156 half-cut cells (6 × 26). Power classes 460–505 W in the CEC list; datasheet covers 475–495 W.
| Model | Pmax | Voc, V | Isc, A | Vmp, V | Imp, A | Efficiency | PTC | CEC listed |
|---|---|---|---|---|---|---|---|---|
| Q.PEAK DUO XL-G10.d 460 | 460 W | 53.48 | 11.16 | 43.73 | 10.52 | ≈19.9% | 428 W | Jul 1, 2021 |
| Q.PEAK DUO XL-G10.d 465 | 465 W | 53.51 | 11.18 | 44.00 | 10.57 | ≈20.1% | 433 W | Jul 1, 2021 |
| Q.PEAK DUO XL-G10.d 470 | 470 W | 53.54 | 11.21 | 44.27 | 10.62 | ≈20.3% | 438 W | Jul 1, 2021 |
| Q.PEAK DUO XL-G10.d 475 | 475 W | 53.58 | 11.24 | 44.54 | 10.66 | ≥20.5% | 442 W | Jul 1, 2021 |
| Q.PEAK DUO XL-G10.d 480 | 480 W | 53.61 | 11.26 | 44.81 | 10.71 | ≥20.7% | 447 W | Jul 1, 2021 |
| Q.PEAK DUO XL-G10.d 485 | 485 W | 53.64 | 11.29 | 45.07 | 10.76 | ≥20.9% | 452 W | Jul 1, 2021 |
| Q.PEAK DUO XL-G10.d 490 | 490 W | 53.68 | 11.31 | 45.33 | 10.81 | ≥21.2% | 457 W | Jul 1, 2021 |
| Q.PEAK DUO XL-G10.d 495 | 495 W | 53.71 | 11.34 | 45.59 | 10.86 | ≥21.4% | 462 W | Jul 1, 2021 |
| Q.PEAK DUO XL-G10.d 500 | 500 W | 53.75 | 11.36 | 45.85 | 10.91 | ≈21.6% | 466 W | Jul 1, 2021 |
| Q.PEAK DUO XL-G10.d 505 | 505 W | 53.78 | 11.39 | 46.10 | 10.95 | ≈21.8% | 471 W | Jul 1, 2021 |
| Datasheet | CEC listing test | |
|---|---|---|
| Pmax coefficient γ | −0.34 %/°C | −0.340 %/°C |
| Voc coefficient β | −0.27 %/°C | −0.264 %/°C |
| Isc coefficient α | +0.04 %/°C | +0.013 %/°C |
| Vmp coefficient | ≈ −0.38 %/°C | — |
| Operating cell temperature | NMOT 43 ± 3 °C | NOCT 46.5 °C |
| Class | Pmax, W | Voc, V | Isc, A | Vmp, V | Imp, A |
|---|---|---|---|---|---|
| 475 W | 356.4 | 50.53 | 9.05 | 42.49 | 8.39 |
| 480 W | 360.1 | 50.56 | 9.07 | 42.72 | 8.43 |
| 485 W | 363.9 | 50.59 | 9.09 | 42.94 | 8.47 |
| 490 W | 367.6 | 50.62 | 9.12 | 43.17 | 8.52 |
| 495 W | 371.4 | 50.65 | 9.14 | 43.39 | 8.56 |
| Class | Pmax at NOCT | Vmp × Imp at NOCT | Pmax at 200 W/m² | Low-light efficiency vs STC |
|---|---|---|---|---|
| 460 W | 338 W | 40.53 V × 8.34 A | 87.4 W | 95% |
| 465 W | 341.7 W | 40.78 V × 8.38 A | 88.4 W | 95% |
| 470 W | 345.4 W | 41.03 V × 8.42 A | 89.3 W | 95% |
| 475 W | 348.8 W | 41.28 V × 8.45 A | 90.2 W | 95% |
| 480 W | 352.6 W | 41.53 V × 8.49 A | 91.2 W | 95% |
| 485 W | 356.3 W | 41.77 V × 8.53 A | 92.2 W | 95% |
| 490 W | 360 W | 42.01 V × 8.57 A | 93.1 W | 95% |
| 495 W | 363.8 W | 42.25 V × 8.61 A | 94.1 W | 95% |
| 500 W | 367.5 W | 42.49 V × 8.65 A | 95.1 W | 95% |
| 505 W | 370.9 W | 42.73 V × 8.68 A | 95.9 W | 95% |
| Year | Product | Tests |
|---|---|---|
| 2023 | Q.PEAK DUO XL-G10.d | LID+LETIDPID |
| Year | Recognition |
|---|---|
| 2023 | Overall Highest Achiever; High Achievement in Performance (Module efficiency, Pan file performance); High Achievement in Reliability (Damp heat test, Pid resistance, Thermal cycle test) |
| 2024 | High Achievement in Performance |
| 2025 | Performance High Achiever |
