632.7412.98≈22.4%399 WDec 22, 2025
Q.TRON BLK M-G2.F1+/AC 430430 W39.3213.7432.9413.05≈22.6%404 WDec 22, 2025
Q.TRON BLK M-G2.F1+/AC 435435 W39.6013.8233.1413.13≈22.9%409 WDec 22, 2025
Q.TRON BLK M-G2.F1+/AC 440440 W39.8813.9033.3313.20≈23.2%413 WDec 22, 2025
≈ efficiency = Pmax ÷ CEC-listed area 1.9 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.314 %/°C
Voc coefficient β−0.245 %/°C
Isc coefficient α+0.036 %/°C
Operating cell temperatureNOCT 46.1 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
405 W299.3 W30.02 V × 9.97 A76.4 W94%
410 W302.8 W30.21 V × 10.03 A77.3 W94%
415 W306.5 W30.41 V × 10.08 A78.2 W94%
420 W310.3 W30.59 V × 10.14 A79.2 W94%
425 W313.9 W30.78 V × 10.2 A80.1 W94%
430 W317.5 W30.97 V × 10.25 A81.1 W94%
435 W321.4 W31.16 V × 10.32 A82 W94%
440 W325 W31.34 V × 10.37 A83 W94%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Independent reliability testing

Kiwa PVEL Scorecard · RETC PV Module Index
11
PVEL Scorecards
Qcells named Top Performer, 2016–2026
2023, 2026
RETC Overall Highest Achiever
Qcells, manufacturer level
This exact series is not listed in published PVEL Top Performer tables. Results below are for the manufacturer.

RETC PV Module Index — Qcells

YearRecognition
2023Overall Highest Achiever; High Achievement in Performance (Module efficiency, Pan file performance); High Achievement in Reliability (Damp heat test, Pid resistance, Thermal cycle test)
2024High Achievement in Performance
2025Performance High Achiever
2026Overall Highest Achiever; High achievement in performance; High achievement in reliability; Performance discipline high achiever (Conversion efficiency, Iam, Letid, Lid, PTC-to-STC, Temperature coefficient); Quality discipline high achiever (BOM verification); Reliability discipline high achiever (Sdml, Tc, Uvid, Budt, Damp heat, Hdt, Pid)

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67670411,9676.08
Palmdale1,83577113,1026.69
Chula Vista1,69671212,1096.11
Huntington Beach1,64369011,7315.89
Riverside1,69671212,1096.21
Santa Clarita1,72472412,3096.28
781Jan782Feb1,003Mar1,108Apr1,095May1,163Jun1,225Jul1,240Aug1,084Sep956Oct822Nov711DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

About Qcells

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · RETC PV Module Index · building permits

Other series by SoCal permits

Q.PEAK DUO BLK ML-G10+ · 221Q.PEAK DUO BLK ML-G10.C+ · 124Q.TRON BLK M-G2+ · 40Q.TRON BLK M-G2.H+ · 33Q.TRON BLK M-G2.C+ · 24Q.TRON M-G2+ · 20

Questions & answers

How efficient is the Qcells Q.TRON BLK M-G2.F1+/AC 420?

Calculated from the panel area (1.9 m²): about 22.1% for the 420 W class. 420 W over 1.9 m² equals about 221 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 704 kWh per year per 420 W panel in Los Angeles and about 771 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.314 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 16.3% below the STC rating.

Has this panel been reliability-tested?

This exact series is not in published PVEL Top Performer tables; Qcells was named a Top Performer in 11 Scorecards (2016–2026). RETC named Qcells Overall Highest Achiever in 2023, 2026.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List (snapshot Oct 7, 2026).
  2. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2016–2026.
  3. RETC — PV Module Index reports 2023–2026.
  4. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  5. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  6. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).