Cali-GrafCali-Graf
Solar panelQcells

Qcells Q.PEAK DUO XL-G9.2 450

156 half-cut cells. Power classes 430–470 W in the CEC list.

CEC listed · Oct 12, 2020UL 61730
Power class
  • Power (STC)450 WCEC nameplate
  • Efficiency≈21.0%calculated from area
  • %/°C Pmax−0.364CEC listing test
  • PTC / STC92.6%PTC 417 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 9 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
Q.PEAK DUO XL-G9.2 430430 W53.0410.5443.209.95≈20.1%398 WOct 12, 2020
Q.PEAK DUO XL-G9.2 435435 W53.0710.5743.4910.00≈20.3%402 WOct 12, 2020
Q.PEAK DUO XL-G9.2 440440 W53.1110.5943.7710.05≈20.6%407 WOct 12, 2020
Q.PEAK DUO XL-G9.2 445445 W53.1510.6244.0610.10≈20.8%412 WOct 12, 2020
Q.PEAK DUO XL-G9.2 450450 W53.1810.6544.3410.15≈21.0%417 WOct 12, 2020
Q.PEAK DUO XL-G9.2 455455 W53.2210.6744.6110.20≈21.3%421 WOct 12, 2020
Q.PEAK DUO XL-G9.2 460460 W53.2510.7044.8910.25≈21.5%426 WOct 12, 2020
Q.PEAK DUO XL-G9.2 465465 W53.2910.7345.1610.30≈21.7%431 WOct 12, 2020
Q.PEAK DUO XL-G9.2 470470 W53.3310.7545.4310.35≈22.0%436 WOct 12, 2020
≈ efficiency = Pmax ÷ CEC-listed area 2.14 m².
CEC note: Formerly listed under Hanwha Q CELLS

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.364 %/°C
Voc coefficient β−0.259 %/°C
Isc coefficient α+0.017 %/°C
Operating cell temperatureNOCT 46.5 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
430 W312 W39.49 V × 7.9 A85.1 W99%
435 W315.7 W39.75 V × 7.94 A86.1 W99%
440 W319.3 W40.01 V × 7.98 A87 W99%
445 W323 W40.27 V × 8.02 A88.1 W99%
450 W326.7 W40.53 V × 8.06 A89.1 W99%
455 W330.3 W40.78 V × 8.1 A90 W99%
460 W334 W41.03 V × 8.14 A91 W99%
465 W337.6 W41.28 V × 8.18 A92 W99%
470 W341.3 W41.53 V × 8.22 A93 W99%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Independent reliability testing

Kiwa PVEL Scorecard · RETC PV Module Index
11
PVEL Scorecards
Qcells named Top Performer, 2016–2026
2023, 2026
RETC Overall Highest Achiever
Qcells, manufacturer level
This exact series is not listed in published PVEL Top Performer tables. Results below are for the manufacturer.

RETC PV Module Index — Qcells

YearRecognition
2023Overall Highest Achiever; High Achievement in Performance (Module efficiency, Pan file performance); High Achievement in Reliability (Damp heat test, Pid resistance, Thermal cycle test)
2024High Achievement in Performance
2025Performance High Achiever
2026Overall Highest Achiever; High achievement in performance; High achievement in reliability; Performance discipline high achiever (Conversion efficiency, Iam, Letid, Lid, PTC-to-STC, Temperature coefficient); Quality discipline high achiever (BOM verification); Reliability discipline high achiever (Sdml, Tc, Uvid, Budt, Damp heat, Hdt, Pid)

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
56.4 V
Voc when cold
per panel
36.1 V
Vmp when hot
per panel
10
Max panels / string
max DC 600 V
2
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet2–10
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–10
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet3–10
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window7–8

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V56.4 / 36.1 V⚠ Works; below MPPT at peak heat1.18
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V56.4 / 36.1 V✓ Within range0.58
Enphase IQ8M-72-2-US260–460 W60 V30–45 V56.4 / 36.1 V✓ Within range1.38
Enphase IQ8A-72-2-US295–500 W60 V32–45 V56.4 / 36.1 V✓ Within range1.29
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67675412,0676.08
Palmdale1,83582613,2126.69
Chula Vista1,69676312,2116.11
Huntington Beach1,64373911,8305.89
Riverside1,69676312,2116.21
Santa Clarita1,72477612,4136.28
788Jan788Feb1,012Mar1,117Apr1,104May1,173Jun1,236Jul1,250Aug1,093Sep964Oct829Nov717DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 450 W panels

CEC PV Module List (Oct 7, 2026) · datasheets · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
Qcells Q.PEAK DUO XL-G9.2 450450 W≈21%−0.36453.1810.65brand 11×—
Hyundai Energy Solutions HiN-T450NF(BK)450 W≈23.2%−0.29839.214.53brand 5× (2017–2025)37
REC Group REC450AA Pure-RX450 W≈22.3%−0.24865.18.81brand 9× (2016–2025)33
Aptos Solar DNA-120-MF10-450W450 W≥20.8%−0.35541.1813.85—22
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

About Qcells

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · RETC PV Module Index · building permits

Other series by SoCal permits

Q.PEAK DUO BLK ML-G10+ · 221Q.PEAK DUO BLK ML-G10.C+ · 124Q.TRON BLK M-G2+ · 40Q.TRON BLK M-G2.H+ · 33Q.TRON BLK M-G2.C+ · 24Q.TRON M-G2+ · 20

Questions & answers

How efficient is the Qcells Q.PEAK DUO XL-G9.2 450?

Calculated from the panel area (2.14 m²): about 21% for the 450 W class. 450 W over 2.14 m² equals about 210 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 754 kWh per year per 450 W panel in Los Angeles and about 826 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.364 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 18.9% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–10 panels per string (Voc at 2 °C = 56.4 V, Vmp at 74 °C cell = 36.1 V). Final design must follow the inverter manual and NEC 690.7.

Does it work with APsystems (Alt Power System) DS3-L microinverters?

Voltage check against the APsystems (Alt Power System) datasheet: Voc when cold 56.4 V vs max input 60 V; Vmp when hot 36.1 V vs MPPT low 28 V; recommended module power 265–570 W. Confirm on the microinverter maker’s compatibility list.

Has this panel been reliability-tested?

This exact series is not in published PVEL Top Performer tables; Qcells was named a Top Performer in 11 Scorecards (2016–2026). RETC named Qcells Overall Highest Achiever in 2023, 2026.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Hyundai Energy Solutions — datasheet [US] NF(BK)(HiN) Series (N TOPCon Bifacial) 435~445W.
  3. Aptos Solar — datasheet Legacy Products.
  4. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2016–2026.
  5. RETC — PV Module Index reports 2023–2026.
  6. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  7. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  8. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  9. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  10. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).