Overall Highest Achiever; High achievement in performance; High achievement in reliability; Performance discipline high achiever (Conversion efficiency, Iam, Letid, Lid, PTC-to-STC, Temperature coefficient); Quality discipline high achiever (BOM verification); Reliability discipline high achiever (Sdml, Tc, Uvid, Budt, Damp heat, Hdt, Pid)
Inverter compatibility & string sizing
Qcells datasheet · Cali-Graf calculation · NLR PVWatts v8 · CEC PV Module List (Oct 7, 2026) · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
57 V
Voc when cold
per panel
36.7 V
Vmp when hot
per panel
10
Max panels / string
max DC 600 V
2
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above.
String inverters most named in SoCal permits
Inverter
Max DC input
MPPT
Window source
Panels per string
Tesla 1538000-xx-y
600 V
60–480 V
datasheet
2–10
Solis (Ginlong) S6-EH1P10K-H-US
600 V
80–520 V
datasheet
3–10
Solis (Ginlong) Solis-1P7.6K-4G-US
600 V
100–500 V
datasheet
3–10
Qcells Q.VOLT H7.6SX
498 V
234–498 V
CEC test window
7–8
Microinverters (one per panel)
Microinverter
Recommended module power
Max DC input
MPPT
Voc cold / Vmp hot
Check
DC/AC
Enphase IQ8X-80-M-US
320–540 W
79.5 V
43–60 V
57 / 36.7 V
⚠ Works; below MPPT at peak heat
1.28
APsystems (Alt Power System) DS3-L
265–570 W
60 V
28–45 V
57 / 36.7 V
✓ Within range
0.62
Enphase IQ8A-72-2-US
295–500 W
60 V
32–45 V
57 / 36.7 V
✓ Within range
1.39
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.
Expected production in Southern California
NLR PVWatts v8 · Cali-Graf calculation
City
kWh / kW / yr
kWh / panel / yr
kWh / system / yr
Sun, kWh/m²/day
Los Angeles
1,676
813
11,380
6.08
Palmdale
1,835
890
12,460
6.69
Chula Vista
1,696
823
11,516
6.11
Huntington Beach
1,643
797
11,156
5.89
Riverside
1,696
823
11,516
6.21
Santa Clarita
1,724
836
11,706
6.28
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.
Compare with similar 485 W panels
CEC PV Module List (Oct 7, 2026) · datasheets · Kiwa PVEL Scorecard · building permits
Panel
Pmax
Efficiency
γ Pmax (CEC)
Voc, V
Isc, A
SoCal permits (series)
Qcells Q.PEAK DUO XL-G10.2 485
485 W
≥20.9%
−0.340
53.64
11.29
1
SEG Solar SEG-495-BTD-BG
495 W
≈25.3%
−0.290
39.9
15.82
8
AXITEC AC-450MH/144V
450 W
≈21.2%
−0.380
50
11.47
1
La Solar LS450BL
450 W
≈20.5%
−0.352
49.6
11.53
1
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.
About Qcells
CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · RETC PV Module Index · building permits
ManufacturerQcells
Listed in CEC asHanwha Qcells (Qidong) Co. Ltd., Qcells North America
How efficient is the Qcells Q.PEAK DUO XL-G10.2 485?
The Qcells datasheet guarantees at least 20.9% module efficiency for the 485 W class (up to 21.4% for 495 W). 485 W over 2.22 m² equals about 218 W per square meter.
How much energy does one panel produce in Los Angeles or Palmdale?
PVWatts v8 with typical-year weather gives about 813 kWh per year per 485 W panel in Los Angeles and about 890 kWh in Palmdale (20° roof, facing south, 14% system losses).
How much power does it lose on a hot roof?
With γ = −0.34 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 17.6% below the STC rating.
How many panels fit on one string?
With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–10 panels per string (Voc at 2 °C = 57 V, Vmp at 74 °C cell = 36.7 V). Final design must follow the inverter manual and NEC 690.7.
Does it work with APsystems (Alt Power System) DS3-L microinverters?
Voltage check against the APsystems (Alt Power System) datasheet: Voc when cold 57 V vs max input 60 V; Vmp when hot 36.7 V vs MPPT low 28 V; recommended module power 265–570 W. Confirm on the microinverter maker’s compatibility list.
What does the warranty cover?
12 years on the product and 25 years linear on performance: at least 98% of rated power in year 1, then no more than 0.5% per year — at least 86% after 25 years (manufacturer datasheet).
Has this panel been reliability-tested?
Q.PEAK DUO XL-G10.2 was a PVEL Top Performer in 2023 (LID+LETID).
What fire rating does it have?
UL 61730 fire rating Type 1 per datasheet.
Sources
California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
Qcells — manufacturer datasheet “Q.PEAK DUO XL-G10.2 ENDURING HIGH PERFORMANCE”.
SEG Solar — manufacturer datasheet “XXXTFHTPMBSDPN YUKON/Series )BMG$FMM/5ZQF501$PO”.
NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
Building permits — Los Angeles County Public Works (EPIC-LA, unincorporated areas) (Feb 2023). Equipment matched from permit descriptions by model number.
Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).
Get your free estimate
Three fields, and Cali Energy calls back within 30 minutes during business hours.
Thanks!
We got your request and will call back within 30 minutes during business hours.