| 2026 | Overall Highest Achiever; High achievement in performance; High achievement in reliability; Performance discipline high achiever (Conversion efficiency, Iam, Letid, Lid, PTC-to-STC, Temperature coefficient); Quality discipline high achiever (BOM verification); Reliability discipline high achiever (Sdml, Tc, Uvid, Budt, Damp heat, Hdt, Pid) |
| Inverter | Max DC input | MPPT | Window source | Panels per string |
|---|---|---|---|---|
| Tesla 1538000-xx-y | 600 V | 60–480 V | datasheet | 2–10 |
| Solis (Ginlong) S6-EH1P10K-H-US | 600 V | 80–520 V | datasheet | 3–10 |
| Solis (Ginlong) Solis-1P7.6K-4G-US | 600 V | 100–500 V | datasheet | 3–10 |
| Qcells Q.VOLT H7.6SX | 498 V | 234–498 V | CEC test window | 7–8 |
| Microinverter | Recommended module power | Max DC input | MPPT | Voc cold / Vmp hot | Check | DC/AC |
|---|---|---|---|---|---|---|
| Enphase IQ8X-80-M-US | 320–540 W | 79.5 V | 43–60 V | 57 / 36.7 V | ⚠ Works; below MPPT at peak heat | 1.28 |
| APsystems (Alt Power System) DS3-L | 265–570 W | 60 V | 28–45 V | 57 / 36.7 V | ✓ Within range | 0.62 |
| Enphase IQ8A-72-2-US | 295–500 W | 60 V | 32–45 V | 57 / 36.7 V | ✓ Within range | 1.39 |
| City | kWh / kW / yr | kWh / panel / yr | kWh / system / yr | Sun, kWh/m²/day |
|---|---|---|---|---|
| Los Angeles | 1,676 | 813 | 11,380 | 6.08 |
| Palmdale | 1,835 | 890 | 12,460 | 6.69 |
| Chula Vista | 1,696 | 823 | 11,516 | 6.11 |
| Huntington Beach | 1,643 | 797 | 11,156 | 5.89 |
| Riverside | 1,696 | 823 | 11,516 | 6.21 |
| Santa Clarita | 1,724 | 836 | 11,706 | 6.28 |
median 99.9 kW, 206 panels (n = 5)
| Panel | Pmax | Efficiency | γ Pmax (CEC) | Voc, V | Isc, A | SoCal permits (series) |
|---|---|---|---|---|---|---|
| Qcells Q.PEAK DUO XL-G10.d 485 | 485 W | ≥20.9% | −0.340 | 53.64 | 11.29 | 6 |
| SEG Solar SEG-495-BTD-BG | 495 W | ≈25.3% | −0.290 | 39.9 | 15.82 | 8 |
| AXITEC AC-450MH/144V | 450 W | ≈21.2% | −0.380 | 50 | 11.47 | 1 |
| La Solar LS450BL | 450 W | ≈20.5% | −0.352 | 49.6 | 11.53 | 1 |
The Qcells datasheet guarantees at least 20.9% module efficiency for the 485 W class (up to 21.4% for 495 W). 485 W over 2.32 m² equals about 209 W per square meter.
PVWatts v8 with typical-year weather gives about 813 kWh per year per 485 W panel in Los Angeles and about 890 kWh in Palmdale (20° roof, facing south, 14% system losses).
With γ = −0.34 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 17.6% below the STC rating.
With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–10 panels per string (Voc at 2 °C = 57 V, Vmp at 74 °C cell = 36.7 V). Final design must follow the inverter manual and NEC 690.7.
Voltage check against the APsystems (Alt Power System) datasheet: Voc when cold 57 V vs max input 60 V; Vmp when hot 36.7 V vs MPPT low 28 V; recommended module power 265–570 W. Confirm on the microinverter maker’s compatibility list.
12 years on the product and 25 years linear on performance: at least 86% after 25 years (manufacturer datasheet).
87.2 × 41.1 × 1.38 in (2,216 × 1,045 × 35 mm), 57.3 lb (26 kg).
Q.PEAK DUO XL-G10.d was a PVEL Top Performer in 2023 (LID+LETID, PID).